Noise exposure assessment with task-based measurement in complex noise environment

被引:0
作者
LI NanYANG QiulingZENG LinZHU LiangliangTAO LiyuanZHANG Hua and ZHAO Yiming Research Center of Clinical Epidemiology Research Center of Occupational Medicine Peking University Third HospitalBeijing China Dongfeng Occupational Disease Prevention and Treatment Institute of ShiyanShiyanHubei China [100191 ,442001 ]
机构
关键词
D O I
暂无
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
<正> Background Task-based measurement (TBM) is a method to assess the eight-hour A-weighted equivalent noiseexposure level (LAeq.8h) besides dosimeter. TBM can be better used in factories by non-professional workers and staffs.However, it is still not clear if TBM is equal or similar with dosimeter for LAeq.8h measurement in general. This studyconsidered the measurement with dosimeter as real personal noise exposure level (PNEL) and assessed the accuracy ofTBM by comparing the consistencies of TBM and dosimeter in LAeq.8h measurement.Methods The study was conducted in one automobile firm among 387 workers who are exposed to unstable noise.Dosimeters and TBM were used to compare the two strategies and assess the degree of agreement and causes ofdisagreement. Worker's PNEL was measured via TBM for noise; the real PNEL was also recorded. The TBM for noisewas computed with task/position noise levels measured via sound level meter and workers' exposure informationcollected via working diary forms (WDF) filled by participants themselves. Full-shift noise exposure measurement viapersonal noise dosimeters were taken as the real PNEL. General linear model (GLM) was built to analyze the accuracy ofTBM for noise and the source of difference between TBM for noise and real PNEL.Results The LAeq.8h with TBM were slightly higher than the real PNELs, except the electricians. Differences of the twovalues had statistical significance in stamping workers (P <0.001), assembly workers (P=0.015) and welding workers(P=0.001). The correlation coefficient of LAeq.8h.8h with TBM and real PNELs was 0.841. Differences of the two results weremainly affected by real PNEL (F=11.27, P=0.001); and work groups (F=3.11, P<0.001) divided by jobs and workshopswere also independent factors. PNEL of workers with fixed task/position ((86.53±8.82) dB(A)) was higher than thosewithout ((75.76+9.92) dB(A)) (7=8.84, P <0.01). Whether workers had fixed task/position was another factor on theaccuracy of TBM for noise (F=4.36, P=0.038).Conclusion TBM for noise has acceptable accuracy on workers' PNEL measurement. The accuracy is affected by jobcategories, workshops and variability of task/position. TBM for noise can yield a relatively conservative result of worker'sPNEL in most cases, so it can be used to measure and assess workers' real PNEL.
引用
收藏
页码:1346 / 1351
相关论文
共 10 条
[1]  
Assessment of personal noise exposure of overhead-traveling crane drivers in steel-rolling mills[J]. ZENG Lin CHAI Dong-liang LI Hui-juan LEI Zhuo ZHAO Yi-ming Research Center of Occupational Medicine,Peking University Third Hospital,Beijing 100083,ChinaDepartment of Occupational Health,Center for Disease Control and Prevention,Taiyuan Iron & Steel (Group) Company LTD.,Taivyuan 030003,China. Chinese Medical Journal. 2007(08)
[2]   机场机坪地勤人员噪声暴露的测量与评价 [J].
黄云兰 ;
祝文杰 ;
邵良洪 ;
王建新 ;
艾丽萍 ;
杨毅 ;
吕旌乔 ;
赵一鸣 .
工业卫生与职业病, 2003, (06) :326-328
[3]   同一车间中冲压工和下料工个体噪声暴露的测量与评价 [J].
陈山松 ;
成小如 ;
李玉秦 ;
杨进伟 ;
赵一鸣 .
中国职业医学, 2003, (04) :6-8
[4]  
Hemostatic Agents Injected Directly Into Hepatic Injury Sites for Liver Trauma Hemorrhage Under the Guidance of Contrast-Enhanced Ultrasound: An Animal Experiment[J] . Faqin Lv,Jie Tang,Wenxiu Li,Huiqin Zhang,Wei Wang,Li Yang. Ultrasound in Medicine & Biology . 2008 (10)
[5]  
Effect of BioGlue? on the Incidence of Pancreatic Fistula Following Pancreas Resection[J] . William E. Fisher,Christy Chai,Sally E. Hodges,Meng-Fen Wu,Susan G. Hilsenbeck,F. Charles Brunicardi. Journal of Gastrointestinal Surgery . 2008 (5)
[6]   Preventable or potentially preventable mortality at a mature trauma center [J].
Teixeira, Pedro G. R. ;
Inaba, Kenji ;
Hadjizacharia, Pantelis ;
Brown, Carlos ;
Salim, Ali ;
Rhee, Peter ;
Browder, Timothy ;
Noguchi, Thomas T. ;
Demetriades, Demetrios .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (06) :1338-1346
[7]  
Extremity Vascular Injuries on the Battlefield: Tips for Surgeons Deploying to War[J] . Benjamin W. Starnes,Alec C. Beekley,James A. Sebesta,Charles A. Andersen,Robert M. Rush. The Journal of Trauma: Injury, Infection, and Critical Care . 2006 (2)
[8]   Release of glutaraldehyde from an albumin-glutaraldehyde tissue adhesive causes significant in vitro and in vivo toxicity [J].
Fürst, W ;
Banerjee, A .
ANNALS OF THORACIC SURGERY, 2005, 79 (05) :1522-1529
[9]  
Clinical benefits and risk analysis of topical hemostats: a review[J] . Yasuko Tomizawa. Journal of Artificial Organs . 2005 (3)
[10]  
Comparative study of microfibrillar collagen hemostat (Colgel) and oxidized cellulose (Surgicel) in high transfusion-risk cardiac surgery[J] . Mustafa Sirlak,Sadik Eryilmaz,Levent Yazicioglu,Ugursay Kiziltepe,Zeynep Eyileten,Mustafa Serkan Durdu,Refik Tasoz,Neyyir Tuncay Eren,Atilla Aral,Bulent Kaya,Hakki Akalin. The Journal of Thoracic and Cardiovascular Surgery . 2003 (3)