Posterior chamber phakic intraocular lens implantation for high myopia

被引:0
|
作者
Yan Ju [1 ]
Xiao-Wei Gao [1 ]
Bing Ren [1 ]
机构
[1] Department of Ophthalmology,No.474 Hospital of Chinese PLA
关键词
phakic intraocular lens; lens implantation; myopia;
D O I
暂无
中图分类号
R779.6 [眼外科手术学];
学科分类号
100212 ;
摘要
AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implantable Coliamer lens(ICL)placement by a single surgeon(Xiao-Wei Gao)to correct preoperative mean spherical equivalents between-9.00diopter(D)and-23.00D.Main outcome measures included uncorrected visual acuity(UCVA),refraction,best spectacle-corrected visual acuity(BSCVA),endothelial cell density(ECD),intraocular pressure(IOP),lens transparency,postoperative uveitis.Visante anterior segment optical coherence tomography(AS-OCT)was used to measure anterior chamber depth(ACD)and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months(range 3-12 months).Predictability of the manifest spherical equivalent(SE)refraction to within±1.OOD was achieved in 88%of eyes and±0.50D in 72.5%of eyes.The mean postoperative manifest SE refraction was-1.85±0.72D,with 96.34%of eyes maintaining or gaining≥1 line(s)of BSCVA.The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD.Of the 7 eyes(8.54%)with a mild transient increase in intraocular pressure(up to 30mmHg),none required a second surgical procedure or prolonged topical medication.There was no loss of lens transparency.Pigmented precipitates were observed in 5 eyes(6.09%).The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm,three months after surgery,the mean ACD was2.45±0.22mm.Anterior chamber depth showed astatistically significant reduction.One eye(1.22%)had ICL spontaneous rotation,81 eyes(98.78%)of the lens remained correctly centered.CONCLUSION:The implantation of ICL is an effective surgical option for the management of high myopia.But its long time effect and safety still need more time to prove.
引用
收藏
页码:831 / 835
页数:5
相关论文
共 50 条
  • [1] Posterior chamber phakic intraocular lens implantation for high myopia
    Shen, Y
    Du, CX
    Gu, YS
    Wang, J
    CHINESE MEDICAL JOURNAL, 2003, 116 (10) : 1523 - 1526
  • [2] Posterior chamber phakic intraocular lens implantation for high myopia
    沈晔
    杜持新
    顾扬顺
    王竞
    Chinese Medical Journal, 2003, (10)
  • [3] Posterior chamber phakic intraocular lens implantation for high myopia
    Ju, Yan
    Gao, Xiao-Wei
    Ren, Bing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (06) : 831 - 835
  • [4] Posterior chamber phakic intraocular lens implantation for high myopia
    沈晔
    杜持新
    顾扬顺
    王竞
    中华医学杂志(英文版), 2003, (10) : 83 - 86
  • [5] Phakic posterior chamber intraocular lens for high myopia
    Pineda-Fernández, A
    Jaramillo, J
    Vargas, J
    Jaramillo, M
    Jaramillo, J
    Galíndez, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11): : 2277 - 2283
  • [6] Implantation of a foldable Collamer lens as a posterior chamber phakic intraocular lens in myopia
    Roy, S
    Tritten, JJ
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (04) : 196 - 200
  • [7] Contrast sensitivity after posterior chamber phakic intraocular lens implantation for high myopia
    Jiménez-Alfaro, I
    Gómez-Tellería, G
    Bueno, JL
    Puy, P
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (06) : 641 - 645
  • [8] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Zhu, Yi
    Zhu, Haobin
    Jia, Yan
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2018, 18
  • [9] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Yi Zhu
    Haobin Zhu
    Yan Jia
    Jibo Zhou
    BMC Ophthalmology, 18
  • [10] Phakic posterior chamber lens implantation in children with high myopia
    Lesueur, LC
    Arne, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (12): : 1571 - 1575