Uncertainty analysis of flow rate measurement for multiphase flow using CFD

被引:2
|
作者
Joon-Hyung Kim [1 ,2 ]
Uk-Hee Jung [2 ]
Sung Kim [1 ,2 ]
Joon-Yong Yoon [1 ]
Young-Seok Choi [2 ,3 ]
机构
[1] Department of Mechanical Design Engineering,Hanyang University
[2] Thermal & Fluid System R&BD Group,Korea Institute of Industrial Technology
关键词
Multiphase flow; Measurement; Numerical analysis; Venturi meter; Gas volume fraction(GVF); Uncertainty; Multiphase flow model; Grace model;
D O I
暂无
中图分类号
O359 [多相流];
学科分类号
080704 ;
摘要
The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied in many industries.The flow of a liquid containing air is a representative example of a multiphase flow and exhibits complex flow characteristics.In particular,the greater the gas volume fraction(GVF),the more inhomogeneous the flow becomes.As a result,using a venturi meter to measure the rate of a flow that has a high GVF generates an error.In this study,the cause of the error occurred in measuring the flow rate for the multiphase flow when using the venturi meter for analysis by CFD.To ensure the reliability of this study,the accuracy of the multiphase flow models for numerical analysis was verified through comparison between the calculated results of numerical analysis and the experimental data.As a result,the Grace model,which is a multiphase flow model established by an experiment with water and air,was confirmed to have the highest reliability.Finally,the characteristics of the internal flow Held about the multiphase flow analysis result generated by applying the Grace model were analyzed to find the cause of the uncertainty occurring when measuring the flow rate of the multiphase flow using the venturi meter.A phase separation phenomenon occurred due to a density difference of water and air inside the venturi,and flow inhomogeneity happened according to the flow velocity difference of each phase.It was confirmed that this flow inhomogeneity increased as the GVF increased due to the uncertainty of the flow measurement.
引用
收藏
页码:698 / 707
页数:10
相关论文
共 50 条
  • [1] Uncertainty analysis of flow rate measurement for multiphase flow using CFD
    Kim, Joon-Hyung
    Jung, Uk-Hee
    Kim, Sung
    Yoon, Joon-Yong
    Choi, Young-Seok
    ACTA MECHANICA SINICA, 2015, 31 (05) : 698 - 707
  • [2] Uncertainty analysis of flow rate measurement for multiphase flow using CFD
    Joon-Hyung Kim
    Uk-Hee Jung
    Sung Kim
    Joon-Yong Yoon
    Young-Seok Choi
    Acta Mechanica Sinica, 2015, 31 : 698 - 707
  • [3] Sensitivity and Uncertainty Analysis for Parameterization of Multiphase Flow Models
    Berg, Steffen
    Unsal, Evren
    Dijk, Harm
    TRANSPORT IN POROUS MEDIA, 2021, 140 (01) : 27 - 57
  • [4] Sensitivity and Uncertainty Analysis for Parameterization of Multiphase Flow Models
    Steffen Berg
    Evren Unsal
    Harm Dijk
    Transport in Porous Media, 2021, 140 : 27 - 57
  • [5] Gas flow rate measurement in low-quality multiphase flows using Venturi and gamma ray
    Pan, Yanzhi
    Li, Chao
    Ma, Yugao
    Huang, Shanfang
    Wang, Dong
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2019, 100 : 319 - 327
  • [6] CFD modeling and analysis of the multiphase flow and performance of dense medium cyclones
    Kuang, Shibo
    Qi, Z.
    Yu, A. B.
    Vince, A.
    Barnett, G. D.
    Barnett, P. J.
    MINERALS ENGINEERING, 2014, 62 : 43 - 54
  • [7] Analysis of indusrial measurement uncertainty of the gas mass flow using the ultrasonic metering system
    Mohammed, Oulhadj
    Abdelkader, Harrouz
    Ali, Benatillah
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON APPLIED SMART SYSTEMS (ICASS), 2018,
  • [8] Structural displacement measurement using deep optical flow and uncertainty analysis
    Wen, Haifeng
    Dong, Ruikun
    Dong, Peize
    OPTICS AND LASERS IN ENGINEERING, 2024, 181
  • [9] Uncertainty analysis for multiphase flow: A case study for horizontal air-water flow experiments
    da Silva, Felipe Jaloretto
    da Silva, Guilherme Goncalves
    Biazussi, Jorge Luiz
    de Castro, Marcelo Souza
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 80
  • [10] Methodology for Characterizing Representativeness Uncertainty in Orifice Plate Mass Flow Rate Measurements Using CFD Simulations
    Otgonbaatar, Uuganbayar
    Baglietto, Emilio
    Todreas, Neil
    NUCLEAR SCIENCE AND ENGINEERING, 2016, 184 (03) : 430 - 440