Effects of seismic devices on transverse responses of piers in the Sutong Bridge

被引:0
作者
Shen Xing [1 ]
Alfredo Camara [2 ]
Ye Aijun [1 ]
机构
[1] State Key Laboratory for Disaster Reduction in Civil Engineering,Tongji University
[2] Department of Civil and Engineering,City University,London,United Kingdom PhD
关键词
Sutong Bridge; cable-stayed bridge; seismic devices; transverse response; bridge piers; viscous fluid dampers(VFD); friction pendulum sliding bearings(FPSB); transverse yielding metallic dampers(TYMD);
D O I
暂无
中图分类号
U442.55 []; P315.9 [工程地震];
学科分类号
0814 ; 081406 ; 070801 ;
摘要
The Sutong Bridge in China opened to traffic in 2008, and is an arterial connection between the cities of Nantong and Suzhou. It is a cable-stayed bridge with a main span of 1,088 m. Due to a tight construction schedule and lack of suitable seismic devices at the time, fixed supports were installed between the piers and the girder in the transverse direction. As a result, significant transverse seismic forces could occur in the piers and foundations, especially during a return period of a 2500-year earthquake. Therefore, the piers, foundations and fixed bearings had to be designed extraordinarily strong. However, when larger earthquakes occur, the bearings, piers and foundations are still vulnerable. The recent rapid developments in seismic technology and the performance-based design approach offer a better opportunity to optimize the transverse seismic design for the Sutong Bridge piers. The optimized design can be applied to the Sutong Bridge(as a retrofit), as well as other bridges. Seismic design alternatives utilizing viscous fluid dampers(VFD), or friction pendulum sliding bearings(FPSB), or transverse yielding metallic dampers(TYMD) are thoroughly studied in this work, and the results are compared with those from the current condition with fixed transverse supports and a hypothetical condition in which only sliding bearings are provided on top of the piers(the girder can move "freely" in the transverse direction during the earthquake, except for frictional forces of the sliding bearings). Parametric analyses were performed to optimize the design of these proposed seismic devices. From the comparison of the peak bridge responses in these configurations, it was found that both VFD and TYMD are very effective in the reduction of transverse seismic forces in piers, while at the same time keeping the relative transverse displacements between piers and the box girder within acceptable limits. However, compared to VFD, TYMD do not interact with the longitudinal displacements of the girder, and have simpler details and lower initial and maintenance costs. Although the use of FPSB can also reduce seismic forces, it generally causes the transverse relative displacements to be higher than acceptable limits.
引用
收藏
页码:611 / 623
页数:13
相关论文
共 5 条
[1]  
Seismic Response of Bridge Isolated with Friction Pendulum Systems[J] . Tao Hong,Mei Jun Lu,Chu Wei Zhou,Jian Zhang.Applied Mechanics and Materials . 2013 (256)
[2]  
Pushover analysis for the seismic response prediction of cable-stayed bridges under multi-directional excitation[J] . A. Camara,M.A. Astiz.Engineering Structures . 2012
[3]  
Second-order inelastic analysis of cable-stayed bridges[J] . Huu-Tai Thai,Seung-Eock Kim.Finite Elements in Analysis & Design . 2011
[4]   Observed dynamic performance of the Yokohama-Bay Bridge from system identification using seismic records [J].
Siringoringo, DM ;
Fujino, Y .
STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (01) :226-244
[5]  
EXPERIMENTAL STUDY OF FPS SYSTEM IN BRIDGE SEISMIC ISOLATION[J] . P.TSOPELAS,M. C.CONSTANTINOU,Y. S.KIM,S.OKAMOTO.Earthquake Engng. Struct. Dyn. . 1998 (1)