Ultrasound-triggered Microbubble Destruction in Combination with Cationic Lipid Microbubbles Enhances Gene Delivery

被引:0
|
作者
张丽 [1 ]
刘莹莹 [1 ]
项光亚 [2 ]
吕清 [1 ]
黄桂 [1 ]
杨亚莉 [1 ]
张艳容 [1 ]
宋越 [1 ]
周欢 [2 ]
谢明星 [1 ]
机构
[1] Key Laboratory of Molecular Imaging of Hubei Province,Department of Ultrasound,Union Hospital,Tongji Medical College,Huazhong University of Science and Technology
[2] School of Pharmacy,Tongji Medical College,Huazhong University of Science and Technology
关键词
ultrasound triggered microbubble destruction; RNA interference; gene;
D O I
暂无
中图分类号
R440 [];
学科分类号
100208 ;
摘要
This study aimed to examine the preparation of cationic lipid microbubble(CLM),and evaluate its physical and chemical properties and toxicity,measure the gene transfection efficiency by ultrasound triggered microbobble destruction(UTMD) in combination with CLM.The CLM was prepared by the method of the thin film hydration,and its morphology was observed under the electron microscopy at 1st,3rd,7th,10th,and 14th day after preparation,respectively.The size,Zeta potential and stability of CLM were tested.The acute toxicity of CLM was assessed.The green fluorescent protein gene(EGFP) transfection efficiency was evaluated.The experiment grouping was as follows:naked plasmid group(P group),ultrasonic irradiation plus naked plasmid group(P-US group),naked plasmid plus CLM group(P-CLM group),naked plasmid plus ultrasound and CLM group(UTMD group).The expression of EGFP was detected by fluorescent microscopy and flow cytometry.The results showed that CLMs were spherical in shape,with the similar size and good distribution degree under the light and electron microscopies.The size of CLMs was varied from 250.4±88.3 to 399.0±99.8 nm and the Zeta potential of CLMs from 18.80±4.97 to 20.1±3.1 mV.The EGFP expression was the strongest in the UTMD group,followed by the P-CLM group,P-US group and P group.Flow cytometry results were consistent with those of fluorescent microscopy.The transfection efficiency was substantially increased in the P-US group,P-CLM group and UTMD group as compared with that in the P group,almost 7 times,10 times and 30 times higher than that in the P group respectively.It is suggested that CLMs prepared by the method of thin film hydration are uniform in diameter,and proved non-toxic.UTMD combined with CLM can significantly increase the transfection efficiency of EGFP to targeted cells.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 50 条
  • [1] Ultrasound-triggered Microbubble Destruction in Combination with Cationic Lipid Microbubbles Enhances Gene Delivery
    Zhang, Li
    Liu, Yingying
    Xiang, Guangya
    Lv, Qing
    Huang, Gui
    Yang, Yali
    Zhang, Yanrong
    Song, Yue
    Zhou, Huan
    Xie, Mingxing
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2011, 31 (01) : 39 - 45
  • [2] Ultrasound-triggered microbubble destruction in combination with cationic lipid microbubbles enhances gene delivery
    Li Zhang
    Yingying Liu
    Guangya Xiang
    Qing Lv
    Gui Huang
    Yali Yang
    Yanrong Zhang
    Yue Song
    Huan Zhou
    Mingxing Xie
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2011, 31 : 39 - 45
  • [3] Microbubbles in ultrasound-triggered drug and gene delivery
    Hernot, Sophie
    Klibanov, Alexander L.
    ADVANCED DRUG DELIVERY REVIEWS, 2008, 60 (10) : 1153 - 1166
  • [4] Target tumor therapy in human gastric cancer cells through the combination of docetaxel-loaded cationic lipid microbubbles and ultrasound-triggered microbubble destruction
    Bin Lai
    Xi Ouyang
    Shengxun Mao
    Jiaqin Cao
    Honglang Li
    Song Li
    Jiwei Wang
    Functional & Integrative Genomics, 2023, 23
  • [5] Target tumor therapy in human gastric cancer cells through the combination of docetaxel-loaded cationic lipid microbubbles and ultrasound-triggered microbubble destruction
    Lai, Bin
    Ouyang, Xi
    Mao, Shengxun
    Cao, Jiaqin
    Li, Honglang
    Li, Song
    Wang, Jiwei
    FUNCTIONAL & INTEGRATIVE GENOMICS, 2023, 23 (01)
  • [6] IN VITRO GENE DELIVERY WITH ULTRASOUND-TRIGGERED POLYMER MICROBUBBLES
    Cochran, Michael
    Wheatley, Margaret A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (06): : 1102 - 1119
  • [7] Targeted gene delivery to the left ventricular myocardium using ultrasound-triggered microbubble destruction
    Shohet, R
    Chen, S
    Zhou, YT
    Wang, ZW
    Meidell, RS
    Unger, R
    Grayburn, PA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 444A - 444A
  • [8] Effect of Gambogic Acid-Loaded Porous-Lipid/PLGA Microbubbles in Combination With Ultrasound-Triggered Microbubble Destruction on Human Glioma
    Wang, Feng
    Dong, Lei
    Wei, Xixi
    Wang, Yongling
    Chang, Liansheng
    Wu, Hongwei
    Liu, Shuyuan
    Chang, Yuqiao
    Yin, Yaling
    Luo, Xiaoqiu
    Jia, Xiaojian
    Yan, Fei
    Li, Nana
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [9] A SIMPLE METHOD FOR QUANTIFYING ULTRASOUND-TRIGGERED MICROBUBBLE DESTRUCTION
    Hung, Shuo-Hui
    Yeh, Chih-Kuang
    Tsai, Tung-Hu
    Chen, Tom
    Chen, Ran-Chou
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (06): : 949 - 957
  • [10] Effect of docetaxel-loaded lipid microbubble in combination with ultrasound-triggered microbubble destruction on the growth of a gastric cancer cell line
    Lai, Bin
    Zhu, Peiqian
    Li, Honglang
    Hu, Lin
    Wang, Jiwei
    ONCOLOGY LETTERS, 2019, 18 (01) : 442 - 448