Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model

被引:0
作者
Wang Hong-Yang
Liu Long-Shan
Cao Hai-Ming
Li Jun
Deng Rong-Hai
Fu Qian
Zhang Huan-Xi
Fei Ji-Guang
Wang Chang-Xi
机构
[1] Organ Transplant Center, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong 510080, China
[2] Guangdong Provincial Key Laboratory on Organ Donation and Transplant Immunology, Guangzhou, Guangdong 510080, China
关键词
Hemodynamics; Kidney Transplantation; Patient-specific Modeling; Renal Artery Obstruction;
D O I
暂无
中图分类号
R699.2 [肾脏手术];
学科分类号
1002 ; 100210 ;
摘要
Background: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Methods: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann–WhitneyU-test was used for analysis.Results: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole,P= 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole,P= 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole,P = 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole,P = 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS.Conclusions: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 31 条
  • [1] Compound ex vivo and in silico method for hemodynamic analysis of stented arteries..[J].Farhad Rikhtegar;Fernando Pacheco;Christophe Wyss;Kathryn S Stok;Heng Ge;Ryan J Choo;Aldo Ferrari;Dimos Poulikakos;Ralph Müller;Vartan Kurtcuoglu.PLoS ONE.2017, 3
  • [2] Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations
    Qiao, Aike
    Dai, Xuan
    Niu, Jing
    Jiao, Liqun
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (11) : 1190 - 1200
  • [3] Flow pattern analysis in a highly stenotic patient-specific carotid bifurcation model using a turbulence model
    Li, Zhi-Yong
    Tan, Felicia P. P.
    Soloperto, Giulia
    Wood, Nigel B.
    Xu, Xiao Y.
    Gillard, Jonathan H.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (10) : 1099 - 1107
  • [4] Transplant renal artery stenosis: clinical manifestations; diagnosis and therapy.[J].Chen Wei;Kayler Liise K.;Zand Martin S.;Muttana Renu;Chernyak Victoria;DeBoccardo Graciela O..Clinical Kidney Journal.2014, 1
  • [5] Numerical investigations of pulsatile flow in stenosed artery
    Bit, Arindam
    Chattopadhyay, Himadri
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2014, 16 (04) : 33 - 44
  • [6] Transplant renal artery stenosis in children: risk factors and outcome after endovascular treatment
    Ghirardo, Giulia
    De Franceschi, Marco
    Vidal, Enrico
    Vidoni, Alessandro
    Ramondo, Gaetano
    Benetti, Elisa
    Motta, Raffaella
    Ferraro, Alberto
    Zanon, Giovanni Franco
    Miotto, Diego
    Murer, Luisa
    [J]. PEDIATRIC NEPHROLOGY, 2014, 29 (03) : 461 - 467
  • [7] Hemodynamic analysis of renal artery stenosis using computational fluid dynamics technology based on unenhanced steady-state free precession magnetic resonance angiography: preliminary results.[J].Weisheng Zhang;Yi Qian;Jiang Lin;Peng Lv;Kaavya Karunanithi;Mengsu Zeng.The International Journal of Cardiovascular Imaging.2014, 2
  • [8] Postanastomotic Transplant Renal Artery Stenosis: Association With De Novo Class II Donor-Specific Antibodies
    Willicombe, M.
    Sandhu, B.
    Brookes, P.
    Gedroyc, W.
    Hakim, N.
    Hamady, M.
    Hill, P.
    McLean, A. G.
    Moser, S.
    Papalois, V.
    Tait, P.
    Wilcock, M.
    Taube, D.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 (01) : 133 - 143
  • [9] Hemodynamics in coronary arteries with overlapping stents
    Rikhtegar, Farhad
    Wyss, Christophe
    Stok, Kathryn S.
    Poulikakos, Dimos
    Mueller, Ralph
    Kurtcuoglu, Vartan