Long-term safety and efficacy of left atrial appendage closure in patients with small appendage orifices measured with transesophageal echocardiography

被引:1
作者
Wang, Binhao [1 ,2 ]
Wang, Zhao [3 ]
Chu, Huimin [1 ,2 ]
He, Bin [1 ,2 ]
Fu, Guohua [1 ,2 ]
Feng, Mingjun [1 ,2 ]
Du, Xianfeng [1 ,2 ]
Liu, Jing [1 ,2 ]
Yu, Yibo [1 ,2 ]
机构
[1] Ningbo First Hosp, Arrhythmia Ctr, Liuting Rd 59, Ningbo 315010, Zhejiang, Peoples R China
[2] Key Lab Precis Med Atherosclerot Dis Zhejiang Pro, Ningbo, Peoples R China
[3] Ningbo First Hosp, Dept Ultrasonog, Ningbo, Peoples R China
关键词
atrial fibrillation; left atrial appendage closure; stroke; Watchman; WATCHMAN DEVICE; EMBOLIC PROTECTION; FIBRILLATION; EXPERIENCE; WARFARIN; OUTCOMES; SYSTEM;
D O I
10.1002/clc.23950
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The Watchman device is the most widely used occluder but is indicated in atrial fibrillation (AF) patients with a maximal left atrial appendage (LAA) orifice diameter between 17 and 31 mm. We aimed to compare the long-term safety and efficacy of left atrial appendage closure (LAAC) between patients with a small LAA (<17 mm) and those with an indicated LAA (17-31 mm) measured by transesophageal echocardiography (TEE). Methods A total of 369 AF patients treated with LAAC between March 2015 and February 2019 were included and divided into two groups based on the maximal LAA orifice diameter measured by TEE: small LAA group (n = 22) and indicated LAA group (n = 347). Periprocedural complications and long-term clinical outcomes were compared. Results The Watchman device was successfully implanted in all patients. Mean device compression was higher in the small LAA group. Four patients (1.2%) in the indicated LAA group experienced pericardial effusion, and none experienced pericardial effusion in the small LAA group. Device-related thrombus was detected in one (4.5%) patient in the small LAA group and five (1.4%) in the indicated LAA group (p = .310). After a mean follow-up period of 4.1 +/- 1.6 years, one patient in the small LAA group (4.5%; 1.1/100 person-years) and four in the indicated LAA group (1.2%; 0.3/100 person-years) suffered an ischemic stroke (p = .266). Conclusions The safety and efficacy of LAAC with the Watchman device were comparable between patients with small and indicated LAA orifice diameters measured by TEE.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 29 条
[1]   Left atrial appendage: structure, function, and role in thromboembolism [J].
Al-Saady, NM ;
Obel, OA ;
Camm, AJ .
HEART, 1999, 82 (05) :547-554
[2]  
Blomstrom-Lundqvist C., 2021, EUR HEART J, V42, P373
[3]   Evaluating Real-World Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology Final 2-Year Outcome Data of the EWOLUTION Trial Focusing on History of Stroke and Hemorrhage [J].
Boersma, Lucas V. ;
Ince, Hueseyin ;
Kische, Stephan ;
Pokushalov, Evgeny ;
Schmitz, Thomas ;
Schmidt, Boris ;
Gori, Tommaso ;
Meincke, Felix ;
Protopopov, Alexey Vladimir ;
Betts, Timothy ;
Mazzone, Patrizio ;
Foley, David ;
Grygier, Marek ;
Sievert, Horst ;
De Potter, Tom ;
Vireca, Elisa ;
Stein, Kenneth ;
Bergmann, Martin W. ;
Al Nooryani, Arif ;
Meincke, Felix ;
Fiedler, Thomas ;
Senatore, Gaetano ;
Foley, David ;
Schmidt, Boris ;
Brigadeau, Francois ;
Defaye, Pascal ;
Teiger, Emmanuel ;
Bonnet, Jean-Louis ;
Wald, Christof ;
Schmitz, Thomas ;
Szili-Torok, Tamas ;
Tschishow, Wladimir ;
Mazzone, Patrizio ;
Crossland, David ;
Bergmann, Martin W. ;
Vahanian, Alec ;
Cruz-Gonzalez, Ignacio ;
Thambo, Jean-Benoit ;
Gori, Tommaso ;
Betts, Timothy ;
Al Smadi, Faisal ;
Mudra, Harald ;
Molitoris, Robin ;
Folkeringa, Richard ;
Stevenhagen, Yorick ;
Gras, Daniel ;
De Potter, Tom ;
Tamburino, Corrado ;
Molon, Giulio ;
Protopopov, Vladimir .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (04)
[4]   Left atrial appendage closure in patients with prohibitive anatomy: Insights from PINNACLE FLX [J].
