Effect of low-intensity pulsed ultrasound on posterolateral lumbar fusion of rabbit

被引:0
|
作者
Jian Wang [1 ]
Jian-Wei Li [1 ]
Lei Chen [1 ]
机构
[1] 3rd Department of Orthopedics,Rizhao People’s Hospital Affiliated to Shandong University
关键词
Low-intensity pulsed ultrasound; Lumbar posterolateral; Fusion; Ilium;
D O I
暂无
中图分类号
R68 [骨科学(运动系疾病、矫形外科学)];
学科分类号
1002 ; 100210 ;
摘要
Objective:To observe the effect of low-intensity pulsed ultrasound in the posterolateral Lumbar fusion of rabbit.Methods:A total of 48 New Zealand white rabbits were randomly divided into the observation group and control group,including the autogenous iliac observation group.artificial bone observation group,artificial bone control group and autogenous iliac control group according to the different bone grafting.The posterolateral lumbar fusion of rabbits in each group was analyzed and compared.Results:After 4 weeks of treatment using the low-intensity pulsed ultrasound,the fusion in the bone grafting area of observation group was good.There was the relatively dense fusion area between the right transverse process and artificial bone.The left transverse process had been completely fused,with the clear bone trabecula through the fusion area.There was no significant fusion sign in the control group.According to the fusion comparison between two groups,the fusion rale of the observation group was 83.3%and it was significantly higher than the one of the control group(37.5%).Results of the comparison were statistically significant(P<0.05).The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the iliac observation group were significantly higher than ones of the iliac control group(P<0.05).The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the artificial bone observation group were significantly higher than ones of the artificial bone control group(P<0.05).The expression of IL-1.IL-6 and IL-17 4 weeks after the treatment of the observation group was significantly lower than the one of the control group,with the statistical significance(P<0.05).It indicated that the treatment of low-intensity pulsed ultrasound could reduce the expression level of inflammatory factors.Conclusions:The low-intensity pulsed ultrasound can significantly increase the bone grafting fusion rate of the rabbit’s posterolateral lumbar fusion.The possible mechanism is that it promotes the lumbar posterolateral endochondral ossification and reduces the inflammatory reaction.
引用
收藏
页码:68 / 72
页数:5
相关论文
共 50 条
  • [1] Effect of low-intensity pulsed ultrasound on posterolateral lumbar fusion of rabbit
    Wang, Jian
    Li, Jian-Wei
    Chen, Lei
    ASIAN PACIFIC JOURNAL OF TROPICAL MEDICINE, 2015, 8 (01) : 68 - 72
  • [2] Effects of low-intensity pulsed ultrasound stimulation on porous hydroxyapatite blocks for posterolateral fusion of lumbar spine in rabbits
    Zhuo Xiang-long
    Lue Hong-bin
    Xu Da-qi
    Liu Bin
    Wang Xi-yang
    Zhang Ying
    Hu Jian-zhong
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2010, 20 (10) : 1921 - 1927
  • [3] Effects of low-intensity pulsed ultrasound stimulation on porous hydroxyapatite blocks for posterolateral fusion of lumbar spine in rabbits
    卓祥龙
    吕红斌
    徐大启
    刘彬
    王锡阳
    张莹
    胡建中
    TransactionsofNonferrousMetalsSocietyofChina, 2010, 20 (10) : 1921 - 1927
  • [4] Effects of Low-Intensity Pulsed Ultrasound on Spinal Pseudarthrosis Created by Nicotine Administration A Model of Lumbar Posterolateral Pseucarthrosis in Rabbits
    Liao, Jen-Chung
    Chen, Wen-Jer
    Niu, Chi-Chien
    Chen, Lih-Hui
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (06) : 1043 - 1050
  • [5] Role of low-intensity pulsed ultrasound on lumbar spondylolysis: A systematic review
    Tanveer, Fahad
    Arslan, Syed Asadullah
    Darain, Haider
    Ahmad, Ashfaq
    Gilani, Syed Amir
    Hanif, Asif
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2022, 72 (03) : 522 - 525
  • [6] Low-Intensity Pulsed Ultrasound Enhances Healing of Laminectomy Chip Bone Grafts on Spinal Fusion: A Model of Posterolateral Intertransverse Fusion in Rabbits
    Chen, Lih-Hui
    Liao, Jen-Chung
    Chen, Wen-Jer
    Lai, Po-Liang
    Keorochana, Gun
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (04): : 863 - 869
  • [7] Low-intensity pulsed ultrasound: Nonunions
    Dijkman, Bernadette G.
    Sprague, Sheila
    Bhandari, Mohit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2009, 43 (02) : 141 - 148
  • [8] EFFECT OF LOW-INTENSITY PULSED ULTRASOUND ON PREPUBERTAL RAT TESTIS
    HADDAD, S
    ANSELMOFRANCI, JA
    PETENUSCI, SO
    LAMANOCARVALHO, TL
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 1991, 24 (07) : 697 - 700
  • [9] Low-intensity pulsed ultrasound does not enhance distraction callus in a rabbit model
    Taylor, Kenneth F.
    Rafiee, Bahman
    Tis, John E.
    Inoue, Nozumu
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (459) : 237 - 245
  • [10] LOW-INTENSITY PULSED ULTRASOUND PROTECTS CARTILAGE IN EXPERIMENTAL RABBIT KNEE OSTEOARTHRITIS
    Ungur, R. A.
    Borda, I. M.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2024, 36 : S506 - S506