Effect of coagulation pretreatment on the fouling of ultrafiltration membrane

被引:0
作者
DONG Bing-zhi
机构
关键词
drinking water treatment; ultrafiltration; coagulation; fouling;
D O I
暂无
中图分类号
X703 [废水的处理与利用];
学科分类号
083002 ;
摘要
The purpose of this study is to understand the effect and mechanism of preventing membrane fouling, by coagulation pretreatment, in terms of fractional component and molecular weight of natural organic matter (NOM). A relatively higher molecular weight (MW) of hydrophobic compounds was responsible for a rapid decline in the ultrafiltration flux. Coagulation could effectively remove the hydrophobic organics, resulting in the increase of flux. It was found that a lower MW of neutral hydrophilic compounds, which could remove inadequately by coagulation, was responsible for the slow declining flux. The fluxes in the filtration of coagulated water and supernatant water were compared and the results showed that a lower MW of neutral hydrophilic compounds remained in the supernatant water after coagulation could be rejected by a membrane, resulting in fouling. It was also found that the coagulated flocs could absorb neutral hydrophilic compounds effectively. Therefore, with the coagulated flocs formed on the membrane surface, the flux decline could be improved.
引用
收藏
页码:278 / 283
页数:6
相关论文
empty
未找到相关数据