Ellis, Christopher R. ;
Jackson, Gregory G. ;
Kanagasundram, Arvindh N. ;
Mansour, Moussa ;
Sutton, Brad ;
Houle, Vicki M. ;
Kar, Saibal ;
Doshi, Shephal ;
Osorio, Jose .
HEART RHYTHM, 2021, 18 (07) :1153-1161
[5]   MORPHOLOGY OF THE LEFT ATRIAL APPENDAGE [J].
ERNST, G ;
STOLLBERGER, C ;
ABZIEHER, F ;
VEITDIRSCHERL, W ;
BONNER, E ;
BIBUS, B ;
SCHNEIDER, B ;
SLANY, J .
ANATOMICAL RECORD, 1995, 242 (04) :553-561
[6]   Safety and effects of volume loading during transesophageal echocardiography in the pre-procedural work-up for left atrial appendage closure [J].
Freitas-Ferraz, Afonso B. ;
Bernier, Mathieu ;
O'Connor, Kim ;
Beaudoin, Jonathan ;
Champagne, Jean ;
Paradis, Jean-Michel ;
O'Hara, Gilles ;
Muntane-Carol, Guillem ;
Alperi, Alberto ;
Faroux, Laurent ;
Junquera, Lucia ;
Rodes-Cabau, Josep .
CARDIOVASCULAR ULTRASOUND, 2021, 19 (01)
[7]   Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin Therapy [J].
Holmes, David R., Jr. ;
Kar, Saibal ;
Price, Matthew J. ;
Whisenant, Brian ;
Sievert, Horst ;
Doshi, Shephal K. ;
Huber, Kenneth ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (01) :1-12
[8]   Primary Outcome Evaluation of a Next-Generation Left Atrial Appendage Closure Device Results From the PINNACLE FLX Trial [J].
Kar, Saibal ;
Doshi, Shephal K. ;
Sadhu, Ashish ;
Horton, Rodney ;
Osorio, Jose ;
Ellis, Christopher ;
Stone, James, Jr. ;
Shah, Manish ;
Dukkipati, Srinivas R. ;
Adler, Stuart ;
Nair, Devi G. ;
Kim, Jamie ;
Wazni, Oussama ;
Price, Mathew J. ;
Asch, Federico M. ;
Holmes, David R., Jr. ;
Shipley, Robert D. ;
Gordon, Nicole T. ;
Allocco, Dominic J. ;
Reddy, Vivek Y. .
CIRCULATION, 2021, 143 (18) :1754-1762
[9]   Peridevice Leak Following Amplatzer Left Atrial Appendage Occlusion Cardiac Computed Tomography Classification and Clinical Outcomes [J].
Korsholm, Kasper ;
Jensen, Jesper Moller ;
Norgaard, Bjarne Linde ;
Samaras, Athanasios ;
Saw, Jacqueline ;
Berti, Sergio ;
Tzikas, Apostolos ;
Nielsen-Kudsk, Jens Erik .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (01) :83-93
[10]   The Watchman FLX Device First European Experience and Feasibility of Intracardiac Echocardiography to Guide Implantation [J].
Korsholm, Kasper ;
Samaras, Athanasios ;
Andersen, Asger ;
Jensen, Jesper Moller ;
Nielsen-Kudsk, Jens Erik .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (13) :1633-1642