On timing-optimized SiPMs for Cherenkov detection to boost low cost time-of-flight PET

被引:21
作者
Gundacker, Stefan [1 ]
Borghi, Giacomo [2 ]
Cherry, Simon R. [3 ]
Gola, Alberto [2 ]
Lee, Daehee [3 ]
Merzi, Stefano [2 ]
Penna, Michele [2 ,4 ]
Schulz, Volkmar [1 ]
Kwon, Sun Il [3 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, Forckenbeckstr 55, D-52074 Aachen, Germany
[2] Fdn Bruno Kessler, Via Sommar 18, I-38123 Trento, Italy
[3] Univ Calif Davis, Dept Biomed Engn, One Shields Ave, Davis, CA 95616 USA
[4] Politecn Torino, Dipartimento Elettron & Telecomunicazioni, Corso Duca Abruzzi 24, I-10129 Turin, Italy
基金
美国国家卫生研究院;
关键词
fast timing; BGO; FBK NUV-HD; Cherenkov; TOF-PET; single photon time resolution (SPTR); coincidence time resolution (CTR); ANALOG;
D O I
10.1088/1361-6560/ace8ee
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Recent SiPM developments and improved front-end electronics have opened new doors in TOF-PET with a focus on prompt photon detection. For instance, the relatively high Cherenkov yield of bismuth-germanate (BGO) upon 511 keV gamma interaction has triggered a lot of interest, especially for its use in total body positron emission tomography (PET) scanners due to the crystal's relatively low material and production costs. However, the electronic readout and timing optimization of the SiPMs still poses many questions. Lab experiments have shown the prospect of Cherenkov detection, with coincidence time resolutions (CTRs) of 200 ps FWHM achieved with small pixels, but lack system integration due to an unacceptable high power uptake of the used amplifiers. Approach. Following recent studies the most practical circuits with lower power uptake (<30 mW) have been implemented and the CTR performance with BGO of newly developed SiPMs from Fondazione Bruno Kessler tested. These novel SiPMs are optimized for highest single photon time resolution (SPTR). Main results. We achieved a best CTR FWHM of 123 ps for 2 x 2 x 3 mm(3) and 243 ps for 3 x 3 x 20 mm(3) BGO crystals. We further show that with these devices a CTR of 106 ps is possible using commercially available 3 x 3 x 20 mm(3) LYSO:Ce,Mg crystals. To give an insight in the timing properties of these SiPMs, we measured the SPTR with black coated PbF2 of 2 x 2 x 3 mm(3) size. We confirmed an SPTR of 68 ps FWHM published in literature for standard devices and show that the optimized SiPMs can improve this value to 42 ps. Pushing the SiPM bias and using 1 x 1 mm(2) area devices we measured an SPTR of 28 ps FWHM. Significance. We have shown that advancements in readout electronics and SiPMs can lead to improved CTR with Cherenkov emitting crystals. Enabling time-of-flight with BGO will trigger a high interest for its use in low-cost and total-body PET scanners. Furthermore, owing to the prompt nature of Cherenkov emission, future CTR improvements are conceivable, for which a low-power electronic implementation is indispensable. In an extended discussion we will give a roadmap to best timing with prompt photons.
引用
收藏
页数:13
相关论文
共 23 条
  • [1] Understanding and simulating SiPMs
    Acerbi, Fabio
    Gundacker, Stefan
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 926 : 16 - 35
  • [2] First Human Imaging Studies with the EXPLORER Total-Body PET Scanner
    Badawi, Ramsey D.
    Shi, Hongcheng
    Hu, Pengcheng
    Chen, Shuguang
    Xu, Tianyi
    Price, Patricia M.
    Ding, Yu
    Spencer, Benjamin A.
    Nardo, Lorenzo
    Liu, Weiping
    Bao, Jun
    Jones, Terry
    Li, Hongdi
    Cherry, Simon R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (03) : 299 - 303
  • [3] BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET
    Brunner, S. E.
    Schaart, D. R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) : 4421 - 4439
  • [4] Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET
    Cates, Joshua W.
    Choong, Woon-Seng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (19)
  • [5] Electronics method to advance the coincidence time resolution with bismuth germanate
    Cates, Joshua W.
    Levin, Craig S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17)
  • [6] Improved single photon time resolution for analog SiPMs with front end readout that reduces influence of electronic noise
    Cates, Joshua W.
    Gundacker, Stefan
    Auffray, Etiennette
    Lecoq, Paul
    Levin, Craig S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (18)
  • [7] The new opportunities for high time resolution clinical TOF PET
    Conti, Maurizio
    Bendriem, Bernard
    [J]. CLINICAL AND TRANSLATIONAL IMAGING, 2019, 7 (02) : 139 - 147
  • [8] Analog Circuit for Timing Measurements With Large Area SiPMs Coupled to LYSO Crystals
    Gola, Alberto
    Piemonte, Claudio
    Tarolli, Alessandro
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 1296 - 1302
  • [9] On the comparison of analog and digital SiPM readout in terms of expected timing performance
    Gundacker, S.
    Auffray, E.
    Jarron, P.
    Meyer, T.
    Lecoq, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 6 - 11
  • [10] Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: an experimental and theoretical analysis
    Gundacker, S.
    Auffray, E.
    Frisch, B.
    Jarron, P.
    Knapitsch, A.
    Meyer, T.
    Pizzichemi, M.
    Lecoq, P.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8