Assessment of the accuracy of real-time continuous glucose monitoring system and its correlated factors

被引:0
|
作者
洛佩 [1 ]
机构
[1] Graduate Brigade,3rd Milit Med Univ
关键词
MBG; CGM; Assessment of the accuracy of real-time continuous glucose monitoring system and its correlated factors; MAGE; real; time;
D O I
暂无
中图分类号
R587.1 [糖尿病];
学科分类号
1002 ; 100201 ;
摘要
Objective To assess the factors that influence the accuracy of real-time continuous glucose monitoring system(RT-CGM).Methods A total of 79 diabetic patients wore RT-CGM for three days continuously while calibrating by interphalangeal glucose values 4-8 times a day.We counted matching rate of interphalangeal glucose values and RT-CGM probe value,and analyzed correlation of the matching rate with MAGE,SDBG,MBG,AUC10,AUC3.9,and NGE by Pearson correlation analysis and multiple linear
引用
收藏
页码:19 / 19
页数:1
相关论文
共 50 条
  • [31] PERFORMANCE OF A NEW REAL-TIME CONTINUOUS GLUCOSE MONITORING SYSTEM: A MULTICENTER PILOT STUDY
    Zhou, J.
    Zhang, S.
    Li, L.
    Wang, Y.
    Lu, W.
    Sheng, C.
    Li, Y.
    Bao, Y.
    Jia, W.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A72 - A73
  • [32] Evaluation of a Novel Real-Time Continuous Glucose-Monitoring System for Use in Cats
    Moretti, S.
    Tschuor, F.
    Osto, M.
    Franchini, M.
    Wichert, B.
    Ackermann, M.
    Lutz, T. A.
    Reusch, C. E.
    Zini, E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (01): : 120 - 126
  • [33] Performance of a new real-time continuous glucose monitoring system: A multicenter pilot study
    Zhou, Jian
    Zhang, Shuo
    Li, Liang
    Wang, Yufei
    Lu, Wei
    Sheng, Chunjun
    Li, Yiming
    Bao, Yuqian
    Jia, Weiping
    JOURNAL OF DIABETES INVESTIGATION, 2018, 9 (02): : 286 - 293
  • [34] UTILISATION OF INTERMITTENT AND REAL-TIME CONTINUOUS BLOOD GLUCOSE MONITORING IN THE IRISH HEALTHCARE SYSTEM
    Gorry, C.
    Smith, A.
    Doran, S.
    Clarke, S.
    Barry, M.
    VALUE IN HEALTH, 2023, 26 (12) : S265 - S265
  • [35] Real-time monitoring system for accuracy of precision seeder
    Song, Peng
    Zhang, Junxiong
    Li, Wei
    Zhang, Xiaochao
    Fang, Xianfa
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2011, 42 (02): : 71 - 74
  • [36] Postprandial instead of preprandial calibration allows better accuracy of real-time continuous glucose monitoring (CGM)
    Capel, I.
    Pons, B.
    Hernando, M. E.
    Garcia, G.
    Brugues, E.
    de Leiva, A.
    Gomez, E.
    Prados, A.
    Erdozain, L.
    Rigla, M.
    DIABETOLOGIA, 2007, 50 : S419 - S419
  • [37] The Accuracy and Efficacy of Real-Time Continuous Glucose Monitoring Sensor in Chinese Diabetes Patients: A Multicenter Study
    Zhou, Jian
    Lv, Xiaofeng
    Mu, Yiming
    Wang, Xianling
    Li, Jing
    Zhang, Xingguang
    Wu, Jinxiao
    Bao, Yuqian
    Jia, Weiping
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (08) : 710 - 718
  • [38] Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period
    Mohammed Abdul Wasiq
    Sushree Smita Behura
    Swaranjika Sahoo
    Santosh Kumar Panda
    European Journal of Pediatrics, 2023, 182 : 1083 - 1087
  • [39] Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period
    Wasiq, Mohammed Abdul
    Behura, Sushree Smita
    Sahoo, Swaranjika
    Panda, Santosh Kumar
    EUROPEAN JOURNAL OF PEDIATRICS, 2023, 182 (03) : 1083 - 1087
  • [40] Real-Time Continuous Glucose Monitoring in an Intensive Care Unit: Better Accuracy in Patients with Septic Shock
    Lorencio, Carol
    Leal, Yenny
    Bonet, Alfonso
    Bondia, Jorge
    Palerm, Cesar C.
    Tache, Abdo
    Sirvent, Josep-Maria
    Vehi, Josep
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (07) : 568 - 575