Two-stage Optimal Dispatching of AC/DC Hybrid Active Distribution Systems Considering Network Flexibility

被引:59
|
作者
Su, Yi [1 ]
Teh, Jiashen [1 ]
机构
[1] Univ Sains Malaysia USM, Sch Elect & Elect Engn, Nibong Tebal 14300, Penang, Malaysia
关键词
Dispatching; Uncertainty; Real-time systems; Programming; Optimal scheduling; Reactive power; Hybrid power systems; Two-stage dispatching; network flexibility; renewable distributed generator; second-order cone programming (SOCP); alternating current (AC)/direct current (DC) hybrid active distribution system; RENEWABLE ENERGY-SOURCES; OPTIMAL POWER-FLOW; VOLTAGE-CONTROL; REACTIVE POWER; RECONFIGURATION; UNCERTAINTY; RELAXATION; MANAGEMENT; SCHEME; LOADS;
D O I
10.35833/MPCE.2022.000424
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The increasing flexibility of active distribution systems (ADSs) coupled with the high penetration of renewable distributed generators (RDGs) leads to the increase of the complexity. It is of practical significance to achieve the largest amount of RDG penetration in ADSs and maintain the optimal operation. This study establishes an alternating current (AC)/direct current (DC) hybrid ADS model that considers the dynamic thermal rating, soft open point, and distribution network reconfiguration (DNR). Moreover, it transforms the optimal dispatching into a second-order cone programming problem. Considering the different control time scales of dispatchable resources, the following two-stage dispatching framework is proposed. ? The day-ahead dispatch uses hourly input data with the goal of minimizing the grid loss and RDG dropout. It obtains the optimal 24-hour schedule to determine the dispatching plans for DNR and the energy storage system. ? The intraday dispatch uses 15 min of input data for 1-hour rolling-plan dispatch but only executes the first 15 min of dispatching. To eliminate error between the actual operation and dispatching plan, the first 15 min is divided into three 5-min step-by-step executions. The goal of each step is to trace the tie-line power of the intraday rolling-plan dispatch to the greatest extent at the minimum cost. The measured data are used as feedback input for the rolling-plan dispatch after each step is executed. A case study shows that the comprehensive cooperative ADS model can release the line capacity, reduce losses, and improve the penetration rate of RDGs. Further, the two-stage dispatching frame-work can handle source-load fluctuations and enhance system stability.
引用
收藏
页码:52 / 65
页数:14
相关论文
共 50 条
  • [1] Two-stage Optimal Dispatching of AC/DC Hybrid Active Distribution Systems Considering Network Flexibility
    Yi Su
    Jiashen Teh
    Journal of Modern Power Systems and Clean Energy, 2023, 11 (01) : 52 - 65
  • [2] Two-stage Optimal Dispatching Method for Distribution System Flexibility Improvement Considering Dynamic Reconfiguration
    Wu Z.
    Qin C.
    Yu Y.
    Dianwang Jishu/Power System Technology, 2020, 44 (12): : 4644 - 4653
  • [3] Two-Stage Active and Reactive Power Coordinated Optimal Dispatch for Active Distribution Network Considering Load Flexibility
    Zhang, Yu
    Song, Xiaohui
    Li, Yong
    Zeng, Zilong
    Yong, Chenchen
    Sidorov, Denis
    Lv, Xia
    ENERGIES, 2020, 13 (22)
  • [4] Multidimensional coordinated optimal dispatching method for AC/DC hybrid distribution network
    Wang, X.H. (wangxiaohui@epri.sgcc.com.cn), 1600, AMSE Press, 16 Avenue Grauge Blanche, Tassin-la-Demi-Lune, 69160, France (89):
  • [5] A Two-stage Reactive Power Optimization Strategy for AC/DC Hybrid Distribution Network
    Li, Chao
    Miao, Shihong
    Zhang, Di
    Li, Lixing
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 426 - 431
  • [6] Two-Stage Uncertain Optimal Scheduling of Active Distribution Network Considering Operational Risk
    Dong, Lei
    Zhao, Can
    Chen, Naishi
    Li, Ye
    Pu, Tianjiao
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 1699 - 1703
  • [7] Two-Stage Stochastic Programming Scheduling Model for Hybrid AC/DC Distribution Network Considering Converters and Energy Storage System
    Kang, Peng
    Guo, Wei
    Huang, Weigang
    Qiu, Zejing
    Yu, Meng
    Zheng, Feng
    Zhang, Yachao
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [8] A Two-Stage Protection Scheme Based on Control and Protection Coordination for AC/DC Hybrid Distribution Network
    Qian, Zhonghao
    Yuan, Yubo
    Li, Juan
    Dong, Hao
    Qin, Ting
    Huang, Xuan
    Lyu, Pengpeng
    Jiang, Yunlong
    Wang, Jiaming
    IEEE ACCESS, 2024, 12 : 132533 - 132542
  • [9] A two-layer two-stage dispatching strategy for active distribution network with micro-grid considering multiple interactions
    Xu, Yan
    Zhang, Jianhao
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 187
  • [10] A Flexibility Planning Method for Hybrid AC / DC Distribution Network
    Cai, Hui
    Sun, Zhihuang
    Xu, Haihua
    Xi, Weimin
    Fan, Anjie
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,