A new visual acuity test on touchpad for vision screening in children

被引:0
作者
Elsa Di Foggia [1 ]
Noémie Stoll [2 ]
Hélène Meunier [3 ]
Adam Rimelé [4 ]
Pascal Ance [4 ]
Pierre-Henri Moreau [4 ]
Claude Speeg-Schatz [1 ]
Arnaud Sauer [1 ]
机构
[1] Ophthalmology Department, CHU Strasbourg
[2] Ophthalmology Department,CH Colmar
[3] Cognitive and Adaptative Neuroscience Laboratory
[4] Plateforme SILABE, Strasbourg University
关键词
D O I
暂无
中图分类号
R779.7 [小儿眼科学];
学科分类号
100212 ;
摘要
AIM:To validate a visual acuity(VA) test application on touchpad in the screening of pediatric population by comparing VA results obtained with conventional tests.METHODS:A cohort of 101 patients,44 girls and 57 boys with a median of 6.5 years old(3-10 years of age),presenting for eye examinations in Ophthalmology Department(Strasbourg,France) between November 1st,2018,and February 1st,2019 were enrolled.Monocular and binocular VA testing was performed on the subject using both a standard test and the touchpad application(Monoyer, "E" or,Pigassou depending of children s capacities).Patients were excluded if they were physically or mentally unable to use the touchpad.The duration of each tests,the painfulness,the comprehension,the attention of children during the test and test’s preferences were also evaluated.RESULTS:There was a good linear correlation and intra-class correlation coefficient [ICC=0.50(0.34.0.64)for binocular acuity,0.74(0.64.0.82) for right eyes and 0.525(0.37.0.66) for left eye].The standard errors of measurement were very low(0.08.0.05.0.08 for binocular VA,right eyes VA and left eyes VA,respectively).There was no difference between two tests for right eye(P=0.126);left eye(P=0.098) and binocular acuity(P=0.085).Non inferiority was proved for all binocular [-0.06(-0.09.-0.03)],right eye [-0.04(-0.07.-0.01)] and left eye [-0.06(-0.09,-0.02)] VA.The sensitivity and specificity,which correspond to the ability for our app to detect amblyopia,were 92% and 80% respectively.CONCLUSION:Our touchpad application represents an efficient and valid test of VA in children with a high specificity to detect visual impairment.
引用
收藏
页码:1436 / 1442
页数:7
相关论文
共 13 条
[1]   Validation of Peek Acuity application in pediatric screening programs in Paraguay [J].
Bryce de Venecia ;
Yasmin Bradfield ;
Ralph M?ller Trane ;
Alicia Bareiro ;
Miguel Scalamogna .
International Journal of Ophthalmology, 2018, 11 (08) :1384-1389
[2]  
Hillary K Rono,Andrew Bastawrous,David Macleod,Emmanuel Wanjala,Gian Luca Di Tanna,Helen A Weiss,Matthew J Burton.Smartphone-based screening for visual impairment in Kenyan school children: a cluster randomised controlled trial[J].The Lancet Global Health,2018
[3]  
Tariq M. Aslam,Humza J. Tahir,Neil R.A. Parry,Ian J. Murray,Kun Kwak,Richard Heyes,Mahani M. Salleh,Gabriela Czanner,Jane Ashworth.Automated Measurement of Visual Acuity in Pediatric Ophthalmic Patients Using Principles of Game Design and Tablet Computers[J].American Journal of Ophthalmology,2016
[4]   REPRODUCIBILITY AND COMPARISON OF VISUAL ACUITY OBTAINED WITH SIGHTBOOK MOBILE APPLICATION TO NEAR CARD AND SNELLEN CHART [J].
Phung, Lam ;
Gregori, Ninel Z. ;
Ortiz, Angelica ;
Shi, Wei ;
Schiffman, Joyce C. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (05) :1009-1020
[5]  
Hee-Jung S. Park,Christian Hampp,Alex Christoff,Sylvia H. Yoo.Validation of iPad-based simplified visual acuity testing in children[J].Journal of AAPOS,2014
[6]  
Keri N. Toner,Michael J. Lynn,T. Rowan Candy,Amy K. Hutchinson.The Handy Eye Check: a mobile medical application to test visual acuity in children[J].Journal of AAPOS,2014
[7]   Reliability and Validity of an Automated Computerized Visual Acuity and Stereoacuity Test in Children Using an Interactive Video Game [J].
Ma, Dae Joong ;
Yang, Hee Kyung ;
Hwang, Jeong-Min .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (01) :195-201
[8]   Amblyopia Risk Factor Prevalence [J].
Arnold, Robert W. .
JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2013, 50 (04) :213-217
[9]  
Zhao-Tian Zhang,Shao-Chong Zhang,Xiong-Gao Huang,Ling-Yi Liang.A Pilot Trial of the Ipad Tablet Computer as a Portable Device for Visual Acuity Testing[J].Journal of Telemedicine and Telecare,2013
[10]   Global cost of correcting vision impairment from uncorrected refractive error [J].
Fricke, T. R. ;
Holden, B. A. ;
Wilson, D. A. ;
Schlenther, G. ;
Naidoo, K. S. ;
Resnikoff, S. ;
Frick, K. D. .
BULLETIN OF THE WORLD HEALTH ORGANIZATION, 2012, 90 (10) :728-738