Temporal pulsed x-ray response of CdZnTe:In detector

被引:0
|
作者
郭榕榕 [1 ,2 ]
徐亚东 [2 ]
查钢强 [2 ]
王涛 [2 ]
介万奇 [2 ]
机构
[1] School of Optoelectronic and Communication Engineering, Xiamen University of Technology
[2] State Key Laboratory of Solidification Processing, Northwestern Polytechnical University (NWPU)
基金
中国国家自然科学基金;
关键词
CdZnTe; ultrafast-pulsed x-rays; transient current; charge carrier;
D O I
暂无
中图分类号
TL81 [辐射探测技术和仪器仪表];
学科分类号
082704 ;
摘要
The temporal response of cadmium-zinc-telluride(CZT) crystals is evaluated at room temperature by using an ultrafast-pulsed x-ray source. The dynamics of carrier relaxation in a CZT single crystal is modeled at a microscopic level based on a multi-trapping effect. The effects of the irradiation flux and bias voltage on the amplitude and full width at half maximum(FWHM) of the transient currents are investigated. It is demonstrated that the temporal response process is affected by defect level occupation fraction. A fast photon current can be achieved under intense pulsed x-ray irradiation to be up to 2.78×10~9 photons mm-2·s-1. Meanwhile, it is found that high bias voltage could enhance carrier detrapping by suppressing the capture of structure defects and thus improve the temporal response of CZT detectors.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 50 条
  • [1] Temporal pulsed x-ray response of CdZnTe: In detector
    Guo, Rong-Rong
    Xu, Ya-Dong
    Zha, Gang-Qiang
    Wang, Tao
    Jie, Wan-Qi
    CHINESE PHYSICS B, 2018, 27 (12)
  • [2] The X-ray Radiation Response of CdZnTe Crystal Nuclear Detector
    Dai, X. Y.
    Meng, H.
    Zhang, Y. L.
    Tao, J.
    Xu, R.
    Zhang, J. J.
    Huang, J.
    Wang, L.
    Tang, K.
    Min, J. H.
    Wang, L. J.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY AND MANAGEMENT SCIENCE (ITMS 2015), 2015, 34 : 1296 - 1299
  • [3] The X-ray response of CdZnTe
    Owens, A
    Bavdaz, M
    Andersson, H
    Gagliardi, T
    Krumrey, M
    Nenonen, S
    Peacock, A
    Taylor, I
    Tröger, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3) : 242 - 250
  • [4] Progress in development on CdZnTe x-ray detector
    Zhou, Yongdong
    Zhou, Ning
    Zhang, Linhu
    Wang, Jin
    Wan, Aihua
    SEMICONDUCTOR PHOTODETECTORS III, 2006, 6119
  • [5] The analysis of X-ray response of CdZnTe detectors
    GangQiang Zha
    Hang Xiang
    Ting Liu
    YaDong Xu
    Tao Wang
    WanQi Jie
    Science China Technological Sciences, 2012, 55 : 2295 - 2299
  • [6] The analysis of X-ray response of CdZnTe detectors
    ZHA GangQiang
    Science China(Technological Sciences), 2012, (08) : 2295 - 2299
  • [7] The analysis of X-ray response of CdZnTe detectors
    Zha GangQiang
    Xiang Hang
    Liu Ting
    Xu YaDong
    Wang Tao
    Jie WanQi
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2012, 55 (08) : 2295 - 2299
  • [8] CdZnTe detector arrays for low-dose x-ray fluoroscopy
    Heanue, JA
    Pearson, DA
    Melen, RE
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 114 - 121
  • [9] Detective quantum efficiency of flat panel CdZnTe x-ray detector
    Khym, GL
    Kim, KH
    Park, YJ
    Yang, HJ
    Kim, SU
    Jung, TR
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 45 : S893 - S897
  • [10] On the correlation between crystal morphology and X-ray performance of a CdZnTe detector
    Bavdaz, M
    Peacock, A
    Nenonen, S
    Jantunen, MA
    Gagliardi, T
    Tuomi, T
    Hjelt, KT
    Juvonen, M
    Rantamaki, R
    Kraft, S
    Wedowski, M
    Scholze, F
    Ulm, G
    McNally, PJ
    Curley, J
    Danilewsky, AN
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 322 - 332