Fast magnetic reconstruction of the portal vein with allogeneic blood vessels in canines

被引:0
作者
Shan-Pei Wang
Xiao-Peng Yan
Fei Xue
Ding-Hui Dong
Xu-Feng Zhang
Feng Ma
Hao-Hua Wang
Yi Lv
机构
[1] XJTU Research Institute of Advanced Surgical Technology and Engineering
[2] Department of Hepatobiliary Surgery, First Affiliated Hospital, Medical School of Xi’an Jiaotong University
[3] Regenerative Medicine and Surgery Engineering Research Center of Shaanxi Province
基金
中国国家自然科学基金;
关键词
magnetic compression anastomosis; portal vein reconstruction; non-suture anastomosis;
D O I
暂无
中图分类号
R657.34 [];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND:The resection and reconstruction of large vessels,including the portal vein,are frequently needed in tumor resection.Warm ischemia before reconstruction might have deleterious effects on the function of some vital organs and therefore,how to reconstruct the vessels quickly after resection is extremely important.The present study was to introduce a new type of magnetic compression anastomosis(MCA)device to establish a quick non-suture anastomosis of the portal vein after resection in canines.METHODS:The new MCA device consists of a pair of titanium alloy and neodymium-ferrum-boron magnet(Ti-Nd Fe B)composite rings.The Nd Fe B magnetic ring as a core of the device was hermetically sealed inside the biomedical titanium alloy case.Twelve canines were divided into two groups:a MCA group in which the end-to-end anastomoses was made with a new device after resection in the portal vein and a traditional manual suture(TMS)group consisted of 6 canines.The anastomosis time,anastomotic patency and quality were investigated at week 24 postoperatively.RESULTS:The portal vein was reconstructed successfully in all of the animals and they all survived.The duration of portal vein anastomosis was significantly shorter in the MCA group than in the TMS group(8.16±1.25 vs 36.24±2.17 min,P<0.05).Portography and ultrasound showed that the blood flow was normal without angiostenosis or thrombosis in all of the canines.Hematoxylin-eosin staining and electron microscope scanning showed in contrast to the TMS group,MCA anastomotic intimal was much smoother with more regularly arranged endothelial cells at week 24 postoperatively.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 14 条
[1]  
A new veno-venous bypass type for ex-vivo liver resection in dogs[J]. Peng Lei,Shi-Qi Liu,Xiao-Hai Cui,Yi Lv,Ge Zhao,Jian-Hui Li.Hepatobiliary & Pancreatic Diseases International. 2013(04)
[2]  
Tips and tricks of surgical technique for pancreatic cancer: portal vein resection and reconstruction (with videos)[J] . Hideyuki Yoshitomi,Atsushi Kato,Hiroaki Shimizu,Masayuki Ohtsuka,Katsunori Furukawa,Tsukasa Takayashiki,Satoshi Kuboki,Shigetsugu Takano,Daiki Okamura,Daisuke Suzuki,Nozomu Sakai,Shingo Kagawa,Masaru Miyazaki.J Hepatobiliary Pancreat Sci . 2014 (9)
[3]  
Portal Vein Resection in Borderline Resectable Pancreatic Cancer: A United Kingdom Multicenter Study[J] . Reena Ravikumar,Caroline Sabin,Mohammad Abu Hilal,Simon Bramhall,Steven White,Stephen Wigmore,Charles J. Imber,Giuseppe Fusai,Robert Hutchins,Michael Silva,John Simpson,David Stell,Massimo Malago,Yogesh Puri,Giuseppe Preziosi,Ali -Al-Hilli,Chris Coldham,Aimen Saleh,John Terrace,Qaiser Jalal,Giles Bond-Smith,Gabriele Spoletini,John Hammond,Somaiah Aroori.Journal of the American College of Sur
[4]  
Use of a temporary intraoperative mesenterico-portal shunt for pancreatic resection for locally advanced pancreatic cancer with portal vein occlusion and portal hypertension[J] . Philippe Bachellier,Edoardo Rosso,P. Fuchshuber,Pietro Addeo,Patrice David,Elie Oussoultzoglou,Ian Lucescu.Surgery . 2013
[5]  
Sutureless Anastomoses Using Magnetic Rings in Canine Liver Transplantation Model[J] . Shi-Qi Liu,Peng Lei,Xiao-Hai Cui,Yi Lv,Jian-Hui Li,Yu-Long Song,Ge Zhao.Journal of Surgical Research . 2013
[6]  
The LINX? reflux management system: confirmed safety and efficacy now at 4?years[J] . John Lipham,Tom DeMeester,Robert Ganz,Luigi Bonavina,Greta Saino,Daniel Dunn,Paul Fockens,Willem Bemelman.Surgical Endoscopy . 2012 (10)
[7]  
Creation of Transcatheter Aortopulmonary and Cavopulmonary Shunts Using Magnetic Catheters: Feasibility Study in Swine[J] . Daniel S. Levi,Saar Danon,Brent Gordon,Nicky Virdone,Fernando Vinuela,Sanjay Shah,Greg Carman,John W. Moore.Pediatric Cardiology . 2009 (4)
[8]  
Use of a magnetic sphincter for the treatment of GERD: a feasibility study[J] . Robert A. Ganz,Christopher J. Gostout,Jerry Grudem,William Swanson,Todd Berg,Tom R. DeMeester.Gastrointestinal Endoscopy . 2008 (2)
[9]   Vein graft anastomoses with magnets [J].
Heitmann, Christoph ;
Khan, Farah N. ;
Erdmann, Detlev ;
Olbrich, Kevin C. ;
Sharkawy, A. Adam ;
Klitzman, Bruce .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2007, 60 (12) :1296-1301
[10]   Novel magnetic rings for rapid vascular reconstruction in canine liver transplantation model [J].
Shi, Y. ;
Lv, Y. ;
Wang, B. ;
Zhang, Y. ;
Jiang, A. ;
Li, J. H. ;
Zhang, X. F. ;
Li, Q. Y. ;
Meng, K. W. ;
Liu, C. ;
Yu, L. ;
Pan, C. E. .
TRANSPLANTATION PROCEEDINGS, 2006, 38 (09) :3070-3074