Design and Performance Simulation of a Novel Liquid CO2 Cycle Refrigeration System for Heat Hazard Control in Coal Mines

被引:0
|
作者
ZHAI Xiaowei [1 ,2 ]
XU Yu [1 ,2 ]
YU Zhijin [1 ,2 ]
机构
[1] College of Safety Science and Engineering, Xi'an University of Science and Technology
[2] Shaanxi Key Laboratory of Prevention and Control of Coal Fire
基金
中国国家自然科学基金;
关键词
LCO2; refrigeration; working face cooling; numerical simulation; heat exchange;
D O I
暂无
中图分类号
TD727.2 [];
学科分类号
081903 ;
摘要
LCO2(liquid CO2) can absorb heat and release latent heat via phase transition, which can provide considerable cooling energy and effectively solve the problem of thermal damage in deep coal mining processes. A LCO2cycle refrigeration system is designed to continuously cool down the working face in a mine, and CO2is cyclically utilized. Additionally, LCO2is used not only as a cold source but also to prevent spontaneous combustion of coal in the gob. COMSOL Multiphysics simulation software is used to characterize the thermal performance of the heat exchange system, where the heat transfers between the CO2and the airflow. For a LCO2consumption of 13.54 m~3/h, the temperature of the airflow in the tunnel decreases by 7.72°C, and the cooling volume of the system reaches 142.99 kW/h; the cooling volume provides a latent heat release of 46.68 k W/h. The main influencing factors of the refrigeration system, such as ventilation flux, LCO2flow, LCO2temperature and initial tunnel temperature, are also analyzed quantitatively through the software. The temperature of the steady airflow in the tunnel is proportional to the square of the local fan ventilation flux, and it decreases linearly with an increase in the LCO2flow but increases with both the temperature of the LCO2and the initial temperature in the tunnel. When the temperature difference between the LCO2and wind increases, the heat exchange between the CO2and wind intensifies, and the cooling volume increases.
引用
收藏
页码:585 / 595
页数:11
相关论文
共 50 条
  • [31] Influence of ambient temperatures on performance of a CO2 heat pump water heating system
    Yokoyama, Ryohei
    Shimizu, Takeshi
    Ito, Koichi
    Takemura, Kazuhisa
    ENERGY, 2007, 32 (04) : 388 - 398
  • [32] Cooling performance of a variable speed CO2 cycle with an electronic expansion valve and internal heat exchanger
    Cho, Honghyun
    Ryu, Changgi
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04): : 664 - 671
  • [33] Theoretical investigation of a novel distributed compression cycle for CO2 trans-critical system
    Wang, Lei
    Zhang, Yumei
    Ma, Guoyuan
    ENERGY AND BUILDINGS, 2024, 304
  • [34] A Numerical Simulation on Heat Transfer Behaviors in the Gas Cooler of a CO2 Air Conditioning System
    Thanhtrung Dang
    Kiencuong Giang
    Hoangtuan Nguyen
    Baphuoc Le
    PROCEEDINGS OF 2019 INTERNATIONAL CONFERENCE ON SYSTEM SCIENCE AND ENGINEERING (ICSSE), 2019, : 653 - 657
  • [35] Effect of spindle position on the performance and two-phase characteristics of controllable ejector for transcritical CO2 refrigeration system
    Chandran, R. Jishnu
    Arumugam, Senthil Kumar
    Sadasivan, Sreeja
    John, Bibin
    Kanna, P. Rajesh
    JOURNAL OF SUPERCRITICAL FLUIDS, 2024, 205
  • [36] Hybrid solar-assisted trans-critical CO2 refrigeration cycle optimization with internal heat exchange for hot climate applications
    Tarawneh, Mohammad
    Melhem, Emad Bani
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 60
  • [37] EXERGETIC ANALYSIS OF CO2 TRANS-CRITICAL REFRIGERATION SYSTEM WITH AND WITHOUT INTERNAL HEAT EXCHANGER USING EXPERIMENTAL DATA
    Purohit, Nilesh
    Gupta, Dileep Kumar
    Dasgupta, Mani Sankar
    5TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2018, : 566 - 574
  • [38] Performance analysis of two-stage compression transcritical CO2 refrigeration system with 8290 mechanical subcooling unit
    Liu, Shengchun
    Lu, Fenping
    Dai, Baomin
    Nian, Victor
    Li, Hailong
    Qi, Haifeng
    Li, Jiayu
    ENERGY, 2019, 189
  • [39] Numerical study of the thermohydraulic performance of printed circuit heat exchangers for supercritical CO2 Brayton cycle applications
    Chai, Lei
    Tassou, Savvas A.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS INCLUDING WORKSHOP ON ENERGY RECOVERY CONVERSION AND MANAGEMENT;ICSEF 2018, 2019, 161 : 480 - 488
  • [40] Performance analysis of a hot water supply system with a CO2 heat pump by numerical simulation (1st report, modeling and analysis of heat pump)
    Yokoyama, Ryohei
    Shimuzu, Takeshi
    Takemura, Kazuhisa
    Ito, Koichi
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2005, 71 (707): : 1885 - 1892