Endobronchial Ultrasound Elastography for Diagnosing Mediastinal and Hilar Lymph Nodes

被引:0
作者
He HaiYan [1 ,2 ,3 ,4 ,5 ]
Huang Mao [1 ,6 ,7 ,8 ,5 ]
Zhu Jie [1 ,2 ,3 ,4 ,5 ]
Ma Hang [1 ,6 ,7 ,8 ,5 ]
Lyu XueDong
机构
[1] Department of Respiratory
[2] The First People’s Hospital of Nantong
[3] Nantong
[4] Jiangsu
[5] China
[6] The First Affiliated Hospital of Nanjing Medical University
[7] Nanjing
关键词
Elastography; Endobronchial Ultrasound; Lung Cancer; Mediastinal and Hilar Lymph Node; Strain Ratio;
D O I
暂无
中图分类号
R734.2 [肺肿瘤]; R445.1 [超声波诊断];
学科分类号
100214 ; 100207 ;
摘要
Background: Pathophysiological processes, such as malignancy, can lead to the formation of stiffer tissue in lung cancers. Endobronchial ultrasound (EBUS) elastography is a novel technique for measuring tissue stiffness during EBUS-guided transbronchial needle aspiration (EBUS-TBNA). The current study was conducted to investigate the diagnostic value of EBUS elastography for mediastinal and hilar lymph node metastasis in lung cancers.Methods: From January 2014 to January 2015, 40 patients suspected of lung cancer were enrolled, and a total of 68 lymph nodes were evaluated by EBUS-TBNA. EBUS-guided elastography of lymph nodes was performed prior to EBUS-TBNA. Standard EBUS characteristics were also described. Pathological determination of malignant or benign lymph nodes was used as the gold standard for this study. If EBUS-TBNA did not result in a formal pathological diagnosis of malignancy, patients were referred for a surgical procedure. Comparisons of elastography and standard EBUS characteristics were made between benign and malignant lymph nodes.Results: Elastography grading scores and strain ratios showed significant differences between benign and malignant lymph nodes (P = 0.000). The elastography strain ratio was more sensitive and specific for determining malignant lymph nodes than elastography grading score or standard EBUS criteria. The receiver operating characteristic curve for the elastography strain ratio showed an area under the curve of 0.933. The best cut-off point of the strain ratio for differentiating malignant from benign lymph nodes was 32.07. The elastography strain ratio had a sensitivity of 88.1%, the specificity of 80.8%, positive predictive value of 88.1%, and negative predictive value of 80.8% for distinguishing malignant from benign nodes. The overall accuracy of elastography strain ratio was 85.3%. The strain ratio of malignant and benign lymph nodes positively correlated with the elastography grading score (r = 0.561,P= 0.000).Conclusions: EBUS elastography can be effectively used to predict mediastinal and hilar lymph node metastases in lung cancer. This noninvasive technique may thus complement standard EBUS and help guide EBUS-TBNA procedures.
引用
收藏
页码:2720 / 2725
页数:6
相关论文
共 50 条
[41]   Endobronchial ultrasound images may predict malignant involvement of mediastinal lymph nodes: Is tissue still the issue? [J].
Casal, Roberto F. .
RESPIROLOGY, 2012, 17 (08) :1155-1156
[42]   The sonographic features of malignant mediastinal lymph nodes and a proposal for an algorithmic approach for sampling during endobronchial ultrasound [J].
Alici, Ibrahim Onur ;
Demirci, Nilgun Yilmaz ;
Yilmaz, Aydin ;
Karakaya, Jale ;
Ozaydin, Esra .
CLINICAL RESPIRATORY JOURNAL, 2016, 10 (05) :606-613
[43]   An Assessment of the Adequacy of Endobronchial Ultrasound to Assess Mediastinal Lymph Nodes Accompanying Extrathoracic Malignancies [J].
Dirol, Hulya ;
Uzun, Rusen ;
Keskin, Olgun .
ERCIYES MEDICAL JOURNAL, 2022, 44 (03) :252-256
[44]   Ultrasound Elastography for the Evaluation of Lymph Nodes [J].
Wang, Bin ;
Guo, Qi ;
Wang, Jia-Yu ;
Yu, Yang ;
Yi, Ai-Jiao ;
Cui, Xin-Wu ;
Dietrich, Christoph F. .
FRONTIERS IN ONCOLOGY, 2021, 11
[45]   Automatic Segmentation of Mediastinal Lymph Nodes and Blood Vessels in Endobronchial Ultrasound (EBUS) Images Using Deep Learning [J].
Ervik, Oyvind ;
Tveten, Ingrid ;
Hofstad, Erlend Fagertun ;
Lango, Thomas ;
Leira, Hakon Olav ;
Amundsen, Tore ;
Sorger, Hanne .
JOURNAL OF IMAGING, 2024, 10 (08)
[46]   Comparison of 21-gauge and 22-gauge Needles for Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration of Mediastinal and Hilar Lymph Nodes [J].
Saji, Junko ;
Kurimoto, Noriaki ;
Morita, Katsuhiko ;
Nakamura, Miho ;
Inoue, Takeo ;
Nakamura, Haruhiko ;
Miyazawa, Teruomi .
JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2011, 18 (03) :239-246
[47]   Endobronchial ultrasonography for mediastinal and hilar lymph node metastases of lung cancer [J].
Okamoto, H ;
Watanabe, K ;
Nagatomo, A ;
Kunikane, H ;
Aono, H ;
Yamagata, T ;
Kase, M .
CHEST, 2002, 121 (05) :1498-1506
[48]   Gene expression profiling of endobronchial ultrasound (EBUS)-derived cytological fine needle aspirates from hilar and mediastinal lymph nodes in non-small cell lung cancer [J].
Lee, R. ;
Cousins, D. J. ;
Ortiz-Zapater, E. ;
Breen, R. ;
McLean, E. ;
Santis, G. .
CYTOPATHOLOGY, 2013, 24 (06) :351-355
[49]   SONOGRAPHIC FEATURES OF ENDOBRONCHIAL ULTRASOUND IN DIFFERENTIATION OF BENIGN LYMPH NODES [J].
Wang, Lei ;
Wu, Weihua ;
Teng, Jiajun ;
Zhong, Runbo ;
Han, Baohui ;
Sun, Jiayuan .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (12) :2785-2793
[50]   Endobronchial Ultrasound-Transbronchial Needle Aspiration of Mediastinal and Hilar Lymphadenopathy Learning Curve [J].
Kheir, Fayez ;
Alokla, Khalid ;
Myers, Leann ;
Palomino, Jaime .
AMERICAN JOURNAL OF THERAPEUTICS, 2016, 23 (04) :E1016-E1019