Magnetic resonance imaging after cochlear implants

被引:0
|
作者
Naif Bawazeer [1 ]
Hella Vuong [2 ]
Sophie Riehm [3 ]
Francis Veillon [3 ]
Anne Charpiot [2 ]
机构
[1] Department of Otolaryngology-Head & Neck Surgery, Umm Al-Qura University
[2] Department of Otorhinolaryngology and Head and Neck Surgery, Hautepierre Hospital, University of Strasbourg
[3] Department of Radiology, Hautepierre Hospital, University of Strasbourg
关键词
MRI; Cochlear implant; Risk;
D O I
暂无
中图分类号
R764 [耳科学、耳疾病]; R445.2 [核磁共振成像];
学科分类号
100207 ; 100213 ;
摘要
Introduction: Most cochlear implants are currently compatible with magnetic resonance imaging(MRI) up to 3 T.Nevertheless, this does not completely eliminate the risk of serious accidents. Implant displacements and other adverse events with compatible implants have been reported in the literature.Case reports: Among the six patients who had MRI after receiving implants at our center, we report three cases with adverse events related to the examination. The first case was complicated by magnet displacement with partial demagnetization. The second case showed total demagnetization, which necessitated removal and reimplantation of the implant. The third case involved severe pain sensation which disrupted the MRI scan. The smallest artifact was found with 3D MRI angiography, and largest artifact was found with diffusion and T2 FLASH.Discussion: Moving the patient into the MRI apparatus must be supervised by an otorhinolaryngology specialist or an experienced radiologist. It is important to consider the magnetic field directions, so that angle between the implant magnetic fields and the MRI B0 always remains less than or equal to 90°. In addition, we recommend the use of an "arrow drawing" to facilitate the orientation of the magnetic field directions. Furthermore, to prevent magnet displacement, we recommend systematic use of a protective splint in addition to bandaging.
引用
收藏
页码:22 / 25
页数:4
相关论文
共 50 条
  • [1] Magnetic resonance imaging after cochlear implants
    Bawazeer, Naif
    Vuong, Hella
    Riehm, Sophie
    Veillon, Francis
    Charpiot, Anne
    JOURNAL OF OTOLOGY, 2019, 14 (01) : 22 - 25
  • [2] COCHLEAR IMPLANTS AS A CONTRAINDICATION TO MAGNETIC-RESONANCE-IMAGING
    PORTNOY, WM
    MATTUCCI, K
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (03): : 195 - 197
  • [3] Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects
    Teissl, C
    Kremser, C
    Hochmair, ES
    Hochmair-Desoyer, IJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (01) : 26 - 38
  • [4] Dimensions of artefacts caused by cochlear and auditory brainstem implants in magnetic resonance imaging
    Majdani, Elham
    Majdani, Omid
    Steffens, Melanie
    Warnecke, Athanasia
    Lesinski-Schiedat, Anke
    Lenarz, Thomas
    Goetz, Friedrich
    COCHLEAR IMPLANTS INTERNATIONAL, 2020, 21 (02) : 67 - 74
  • [5] Magnetic resonance imaging safety of Nucleus® 24 cochlear implants at 3.0 T
    Risi, F
    Saldanha, A
    Leigh, R
    Gibson, P
    COCHLEAR IMPLANTS, 2004, 1273 : 394 - 398
  • [6] Magnetic resonance imaging with cochlear implants and auditory brainstem implants: Are we truly practicing MRI safety?
    Shew, Matthew
    Wichova, Helena
    Lin, James
    Ledbetter, Luke N.
    Staecker, Hinrich
    LARYNGOSCOPE, 2019, 129 (02): : 482 - 489
  • [7] Magnetic Resonance Imaging at 1.5 T After Cochlear Implantation
    Crane, Benjamin T.
    Gottschalk, Barbara
    Kraut, Michael
    Aygun, Nafi
    Niparko, John K.
    OTOLOGY & NEUROTOLOGY, 2010, 31 (08) : 1215 - 1220
  • [8] Magnetic resonance imaging safety of the Combi 40 Combi 40+ cochlear implants
    Hochmair, ES
    Teissl, C
    Kremser, C
    Hochmair-Desoyer, I
    UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 39 - 41
  • [9] Reversing the polarity of a cochlear implant magnet after magnetic resonance imaging
    Jeon, Ju Hyun
    Bae, Mi Ran
    Chang, Jae Won
    Choi, Jae Young
    AURIS NASUS LARYNX, 2012, 39 (04) : 415 - 417
  • [10] The reversed internal magnet of cochlear implant after magnetic resonance imaging
    Kong, Soo-Keun
    Oh, Se-Joon
    Lee, Il-Woo
    Goh, Eui-Kyung
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2014, 35 (02) : 239 - 241