Establishing an Initial Electron Beam Model with Monte Carlo Simulation for a Single 6 MV X-ray Medical Linac Based on Particle Dynamics Characteristics

被引:0
|
作者
ZHAO Hong-bin1
机构
关键词
initial electron beam model; particle dynamic calculation; Monte Carlo simulation; medical linear accelerator;
D O I
暂无
中图分类号
R318.0 [一般性问题];
学科分类号
0831 ;
摘要
Objective:In this study,we try to establish an initial electron beam model by combining Monte Carlo simulation method with particle dynamic calculation(TRSV)for the single 6 MV X-ray accelerating waveguide of BJ-6 medical linac.Methods and Materials:1.We adapted the treatment head configuration of BJ-6 medical linac made by Beijing Medical Equipment Institute(BMEI)as the radiation system for this study.2.Use particle dynamics calculation code called TRSV to drive out the initial electron beam parameters of the energy spectrum,the spatial intensity distribution,and the beam incidence angle.3.Analyze the 6 MV X-ray beam characteristics of PDDc,OARc in a water phantom by using Monte Carlo simulation(BEAMnrc,DOSXYZnrc)for a preset of the initial electron beam parameters which have been determined by TRSV,do the comparisons of the measured results of PDDm,OARm in a real water phantom,and then use the deviations of calculated and measured results to slightly modify the initial electron beam model back and forth until the deviations meet the error less than 2%.Results:The deviations between the Monte Carlo simulation results of percentage depth doses at PDDc and off-axis ratios OARc and the measured results of PDDm and OARm in a water phantom were within 2%.Conclusion:When doing the Monte Carlo simulation to determine the parameters of an initial electron beam for a particular medical linac like BJ-6,modifying some parameters based on the particle dynamics calculation code would give some more reasonable and more acceptable results.
引用
收藏
页码:47 / 54 +66
页数:9
相关论文
共 7 条
  • [1] Monte Carlo Simulation-Based BEAMnrc Code of a 6 MV Photon Beam Produced by a Linear Accelerator (LINAC)
    Sapundani, R.
    Ekawati, R.
    Wibowo, K. M.
    ATOM INDONESIA, 2021, 47 (03) : 199 - 204
  • [2] Enhanced electron beam and X-ray beam therapy by applying nanoparticle heterojunctions: A Monte Carlo simulation
    Zhang, Chuhan
    Li, Xiaoyi
    Lu, Jingbin
    Li, Chengqian
    Wang, Yu
    Xu, Xu
    Yang, Xiangshan
    APPLIED RADIATION AND ISOTOPES, 2023, 199
  • [3] A multivariate approach to determine electron beam parameters for a Monte Carlo 6 MV Linac model: Statistical and machine learning methods
    Yang, Hye Jeong
    Kim, Tae Hoon
    Schaarschmidt, Thomas
    Park, Dong-Wook
    Kang, Seung Hee
    Chung, Hyun-Tai
    Suh, Tae Suk
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 93 : 38 - 45
  • [4] A CONVENIENT MULTIPLE SOURCE MODEL FOR VARIAN 2300C 6 MV-X BEAM BASED ON MONTE CARLO SIMULATED LINAC
    Lin, Hui
    Xu, Liangfeng
    Jing, Jia
    Li, Guoli
    Zhu, Yang
    Wu, Dong-Sheng
    Xu, Yuan-Ying
    Wu, Yican
    NUCLEAR TECHNOLOGY, 2009, 168 (03) : 706 - 712
  • [5] Prediction Model of Aluminized Coating Thicknesses Based on Monte Carlo Simulation by X-ray Fluorescence
    Li, Zhuoyue
    Wang, Cheng
    Ju, Haijuan
    Li, Xiangrong
    Qu, Yi
    Yu, Jiabo
    COATINGS, 2022, 12 (06)
  • [6] Monte Carlo simulation of x-ray scatter based on patient model from digital breast tomosynthesis
    Liu, Bob
    Wu, Tao
    Moore, Richard H.
    Kopans, Daniel B.
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [7] Numerical and Monte Carlo Simulation for Polychromatic L-Shell X-ray Fluorescence Computed Tomography Based on Pinhole Collimator with Sheet-Beam Geometry
    Yang, Shuang
    Jiang, Shanghai
    Shi, Shenghui
    Hu, Xinyu
    Zhao, Mingfu
    PHOTONICS, 2022, 9 (12)