Experimental study on spray cooling under reduced pressures

被引:0
作者
PENG Can [1 ]
XU XiangHua [1 ]
LI Ye Ming [1 ]
LI YuLong [2 ]
LIANG XinGang [1 ]
机构
[1] Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, School of Aerospace Engineering, Tsinghua University
[2] School of Energy and Power Engineering, Beihang University
关键词
spray cooling; flash evaporation; reduced pressure; phase change;
D O I
暂无
中图分类号
TB65 [制冷机械和设备];
学科分类号
0807 ; 080705 ;
摘要
Spay cooling is a complicated flow and heat transfer process affected by multi-factors among which the environmental pressure is extremely important. However the influence of pressure is not investigated sufficiently, especially the reduced pressure. In the present study, spray cooling under low initial environmental partial pressures and vapor partial pressures with R21 are investigated with a closed spray and condensation system. To study the influence of initial environmental partial pressure, different amounts of nitrogen are inflated into the vacuum flash chamber, while the vapor partial pressure is kept constant. To study the influence of vapor partial pressure, a cascade refrigerator is used to condense the vapor with different condensation temperatures so that the vapor partial pressure can be maintained or adjusted, while the initial environmental partial pressure is kept constant.The experimental results show that the spray cooling power increases monotonically with the increasing spray flow rate in the experimental range, while the cooling efficiency decreases with the increasing spray flow rate. The spray cooling power and cooling efficiency vary with the initial environmental partial pressure or the vapor partial pressure non-monotonously, which indicates there is an optimal pressure for the heat transfer performance. Besides, the mechanism of the non-monotonous variation trend is discussed based on the key aspects including flash evaporation, convection and boiling. Especially, the boiling heat transfer curve is applied to explain the trend.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 14 条
[1]   毛细矩形微槽群表面喷雾冷却实验研究 [J].
谢宁宁 ;
胡学功 ;
唐大伟 .
工程热物理学报, 2010, 31 (05) :805-809
[2]  
Coupling effect of hypobaric pressure and spray distance on heat transfer dynamics of R134a pulsed flashing spray cooling[J] . Zhi-fu Zhou,Bin Chen,Rui Wang,Fei-long Bai,Guo-xiang Wang.Experimental Thermal and Fluid Science . 2016
[3]  
Experimental investigation of spray cooling on smooth and micro-structured surfaces[J] . Zhen Zhang,Pei-Xue Jiang,Xiao-Long Ouyang,Jian-Nan Chen,David M. Christopher.International Journal of Heat and Mass Transfer . 2014
[4]   Experimental study on the effects of spray inclination on water spray cooling performance in non-boiling regime [J].
Wang, Yaqing ;
Liu, Minghou ;
Liu, Dong ;
Xu, Kan ;
Chen, Yiliang .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (07) :933-942
[5]  
Spray cooling heat transfer: The state of the art[J] . Jungho Kim.International Journal of Heat and Fluid Flow . 2006 (4)
[6]  
Spray cooling of enhanced surfaces: Impact of structured surface geometry and spray axis inclination[J] . Eric A. Silk,Jungho Kim,Ken Kiger.International Journal of Heat and Mass Transfer . 2006 (25)
[7]  
Single-phase and two-phase cooling characteristics of upward-facing and downward-facing sprays[J] . Jon R. Rybicki,Issam Mudawar.International Journal of Heat and Mass Transfer . 2005 (1)
[8]   Spray cooling in a closed system with different fractions of non-condensibles in the environment [J].
Jiang, SJ ;
Dhir, VK .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (25) :5391-5406
[9]   Optimal spray characteristics in water spray cooling [J].
Chen, RH ;
Chow, LC ;
Navedo, JE .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (23) :5095-5099
[10]   Heat transfer characteristics of spray cooling in a closed loop [J].
Lin, LC ;
Ponnappan, R .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (20) :3737-3746