Design of customized implants and 3D printing of symmetric and asymmetric cranial cavities

被引:5
作者
Singh, Hari Narayan [1 ]
Agrawal, Sanat [1 ]
Kuthe, Abhaykumar M. [2 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Srinagar, Uttarakhand, India
[2] Visvesvaraya Natl Inst Technol, Dept Mech Engn, Nagpur, Maharashtra, India
关键词
Additive manufacturing; Cranial reconstruction; Finite element analysis; 3D printing; Customized cranial implant; CRANIOPLASTY; DEFECTS; HYDROXYAPATITE; BEHAVIOR; REPAIR; BONE;
D O I
10.1016/j.jmbbm.2023.106061
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A methodology has been developed in this work to design customized cranial implants from computed tomography (CT) scan images for symmetric as well as asymmetric defects. The two-dimensional CT scan images were converted into three-dimensional geometric models using software packages. Two cases of cranial cavities at different locations were considered for implant design using two different approaches. Case 1 is having a symmetric cranial cavity while Case 2 has an asymmetric frontal cranial cavity. The craniums with defects were 3D reconstructed. Customized cranial implants were made for the two cases. In Case 1, symmetry was used to design the cranial implant. Symmetry cannot be used in Case 2. In Case 2, the implant was designed by blending from the surface available adjacent to the missing portion of the cranium. 3D reconstructed bone models and customized implants were 3D printed in poly-lactic acid (PLA) using a fused deposition modeling process for form and fit evaluation. Finite element analysis was performed to compare the mechanical behavior of bone, and the two biomaterials - polyether ether ketone (PEEK), and Ti6Al4V. Static structural finite element analysis was performed to simulate the impact of falling off a bicycle with an impact on the cranial implants in the two cases. The load was modeled as a normal force acting on the surface of the implant. It was found that the stresses in the titanium alloy are comparable to those of PEEK for both the cases. However, the strains and deformation were found to be much smaller compared to those in PEEK. Therefore, the titanium alloy is the material of choice for both the cases among the materials under consideration. The designed implants are solid hence may face the challenge in bone ingrowth. In future studies, the implant can be made porous by incorporating a lattice structure to enhance osseointegration and promote bone ingrowth. Implants for both symmetric and asymmetric defect cases in cranium were successfully designed.
引用
收藏
页数:13
相关论文
共 43 条
  • [1] Polyetheretherketone custom-made implants for craniofacial defects: Report of 14 cases and review of the literature
    Alonso-Rodriguez, E.
    Cebrian, J. L.
    Nieto, M. J.
    Del Castillo, J. L.
    Hernandez-Godoy, J.
    Burgueno, M.
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (07) : 1232 - 1238
  • [2] Structure, properties, and bioactivity of 3D printed PAEKs for implant applications: A systematic review
    Basgul, Cemile
    Spece, Hannah
    Sharma, Neha
    Thieringer, Florian M.
    Kurtz, Steven M.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2021, 109 (11) : 1924 - 1941
  • [3] Bin Lu, 2015, Key Engineering Materials, V639, P535, DOI 10.4028/www.scientific.net/KEM.639.535
  • [4] Metal additive manufacturing in aerospace: A review
    Blakey-Milner, Byron
    Gradl, Paul
    Snedden, Glen
    Brooks, Michael
    Pitot, Jean
    Lopez, Elena
    Leary, Martin
    Berto, Filippo
    du Plessis, Anton
    [J]. MATERIALS & DESIGN, 2021, 209
  • [5] Modelling and structural analysis of skull/cranial implant: beyond mid-line deformities
    Bogu, V. Phanindra
    Kumar, Y. Ravi
    Khanara, Asit Kumar
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2017, 19 (01) : 125 - 131
  • [6] The Recent Revolution in the Design and Manufacture of Cranial Implants: Modern Advancements and Future Directions
    Bonda, David J.
    Manjila, Sunil
    Selman, Warren R.
    Dean, David
    [J]. NEUROSURGERY, 2015, 77 (05) : 814 - 824
  • [7] Mechanical characterization and numerical simulation of polyether-ether-ketone (PEEK) cranial implants
    El Halabi, F.
    Rodriguez, J. F.
    Rebolledo, L.
    Hurtos, E.
    Doblare, M.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (08) : 1819 - 1832
  • [8] Fahlstedt M., 2012, Proc. IRCOBI, P787
  • [9] Osteointegration in Custom-made Porous Hydroxyapatite Cranial Implants: From Reconstructive Surgery to Regenerative Medicine
    Fricia, Marco
    Passanisi, Maurizio
    Salamanna, Francesca
    Parrilli, Annapaola
    Giavaresi, Gianluca
    Fini, Milena
    [J]. WORLD NEUROSURGERY, 2015, 84 (02) : 591.e11 - 591.E16
  • [10] Gibson I, 2005, ADVANCED MANUFACTURING TECHNOLOGY FOR MEDICAL APPLICATIONS: REVERSE ENGINEERING, SOFTWARE CONVERSION AND RAPID PROTOTYPING, P1, DOI 10.1002/0470033983