Increased osteopontin and liver stiffness measurement by transient elastography in biliary atresia

被引:0
|
作者
Sittisak Honsawek [1 ]
Maneerat Chayanupatkul [2 ]
Voranush Chongsrisawat [3 ]
Paisarn Vejchapipat [4 ]
Yong Poovorawan [3 ]
机构
[1] Department of Biochemistry, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital
[2] Department of Physiology, Faculty of Medicine, Chulalongkorn University
[3] Center of Excellence in Clinical Virology, Department of Pediatrics, Faculty of Medicine, Chulalongkorn University
[4] Department of Surgery, Faculty of Medicine, Chulalongkorn University
关键词
Biliary atresia; Fibroscan; Jaundice; Liver stiffness; Osteopontin;
D O I
暂无
中图分类号
R657.4 [胆囊、胆管];
学科分类号
1002 ; 100210 ;
摘要
AIM: To analyze plasma osteopontin levels and liver stiffness using transient elastography in postoperative biliary atresia (BA) children compared with healthy controls. METHODS: Thirty children with postoperative BA and 10 normal controls were enrolled. The patients were categorized into two groups according to their jaundicestatus. Plasma levels of osteopontin were determined using commercially available enzyme-linked immunosorbent assay. Liver stiffness was measured by using transient elastography (Fibroscan). Ten validated Fibroscan measurements were performed in each patient and control with the result expressed in kilopascals (kPa). RESULTS: Plasma osteopontin was significantly elevated in BA children compared with that of healthy controls (47.0 ± 56.4 ng/mL vs 15.1 ± 15.0 ng/mL, P = 0.01). The liver stiffness measurement was markedly elevated in the patients with BA compared with that of controls (26.9 ± 24.6 kPa vs 3.9 ± 0.7 kPa, P = 0.001). Subgroup analysis showed that the BA patients with jaundice had more pronounced plasma osteopontin levels than those without jaundice (87.1 ± 61.6 ng/mL vs 11.9 ± 6.1 ng/mL, P = 0.001). Furthermore, the mean liver stiffness was significantly greater in the jaundiced BA patients compared with non-jaundiced patients (47.7 ± 21.8 kPa vs 8.7 ± 3.0 kPa, P = 0.001). Additionally, plasma osteopontin was positively related to serum total bilirubin (r = 0.64, P < 0.001). There was also a correlation between plasma osteopontin and liver stiffness values (r = 0.60, P < 0.001). CONCLUSION: High plasma osteopontin positively correlated with degree of hepatic fibrosis and could be used as a biochemical parameter reflecting disease severity in postoperative BA children.
引用
收藏
页码:5467 / 5473
页数:7
相关论文
共 50 条
  • [1] Increased osteopontin and liver stiffness measurement by transient elastography in biliary atresia
    Honsawek, Sittisak
    Chayanupatkul, Maneerat
    Chongsrisawat, Voranush
    Vejchapipat, Paisarn
    Poovorawan, Yong
    WORLD JOURNAL OF GASTROENTEROLOGY, 2010, 16 (43) : 5467 - 5473
  • [2] Prospective Analysis of Liver Stiffness Measurement by Vibration Controlled Transient Elastography as a Predictor of Outcomes in Biliary Atresia
    Molleston, Jean p.
    Goodrich, Nathan p.
    Ye, Wen
    Leung, Daniel h.
    Sokol, Ronald j.
    Shneider, Benjamin l.
    GASTROENTEROLOGY, 2025, 168 (02)
  • [3] Connective tissue growth factor, liver stiffness and transient elastography in biliary atresia
    Wiwanitkit, Somsri
    Wiwanitkit, Viroj
    HEPATOLOGY RESEARCH, 2013, 43 (08) : 917 - 917
  • [4] Elevation of Serum Galectin-3 and Liver Stiffness Measured by Transient Elastography in Biliary Atresia
    Honsawek, S.
    Chongsrisawat, V.
    Praianantathavorn, K.
    Theamboonlers, A.
    Poovorawan, Y.
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2011, 21 (04) : 250 - 254
  • [5] Correlation of connective tissue growth factor with liver stiffness measured by transient elastography in biliary atresia
    Honsawek, Sittisak
    Udomsinprasert, Wanvisa
    Chirathaworn, Chintana
    Anomasiri, Wilai
    Vejchapipat, Paisarn
    Poovorawan, Yong
    HEPATOLOGY RESEARCH, 2013, 43 (07) : 795 - 800
  • [6] Comparison of the liver stiffness measurement by transient elastography with the liver biopsy
    Ioan Sporea
    Roxana ■irli
    Alexandra Deleanu
    Adriana Tudora
    Manuela Curescu
    Marioara Cornianu
    Daniela Lazǎr
    World Journal of Gastroenterology, 2008, (42) : 6513 - 6517
  • [7] Comparison of the liver stiffness measurement by transient elastography with the liver biopsy
    Sporea, Ioan
    Sirli, Roxana
    Deleanu, Alexandra
    Tudora, Adriana
    Curescu, Manuela
    Cornianu, Marioara
    Lazar, Daniela
    WORLD JOURNAL OF GASTROENTEROLOGY, 2008, 14 (42) : 6513 - 6517
  • [8] Transient Elastography and Sonography for Prediction of Liver Fibrosis in Infants With Biliary Atresia
    Shin, Na-Young
    Kim, Myung-Joon
    Lee, Mi-Jung
    Han, Seok Joo
    Koh, Hong
    Namgung, Ran
    Park, Young Nyun
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (05) : 853 - 864
  • [9] Liver Stiffness Measurement by Transient Elastography in Clinical Practice
    Sporea, Ioan
    Sirli, Roxana
    Deleanu, Alexandra
    Popescu, Alina
    Cornianu, Marioara
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2008, 17 (04) : 395 - 399
  • [10] Increased liver stiffness measurement by transient elastography in severe acute exacerbation of chronic hepatitis B
    Wong, Grace L-H
    Wong, Vincent W-S
    Choi, Paul C-L
    Chan, Anthony W-H
    Chim, Angel M-L
    Yiu, Karen K-L
    Chan, Francis K-L
    Sung, Joseph J-Y
    Chan, Henry L-Y
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 (06) : 1002 - 1007