Electrochimical determination of uric acid, xanthine and hypoxanthine by poly(xylitol) modified glassy carbon electrode

被引:1
作者
窦志宇 [1 ]
崔丽莉 [1 ]
何兴权 [1 ]
机构
[1] Department of Chemistry and Chemical Engineering, Changchun University of Science and Technology
关键词
xylitol; electropolymerization; uric acid; xanthine; hypoxanthine;
D O I
暂无
中图分类号
O657.1 [电化学分析法];
学科分类号
070302 ; 081704 ;
摘要
The novel covalently modified glassy carbon electrode with poly(xylitol) was prepared using an electropolymerization technique for the simultaneous determination of uric acid(UA), xanthine(XA) and hypoxanthine(HX). This new electrode presents an excellent electrocatalytic activity towards the oxidation of UA, XA and HX by cyclic voltammetry(CV) method. The oxidation peaks of the three compounds were well defined and had enhanced the peak currents. The separation potentials of the oxidation peak potentials for UA-XA and XA-HX were 380 and 370 mV in CV, respectively. Using differential pulse voltammetry(DPV) method, the calibration curves in the ranges of 5-55, 1.3-75.3 and 4-59 μmol/L were obtained for HX, XA and UA, respectively. The lowest detection limits(S/N=3) were 4.5, 0.75 and 3.75 μmol/L for HX, XA and UA, respectively. The practical application of the modified electrode was demonstrated by the determination of UA, XA, HX in human urine samples.
引用
收藏
页码:870 / 876
页数:7
相关论文
共 10 条
  • [1] Electrochemical sensor for simultaneous determination of uric acid, xanthine and hypoxanthine based on poly (bromocresol purple) modified glassy carbon electrode[J] . Yan Wang,Li-li Tong. Sensors & Actuators: B. Chemical . 2010 (1)
  • [2] Selective determination of L-dopa in the presence of uric acid and ascorbic acid at a gold nanoparticle self-assembled carbon nanotube-modified pyrolytic graphite electrode
    Hu, Guangzhi
    Chen, Long
    Guo, Yong
    Wang, Xiaolai
    Shao, Shijun
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (16) : 4711 - 4716
  • [3] Simultaneous determination of dopamine, ascorbic acid and uric acid at poly (Evans Blue) modified glassy carbon electrode[J] . Liqing Lin,Jinghua Chen,Hong Yao,Yuanzhong Chen,Yanjie Zheng,Xinhua Lin. Bioelectrochemistry . 2008 (1)
  • [4] Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method
    Dai, Xinhua
    Fang, Xiang
    Zhang, Chunmei
    Xu, Ruifeng
    Xu, Bei
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (02): : 287 - 295
  • [5] Indirect chemiluminescence detection for capillary zone electrophoresis of monoamines and catechol using luminol-K 3[Fe(CN) 6] system[J] . Yonggang Hu,Xinxin Li,Zhitao Pang. Journal of Chromatography A . 2005 (1)
  • [6] Fluorimetric determination of dopamine in pharmaceutical products and urine using ethylene diamine as the fluorigenic reagent[J] . Huai You Wang,Qiu Sha Hui,Li Xiao Xu,Ji Gang Jiang,Yue Sun. Analytica Chimica Acta . 2003 (1)
  • [7] A colorimetric 96-well microtiter plate assay for the determination of urate oxidase activity and its kinetic parameters
    Fraisse, L
    Bonnet, MC
    de Farcy, JP
    Agut, C
    Dersigny, D
    Bayol, A
    [J]. ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) : 173 - 179
  • [8] Determination of human plasma xanthine oxidase activity by high-performance liquid chromatography
    Yamamoto, T
    Moriwaki, Y
    Takahashi, S
    Tsutsumi, Z
    Yamakita, J
    Nasako, Y
    Hiroishi, K
    Higashino, K
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 681 (02): : 395 - 400
  • [9] XANTHINE ANALYSIS IN BIOLOGICAL-FLUIDS BY CAPILLARY ELECTROPHORESIS
    SHIHABI, ZK
    HINSDALE, ME
    BLEYER, AJ
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (01): : 163 - 169
  • [10] A Rapid Accurate Electrochemical Method for Serum Uric Acid[J] . George Park,R. N. Adams,Wesley R. White. Analytical Letters . 1972 (12)