医用钛合金表面纳米晶TiN梯度涂层的显微组织及腐蚀磨损性能(英文)

被引:8
作者
崔文芳 [1 ]
牛凤娟 [2 ]
谭韵玲 [1 ]
秦高梧 [1 ]
机构
[1] 东北大学材料科学与工程学院材料各向异性与织构教育部重点实验室
[2] 歌尔声学股份有限公司质检部
关键词
TiN涂层; 纳米晶; 硬度; 结合性; 腐蚀磨损性能;
D O I
暂无
中图分类号
TG178 [各种金属及合金的腐蚀、防腐与表面处理];
学科分类号
摘要
采用磁控溅射方法在Ti6Al4V钛合金表面制备纳米晶TiN梯度涂层,研究涂层的显微组织和力学性能,并对涂层和Ti6Al4V合金基体在生理环境中的电化学腐蚀行为和腐蚀磨损性能进行比较。结果表明:纳米晶TiN的梯度分布有利于释放涂层中的内应力,使粘附强度增加到90 N。致密的结构和细化的晶粒使涂层表面纳米硬度达到28.5 GPa,纳米晶TiN涂层的防腐蚀效率达到96.6%。与Ti6Al4V合金基体相比,纳米晶TiN涂层的耐腐蚀磨损性能提高了100倍。纳米晶TiN梯度涂层具有良好的化学稳定性和较高的H3/E2比(H为硬度,E为弹性模量),是改善耐腐蚀性能和抗磨损性能的主要原因。
引用
收藏
页码:1026 / 1035
页数:10
相关论文
共 28 条
  • [1] 磁控溅射沉积Ti/TiN多层膜的组织特征及耐磨损性能
    崔文芳
    曹栋
    秦高悟
    [J]. 金属学报, 2015, 51 (12) : 1531 - 1537
  • [2] Mechanical, wear and corrosion behavior of CrN/TiN multilayer coatings deposited by low temperature unbalanced magnetron sputtering for biomedical applications[J] . Stanislava Rabadzhiyska,Lilyana Kolaklieva,Vasiliy Chitanov,Tetiana Cholakova,Roumen Kakanakov,Nina Dimcheva,Konstantin Balashev.Materials Today: Proceedings . 2018 (8)
  • [3] Mechanical properties of TiN ceramic coating on a heat treated Ti-13Zr-13Nb alloy[J] . Jianzhong Li,Yifei Zhang,Yue Zhao.Journal of Alloys and Compounds . 2017
  • [4] A graded nano-TiN coating on biomedical Ti alloy: Low friction coefficient, good bonding and biocompatibility[J] . Wenfang Cui,Gaowu Qin,Jingzhu Duan,Huan Wang.Materials Science & Engineering C . 2017
  • [5] Duplex coatings with enhanced adhesion to Ti alloy substrate prepared by powder immersion nitriding and TiN/Ti multilayer deposition[J] . J.C. Avelar-Batista Wilson,Shoujun Wu,I. Gotman,J. Housden,E.Y. Gutmanas.Materials Letters . 2015
  • [6] Mechanical and tribological properties of CrN/TiN multilayer coatings deposited by pulsed dc magnetron sputtering[J] . Y.X. Ou,J. Lin,H.L. Che,W.D. Sproul,J.J. Moore,M.K. Lei.Surface & Coatings Technology . 2015
  • [7] The friction coefficient evolution of a TiN coated contact during sliding wear[J] . Guojia Ma,Liliang Wang,Haoxiang Gao,Jie Zhang,Tom Reddyhoff.Applied Surface Science . 2015
  • [8] Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells
    Posada, Olga M.
    Tate, Rothwelle J.
    Grant, M. Helen
    [J]. TOXICOLOGY IN VITRO, 2015, 29 (02) : 271 - 280
  • [9] Retrieval analysis of titanium nitride (TiN) coated prosthetic femoral heads articulating with polyethylene[J] . ?ukasz,?apaj,Justyna Wendland,Jacek Markuszewski,Adrian Mróz,Tomasz Wi?niewski.Journal of the Mechanical Behavior of Biomedical . 2015
  • [10] Interactions between mammalian cells and nano- or micro-sized wear particles: Physico-chemical views against biological approaches[J] . Polina Prokopovich.Advances in Colloid and Interface Science . 2014