Reliability of the measurement of glenoid bone defect in anterior shoulder instability

被引:1
作者
Wu YongGang [1 ,2 ,3 ,4 ]
Zhang HaiLong [1 ,2 ,3 ,4 ]
Hao YaFei [1 ,2 ,3 ,4 ]
Jiang ChunYan
机构
[1] Department of Sports Medicine
[2] Peking University Fourth School of Clinical Medicine
[3] Beijing
[4] China
关键词
Reliability; Glenoid bone defect; Inter-observer; Intra-observer; Intra-class correlation coefficients; Computed tomography;
D O I
暂无
中图分类号
I [文学];
学科分类号
05 ;
摘要
Background: The size of the glenoid bone defect is an important index in selecting the appropriate treatment for anterior shoulder instability. However, the reliability of glenoid bone defect measurement is controversial. The purpose of the present study was to investigate the reliabilities of measurements of the glenoid bone defect on computed tomography and to explore the predisposing factors leading to inconsistency of these measurements.Methods: The study population comprised 69 consecutive patients who underwent surgery for recurrent anterior shoulder dislocation in Peking University Fourth School of Clinical Medicine from March 2016 to January 2017. The glenoid bone defect was measured by three surgeons on ''self-confirmed’ and ''designated’ 3-D en-face views, and repeated after an interval of 3 months. Measurements included the ratio of the defect area to the best-fit circle area, and the ratio of the defect width to the diameter of the best-fit circle. The inter- and intra-observer reliabilities of the measurements were evaluated using intraclass correlation coefficients (ICCs). The maximum absolute inter- and intra-observer differences and the cumulative percentages of cases with inter- and intraobserver differences greater than these respective levels were calculated.Results: Almost all linear defect values were bigger than the areal defect values. The inter-observer ICCs for the areal defect were 0.557 and 0.513 in the ''self-confirmed’ group and 0.549 and 0.431 in the ''designated’ group. The inter-observer reliabilities for the linear defect were moderate or fair in the ''self-confirmed’ group (ICC = 0.446, 0.374) and ''designated’ group (ICC = 0.402, 0.327). The ICCs for intra-observer measurements were higher than those for inter-observer measurements. The respective maximum interand intra-observer absolute differences were 13.9% and 13.2% in the ''self-confirmed’ group, and 15.8% and 9.8% in the ''designated’ group.Conclusions: The areal measurement of the glenoid bone defect is more reliable than the linear measurement. The reliability of the glenoid defect areal measurement is moderate or worse, suggesting that a more accurate and objective measurement method is needed in both en-face view and best-fit circle determination. Subjective factors affecting the glenoid bone loss measurement should be minimized.
引用
收藏
页码:2559 / 2564
页数:6
相关论文
共 23 条
[1]  
A Clinical Comparison of Linear- and Surface Area–Based Methods of Measuring Glenoid Bone Loss[J] . Neil K. Bakshi,George A. Cibulas,Jon K. Sekiya,Asheesh Bedi.The American Journal of Sports Medicine . 2018 (10)
[2]   Epidemiology of glenohumeral dislocation and subsequent instability in an urban population [J].
Shields, David W. ;
Jefferies, James G. ;
Brooksbank, Andrew J. ;
Millar, Neal ;
Jenkins, Paul J. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (02) :189-195
[3]   The Effect of Scapula Tilt and Best-Fit Circle Placement When Measuring Glenoid Bone Loss in Shoulder Instability Patients [J].
Moroder, Philipp ;
Plachel, Fabian ;
Huettner, Anna ;
Ernstbrunner, Lukas ;
Minkus, Marvin ;
Boehm, Elisabeth ;
Gerhardt, Christian ;
Scheibel, Markus .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (02) :398-404
[4]   Estimation of anterior glenoid bone loss area using the ratio of bone defect length to the distance from posterior glenoid rim to the centre of the glenoid [J].
Shin, Sang-Jin ;
Jun, Bong Jae ;
Koh, Young Won ;
McGarry, Michelle H. ;
Lee, Thay Q. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (01) :48-55
[5]   Accuracy and Reliability of a Simple Calculation for Measuring Glenoid Bone Loss on 3-Dimensional Computed Tomography Scans [J].
Parada, Stephen A. ;
Eichinger, Josef K. ;
Dumont, Guillaume D. ;
Parada, Carrie A. ;
Greenhouse, Alyssa R. ;
Provencher, Matthew T. ;
Higgins, Laurence D. ;
Warner, Jon J. P. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (01) :84-92
[6]   Assessment and Evaluation of Glenoid Bone Loss [J].
Hamamoto, Jason T. ;
Leroux, Timothy ;
Chahla, Jorge ;
Bhatia, Sanjeev ;
Higgins, John D. ;
Romeo, Anthony A. ;
Yanke, Adam B. ;
Verma, Nikhil N. .
ARTHROSCOPY TECHNIQUES, 2016, 5 (04) :E947-E951
[7]  
Incidence of Shoulder Dislocations and the Rate of Recurrent Instability in Soldiers[J] . Joseph R. Kardouni,Craig J. McKinnon,Amee L. Seitz.Medicine & Science in Sports & Exercise . 2016
[8]  
Surgical versus nonoperative treatment in patients up to 18 years old with traumatic shoulder instability: a systematic review and quantitative synthesis of the literature[J] . Umile Giuseppe Longo,Just A. van der Linde,Mattia Loppini,Vito Coco,Rudolf W. Poolman,Vincenzo Denaro.Arthroscopy: The Journal of Arthroscopic and Rela . 2015
[9]   The Epidemiology of Primary Anterior Shoulder Dislocations in Patients Aged 10 to 16 Years [J].
Leroux, Timothy ;
Ogilvie-Harris, Darrell ;
Veillette, Christian ;
Chahal, Jaskarndip ;
Dwyer, Tim ;
Khoshbin, Amir ;
Henry, Patrick ;
Mahomed, Nizar ;
Wasserstein, David .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (09) :2111-2117
[10]  
Glenoid Diameter Is an Inaccurate Method for Percent Glenoid Bone Loss Quantification: Analysis and Techniques for Improved Accuracy[J] . Sanjeev Bhatia,Anil Saigal,Rachel M. Frank,Bernard R. Bach,Brian J. Cole,Anthony A. Romeo,Nikhil N. Verma.Arthroscopy: The Journal of Arthroscopic and Rela . 2015 (4)