NH3laserTHzemissionunderopticalpumpingby“long”(~100μs)CO2laserpulses

被引:2
作者
Andrey Alekseevich Ionin
Igor Olegovich Kinyaevskiy
Yuri Mikhailovich Klimachev
Andrey Yurievich Kozlov
Darya Ivanovna Kormashova
Andrey Alexandrovich Kotkov
Yury Alekseevich Mityagin
Sergey Alexandrovich Savinov
Adilya Maratovna Sagitova
Dmitry Vasilievich Sinitsyn
Maxim Vladimirovich Ionin
机构
[1] PNLebedevPhysicalInstituteoftheRussianAcademyofSciences
关键词
D O I
暂无
中图分类号
TN248 [激光器];
学科分类号
0803 ; 080401 ; 080901 ;
摘要
Terahertz (THz) NH3 lasing with optical pumping by electron-beam-sustained discharge“long”(~100μs) CO2 laser pulses was obtained.The NH3laser emission pulses and the“long”pulses of the CO2 pump laser were simultaneously measured with nanosecond response time.The NH3 lasing duration and its delay with respect to the pump pulse were measured for various CO2 laser pulse energies.For the CO2 laser pump line 9R(30),three wavelengths of 67.2,83.8,and 88.9μm were recorded.For the CO2 laser pump line 9R(16),only a single NH3 laser line with a wavelength of 90.4μm was detected.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 12 条
[1]   Industrial Applications of Terahertz Sensing: State of Play [J].
Naftaly, Mira ;
Vieweg, Nico ;
Deninger, Anselm .
SENSORS, 2019, 19 (19)
[2]   High-power terahertz optically pumped NH3 laser for plasma diagnostics [J].
Mishchenko, V. A. ;
Petrushevich, Yu. V. ;
Sobolenko, D. N. ;
Starostin, A. N. .
PLASMA PHYSICS REPORTS, 2012, 38 (06) :460-465
[3]  
Terahertz spectroscopy: Its future role in medical diagnoses.[J].Edward Philip John Parrott;Yiwen Sun;Emma Pickwell-MacPherson.Journal of Molecular Structure.2011, 1
[4]   An Efficient High-energy Pulsed NH3 Terahertz Laser [J].
Jiu, Zhi-Xian ;
Zuo, Du-Luo ;
Miao, Liang ;
Cheng, Zu-Hai .
JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2010, 31 (12) :1422-1426
[5]   Efficient millimetre far infrared laser emissions in different molecular systems [J].
Marchetti, S ;
Martinelli, M ;
Simili, R ;
Fantoni, R ;
Giorgi, M .
INFRARED PHYSICS & TECHNOLOGY, 2000, 41 (04) :197-204
[6]  
New FIR Emissions in Ammonia by Pumping with a Line Narrowed High Pressure CO<Subscript>2</Subscript> Laser.[J].Marchetti S.;Simili R..International Journal of Infrared and Millimeter Waves.1999, 12
[7]   High-frequency temporal structure of laser and phase-conjugated signals in intracavity degenerate four-wave mixing of radiation from electron-beam-controlled discharge CO2 and CO lasers in their active media [J].
Beairsto, C ;
Walter, R ;
Ionin, AA ;
Kotkov, AA ;
Penny, R ;
Seleznev, LA ;
Squires, S .
QUANTUM ELECTRONICS, 1997, 27 (07) :614-620
[8]  
A high-power far-infrared NH<Subscript>3</Subscript> laser pumped in a three-mirror CO<Subscript>2</Subscript> laser cavity with optically-switched cavity-dumping.[J].Wilson T. E..International Journal of Infrared and Millimeter Waves.1993, 2
[9]  
Compact; high-power FIR NH<inf>3</inf>laser pumped in a CO<inf>2</inf>laser cavity.[J].H. Hirose;S. Kon.IEEE Journal of Quantum Electronics.1986, 9
[10]   A HIGH-POWER 140 GHZ AMMONIA LASER [J].
WOSKOBOINIKOW, P ;
MACHUZAK, JS ;
MULLIGAN, WJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1985, 21 (01) :14-17