Evaluating newer generation intraocular lens calculation formulas in manual versus femtosecond laser-assisted cataract surgery

被引:2
作者
Harrish Nithianandan [1 ]
Soumya Sharma [2 ]
Eric S.Tam [3 ,4 ,5 ]
Hannah Chiu [3 ,4 ,5 ]
Rajiv Maini [4 ]
Sohel Somani [3 ,4 ,5 ]
机构
[1] Department of Ophthalmology & Visual Sciences, McGill University
[2] Ryerson University
[3] Department of Ophthalmology, University of Toronto
[4] Uptown Eye Specialists
[5] William Osler Health System
关键词
phacoemulsification; cataract; femtosecond laser; intraocular lens;
D O I
暂无
中图分类号
R779.6 [眼外科手术学];
学科分类号
100212 ;
摘要
AIM: To determine the refractive accuracy of the Haigis,Barrett Universal II(Barrett), and Hill-radial basis function 2.0(Hill-RBF) intraocular lens(IOL) power calculations formulas in eyes undergoing manual cataract surgery(MCS)and refractive femtosecond laser-assisted cataract surgery(Re LACS).METHODS: This was a REB-approved, retrospective interventional comparative case series of 158 eyes of 158 patients who had preoperative biometry completed using the IOL Master 700 and underwent implantation of a Tecnis IOL following uncomplicated cataract surgery using either MCS or ReLACS. Target spherical equivalence(SE) was predicted using the Haigis, Barrett, and Hill-RBF formulas.An older generation formula(Hoffer Q) was included in the analysis. Mean refractive error(ME) was calculated one month postoperatively. The lens factors of all formulas were retrospectively optimized to set the ME to 0 for each formula across all eyes. The median absolute errors(MedAE)and the proportion of eyes achieving an absolute error(AE)within 0.5 diopters(D) were compared between the two formulas among MCS and ReLACS eyes, respectively.RESULTS: Of the 158 eyes studied, 64 eyes underwent MCS and 94 eyes underwent ReLACS. Among MCS eyes,the MedAE did not differ between the formulas(P=0.59),however among ReLACS eyes, Barrett and Hill-RBF were more accurate(P=0.001). Barrett and Hill-RBF were both more likely to yield AE<0.5 D among both groups(P<0.001).CONCLUSION: The Barrett and Hill-RBF formula lead to greater refractive accuracy and likelihood of refractive success when compare to Haigis in eyes undergoing Re LACS.
引用
收藏
页码:1174 / 1178
页数:5
相关论文
共 14 条
  • [1] Kelvin H. Wan,Thomas C.H. Lam,Marco C.Y. Yu,Tommy C.Y. Chan.Accuracy and Precision of Intraocular Lens Calculations Using the New Hill-RBF Version 2.0 in Eyes With High Axial Myopia[J].American Journal of Ophthalmology,2019
  • [2] Ankur K. Shrivastava,Pranayee Behera,Binod Kumar,Siddhartha Nanda.Precision of intraocular lens power prediction in eyes shorter than 22 mm: An analysis of 6 formulas[J].Journal of Cataract & Refractive Surgery,2018
  • [3] Wang Qiwei,Jiang Wu,Lin Tiao,Wu Xiaohang,Lin Haotian,Chen Weirong.Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes[J].Clinical & experimental ophthalmology,2018
  • [4] Roberts Timothy V,Hodge Chris,Sutton Gerard,Lawless Michael.Comparison of Hill-radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery[J].Clinical & experimental ophthalmology,2018
  • [5] Wang Qiwei,Jiang Wu,Lin Tiao,Zhu Yi,Chen Chuan,Lin Haotian,Chen Weirong.Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis[J].Clinical & experimental ophthalmology,2018
  • [6] Ronald B. Melles,Jack T. Holladay,William J. Chang.Accuracy of Intraocular Lens Calculation Formulas[J].Ophthalmology,2018
  • [7] Sabite E. Gökce,John H. Zeiter,Mitchell P. Weikert,Douglas D. Koch,Warren Hill,Li Wang.Intraocular lens power calculations in short eyes using 7 formulas[J].Journal of Cataract & Refractive Surgery,2017
  • [8] Marko Popovic,Xavier Campos-Möller,Matthew B. Schlenker,Iqbal Ike K. Ahmed.Efficacy and Safety of Femtosecond Laser-Assisted Cataract Surgery Compared with Manual Cataract Surgery[J].Ophthalmology,2016
  • [9] Jack X. Kane,Anton Van Heerden,Alp Atik,Constantinos Petsoglou.Intraocular lens power formula accuracy: Comparison of 7 formulas[J].Journal of Cataract & Refractive Surgery,2016
  • [10] David L. Cooke,Timothy L. Cooke.Comparison of 9 intraocular lens power calculation formulas[J].Journal of Cataract & Refractive Surgery,2016