Lens thickness assessment : anterior segment optical coherence tomography versus A-scan ultrasonography

被引:0
|
作者
Nikoo Hamzeh [1 ]
Sasan Moghimi [1 ,2 ]
Golshan Latifi [1 ]
Massood Mohammadi [1 ]
Nassim Khatibi [1 ]
Shan C.Lin [2 ]
机构
[1] Tehran University of Medical Science, Farabi Eye Hospital
[2] Koret Vision Center, San Francisco Medical School,University of California
关键词
lens thickness; A-scan ultrasonography; anterior segment-optical coherence tomography; biometry; cataract;
D O I
暂无
中图分类号
R776.1 [白内障];
学科分类号
100212 ;
摘要
AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography(AS-OCT)in comparison with A-scan ultrasonography(A-scan US).·METHODS: There were 218 adult subjects(218 eyes)aged 59.2 ±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System Ⅲ(LOCS Ⅲ). Lens thickness was measured by AS-OCT(Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA). The highest quality image was selected for each eye and lens thickness was calculated using Image J software. Lens thickness was also measured by A-scan US.·RESULTS: Interclass correlations showed a value of99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US(4.861 ±0.404 vs 4.866 ±0.351 mm, P =0.74).Lens thickness values obtained from the two instruments were highly correlated overall(Pearson correlation coefficient =0.81,P <0.001), and in all LOCS Ⅲ specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from-0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens(β=-0.29, P <0.001)· CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.
引用
收藏
页码:1151 / 1155
页数:5
相关论文
共 50 条
  • [1] Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography
    Hamzeh, Nikoo
    Moghimi, Sasan
    Latifi, Golshan
    Mohammadi, Massood
    Khatibi, Nassim
    Lin, Shan C.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (06) : 1151 - 1155
  • [2] Comparison of Lens Thickness Measurements Using the Anterior Segment Optical Coherence Tomography and A-scan Ultrasonography
    Zeng, Yangfa
    Liu, Yizhi
    Liu, Xing
    Chen, Chuying
    Xia, Yuanling
    Lu, Miaoling
    He, Mingguang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (01) : 290 - 294
  • [3] Quantitative assessment of lens opacities with anterior segment optical coherence tomography
    Wong, A. L.
    Leung, C. K-S
    Weinreb, R. N.
    Cheng, A. K. C.
    Cheung, C. Y. L.
    Lam, P. T-H
    Pang, C. P.
    Lam, D. S. C.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (01) : 61 - 65
  • [4] Anterior Chamber Depth and Lens Thickness Measurements in Pediatric Eyes: Ultrasound Biomicroscopy Versus Immersion A-Scan Ultrasonography
    Kolosky, Taylor
    Das, Urjita
    Panchal, Bhakti
    Byun, Sarah
    Dolgetta, Alexandra
    Levin, Moran R.
    Alexander, Janet L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (09): : 1346 - 1351
  • [5] Scleral Lens Clearance Assessment with Biomicroscopy and Anterior Segment Optical Coherence Tomography
    Yeung, Debby
    Sorbara, Luigina
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (01) : 13 - 20
  • [6] Assessment of anterior scleral thickness in myopes and emmetropes using anterior segment optical coherence tomography
    Li, Zhi-liang
    Xiong, Qi
    Cai, Shun-cheng
    Fu, Yue
    Li, Yu-ting
    Chen, Xiao-min
    Yang, Lin
    Ke, Min
    MOLECULAR VISION, 2024, 30 : 229 - 238
  • [7] Anterior segment optical coherence tomography of intraocular lens opacification
    Choudhry, Saurabh
    Goel, Neha
    Mehta, Aanchal
    Mahajan, Nidhi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (06) : 858 - 860
  • [8] Anterior segment optical coherence tomography in the assessment of postoperative intraocular lens optic changes
    Werner, Liliana
    Michelson, Jennifer
    Ollerton, Andrew
    Leishman, Lisa
    Bodnar, Zachary
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1077 - 1085
  • [9] Assessment of Anterior Segment Tumors with Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography in 200 Cases
    Bianciotto, Carlos
    Shields, Carol L.
    Guzman, Juan M.
    Romanelli-Gobbi, Massi
    Mazzuca, Douglas, Jr.
    Green, W. Ross
    Shields, Jerry A.
    OPHTHALMOLOGY, 2011, 118 (07) : 1297 - 1302
  • [10] Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography
    Nemeth, Gabor
    Vajas, Attila
    Tsorbatzoglou, Alexis
    Kolozsvari, Bence
    Modis, Laszlo, Jr.
    Berta, Andras
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 443 - 447