Structural behaviors of steel roof truss exposed to pool fire

被引:1
作者
陈长坤 [1 ,2 ]
张威 [1 ]
机构
[1] Institute of Disaster Prevention Science and Safety Technology,Central South University
[2] State Key Laboratory of Fire Science (University of Science and Technology of China)
关键词
steel roof truss; fire test; multi-zone model; finite element analysis;
D O I
暂无
中图分类号
TU391 [钢结构]; TU545 [防火材料];
学科分类号
081304 ; 081402 ; 0805 ; 080502 ;
摘要
Experimental research was conducted to study the structural behaviors of a steel roof truss model without fire-proof coating under pool fire conditions.The data of temperature distribution and displacements of typical members were obtained.It is found that the temperature distribution of environment inside the structure,which is found to be in accordance with the multi-zone model with height,has a decisive effect on the temperature evolution of steel members.Besides,it can also be observed that due to the restriction and coordination among the truss members in the localized fire,the maximum relative deflection,which occurs at the mid-span of the top chord,is relatively slight and has not exceeded 1 mm under experimental conditions.On the other hand,the column experiences a notable thermal expansion during the test.Then,a finite element model is presented and validated by the test results.
引用
收藏
页码:2054 / 2060
页数:7
相关论文
共 4 条
[1]   Slope stability analysis with nonlinear failure criterion [J].
Yang, XL ;
Yin, JH .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 2004, 130 (03) :267-273
[2]  
How did the WTC towers collapse: a new theory[J] . A.S. Usmani,Y.C. Chung,J.L. Torero. Fire Safety Journal . 2003 (6)
[3]  
Strength of ring-stiffened tubular T-joints in offshore structures—[J] . M.M.K Lee,A Llewelyn-Parry. Journal of Constructional Steel Research . 1999 (3)
[4]  
Eurocode3:Design of steel structures,part1-2:General rules-Structural fire design .2 European Committee for Standardization. BS EN1993-1-2 . 2005