Numerical simulation and experiment of error field measurement using luminous trace of electron beam in SST-1

被引:0
|
作者
Someswar DUTTA [1 ]
Y PARAVASTU [1 ]
J DHONGDE [1 ]
H CHUDASMA [1 ]
S GEORGE [1 ]
K DHANANI [1 ]
A MAKWANA [1 ]
C DODIYA [1 ]
P VARMORA [1 ]
D K SHARMA [1 ]
A K SINGH [1 ]
U KUMAR [1 ]
D RAVAL [1 ]
U PRASAD [1 ]
Z KHAN [1 ]
R SRINIVASAN [1 ,2 ]
D RAJU [1 ]
机构
[1] Institute for Plasma Research
[2] Homi Bhabha National Institute(HBNI)
关键词
electron beam; error field; SST-1; TF coil;
D O I
暂无
中图分类号
TL631.24 [];
学科分类号
082701 ;
摘要
In contrast to the earlier experiments conducted in other machines,here,in SST-1 the error field measurement experiment is performed with a filled gas pressure ~8×10-4mbar which helped to create a luminescent toroidal beam of electron path originated due to impact excitation and guided by the toroidal magnetic field.Beam path deviations are observed and recorded from radial and top ports using visible range cameras.Such creation and detection of the electron beam path differs from the earlier works where the gun emitted electron beam deviation in ultrahigh vacuum was detected on a collector-grid/fluorescent screen.In the present experiment,large beam deviations were observed.Later investigation of the experimental set-up reveals existence of a possible source of radial electric field in between the source and the vacuum vessel which are separately grounded.Thus,to understand the observed phenomena,experiments are numerically modeled with deviated TF coil set,PF coil set and the electron source location.A particle tracing code is used to follow the electron path in the magnetic field generated by the coil set of interest.Simulation results suggest that the large deviation corresponds to the E×B drifts and not due to the large field errors.Toroidally averaged field errors of the SST-1 TF coils at toroidal field of B0=15 kG are negligibly small~B0×10-6or less,which should not adversely affect the plasma performance.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 3 条
  • [1] Numerical simulation and experiment of error filed measurement using luminous trace of electron beam in SST-1
    Dutta, Someswar
    Paravastu, Y.
    Dhongde, J.
    Chudasma, H.
    George, S.
    Dhanani, K.
    Makwana, A.
    Dodiya, C.
    Varmora, P.
    Sharma, D. K.
    Singh, A. K.
    Kumar, U.
    Raval, D.
    Prasad, U.
    Khan, Z.
    Srinivasan, R.
    Raju, D.
    PLASMA SCIENCE & TECHNOLOGY, 2019, 21 (10)
  • [2] Design of an ion extractor system for a prototype ion source experiment for SST-1 neutral beam injector
    Jana, M. R.
    Bandyopadhaya, M.
    Singh, N. P.
    Sharma, S. K.
    Chakraborty, A. K.
    Baruah, U. K.
    Mattoo, S. K.
    FUSION ENGINEERING AND DESIGN, 2010, 85 (01) : 122 - 125
  • [3] Design of Soft X-ray Tube and Simulation of Electron Beam by Using an Electromagnetic Finite Element Method for Elimination of Static Electric Field
    Park, Tae-Young
    Lee, Sang-Suk
    Park, Rae-Jun
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2014, 24 (02): : 66 - 69