A Biphasic Fluid-Structure Interaction Model of Backflow During Infusion Into Agarose Gel

被引:2
作者
Ayers, Arthur D. [1 ]
Smith, Joshua H. [1 ]
机构
[1] Lafayette Coll, Dept Mech Engn, Easton, PA 18042 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2023年 / 145卷 / 12期
关键词
CONVECTION-ENHANCED DELIVERY; MALIGNANT GLIOMAS; BRAIN; CANNULA; PLACEMENT; THERAPY; DESIGN;
D O I
10.1115/1.4063747
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The efficacy of convection-enhanced delivery as a technique to treat disorders of the central nervous system is limited by backflow, in which the infused fluid flows backward along surface of the catheter rather than toward the targeted area. In order to improve treatment protocols, finite element models of backflow have been developed to understand the underlying physics. Garcia et al. (2013, "Description and Validation of a Finite Element Model of Backflow During Infusion Into a Brain Tissue Phantom," ASME J. Comput. Nonlinear Dyn., 8(1), p. 011017) presented a finite element model that accounted for the flow in the annular gap that develops between the tissue and the outer surface of the catheter by using a layer of biphasic elements with a formula for the axial hydraulic conductivity to represent annular Poiseuille flow. In this study, we present a generalization of that model using fluid-FSI and biphasic-FSI elements that are recently available in febio. We demonstrate that our model of a 0.98 mm radius catheter is able to reproduce experimental backflow lengths and maximum fluid pressures for infusions into a brain tissue surrogate and that it agrees well with the previous model by Garcia et al. (2013, "Description and Validation of a Finite Element Model of Backflow During Infusion Into a Brain Tissue Phantom," ASME J. Comput. Nonlinear Dyn., 8(1), p. 011017). The model predicts that the backflow length and the total amount of flow into the hemispherical region forward of the catheter tip is comparable for two different catheter sizes, albeit at a higher fluid pressure for the smaller catheter. This biphasic-FSI model has the potential to be extended to a stepped catheter geometry, which has been shown in experiments to be successful in controlling backflow.
引用
收藏
页数:8
相关论文
共 44 条
[1]   Finite Element Framework for Computational Fluid Dynamics in FEBIO [J].
Ateshian, Gerard A. ;
Shim, Jay J. ;
Maas, Steve A. ;
Weiss, Jeffrey A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (02)
[2]   Convection-Enhanced Drug Delivery to the Brain: Therapeutic Potential and Neuropathological Considerations [J].
Barua, Neil U. ;
Gill, Steven S. ;
Love, Seth .
BRAIN PATHOLOGY, 2014, 24 (02) :117-127
[3]   Physical characterization of neurocatheter performance in a brain phantom gelatinwith nanoscale porosity: steady-state and oscillatory flows [J].
Bauman, MA ;
Gillies, GT ;
Raghavan, R ;
Brady, ML ;
Pedain, C .
NANOTECHNOLOGY, 2004, 15 (01) :92-97
[4]   CONVECTION-ENHANCED DELIVERY OF MACROMOLECULES IN THE BRAIN [J].
BOBO, RH ;
LASKE, DW ;
AKBASAK, A ;
MORRISON, PF ;
DEDRICK, RL ;
OLDFIELD, EH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (06) :2076-2080
[5]  
Bonet J, 2008, NONLINEAR CONTINUUM MECHANICS FOR FINITE ELEMENT ANALYSIS, 2ND EDITION, P1, DOI 10.1017/CBO9780511755446
[6]  
Brady M. L., 2019, Backflow Mitigation in Stepped Catheters, DOI [10.13140/RG.2.2.30212.27522, DOI 10.13140/RG.2.2.30212.27522]
[7]   In-vitro and in-vivo performance studies of a porous infusion catheter designed for intraparenchymal delivery of therapeutic agents of varying size [J].
Brady, Martin L. ;
Grondin, Richard ;
Zhang, Zhiming ;
Pomerleau, Francois ;
Powell, David ;
Huettl, Pete ;
Wilson, Mike ;
Stice, Jim ;
Gerhardt, Greg A. ;
Abramov, Vasiliy ;
Raghavan, Raghu .
JOURNAL OF NEUROSCIENCE METHODS, 2022, 378
[8]   A comprehensive outlook on intracerebral therapy of malignant gliomas [J].
Buonerba, Carlo ;
Di Lorenzo, Giuseppe ;
Marinelli, Alfredo ;
Federico, Piera ;
Palmieri, Giovannella ;
Imbimbo, Martina ;
Conti, Pio ;
Peluso, Gianfranco ;
De Placido, Sabino ;
Sampson, John H. .
CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2011, 80 (01) :54-68
[9]   Influence of Needle Insertion Speed on Backflow for Convection-Enhanced Delivery [J].
Casanova, Fernando ;
Carney, Paul R. ;
Sarntinoranont, Malisa .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (04)
[10]   Variables affecting convection-enhanced delivery to the striatum: a systematic examination of rate of infusion, cannula size, infusate concentration, and tissue-cannula sealing time [J].
Chen, MY ;
Lonser, RR ;
Morrison, PF ;
Governale, LS ;
Oldfield, EH .
JOURNAL OF NEUROSURGERY, 1999, 90 (02) :315-320