Study of Preionization XeCl Excimer Laser and Ultraviolet Spectrum Characteristic

被引:0
|
作者
任韧 [1 ]
陈长乐 [2 ]
徐进 [3 ]
任大男 [4 ]
宋宙模 [2 ]
机构
[1] Department of Physics & Institue of Biomedical Engineering, Xi'an Jiaotong University, Xi'an 710049, China Department of Physics, Northwestern Poly-technical University, Xi'an 710072, China
[2] Department of Physics, Northwestern Poly-technical University, Xi'an 710072, China
[3] Department of Physics & Institue of Biomedical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
[4] Department of Mathematics, Northwest University, Xi'an 710069, China
基金
美国国家科学基金会;
关键词
UV spectroscopy; plasma; short duration; nanosecond discharge;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The pumped system of the XeC1 excimer laser has been designed and applied to analyze UV XeCl laser spectroscopy characteristics. Under the proportion of mixed gas of HCl:Xe:He=0.1%:1%:98.9%, excimer laser light was generated by stable glow discharge process. The laser spectrum, pulse duration, and laser power properties were obtained. The result shows that this XeCl excimer laser exhibits unique spectral properties, with two peaks between 307.7 nm and 308.5 nm at high pressure with a pumped power of 1.3959 MW/cm;. The transition relies on the strongest transitions between B-X and C-X. The maximum-intensity transition of spectroscopy is B to X energy levels. The laser parameters are as follows: minimal duration of 15.42 ns, a repetition rate from 0.5 Hz to 5 Hz, single pulse stable power of 400 mJ, and beam divergence angle of 3 mrad. The laser can be used to study UV spectroscopy, laser ablation sampling and sputtered pinnate form.
引用
收藏
页码:561 / 564
页数:4
相关论文
共 50 条
  • [31] COMPACT AND RELIABLE DISCHARGE-PUMPED XECL LASER WITH AUTOMATIC PREIONIZATION
    HIRAMATSU, M
    GOTO, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (04): : 534 - 538
  • [32] Spectrum characteristic study of sodium - ethane excimer pairs
    Hu, Shu
    Gai, Baodong
    Wang, Pengyuan
    Li, Hui
    Tan, Yannan
    Liu, Jinbo
    Guo, Jingwei
    XXI INTERNATIONAL SYMPOSIUM ON HIGH POWER LASER SYSTEMS AND APPLICATIONS 2016, 2017, 10254
  • [33] HF CHEMICAL-LASER INITIATED BY AN EXCIMER XECL LASER
    BORISOV, VM
    GORDON, EB
    MATYUSHENKO, VI
    SIZOV, VD
    KHRISTOFOROV, OB
    KVANTOVAYA ELEKTRONIKA, 1982, 9 (02): : 434 - 436
  • [34] MULTIPHOTON IONIZATION AND FRAGMENTATION STUDY OF ACETONE AT XECL EXCIMER LASER-RADIATION
    LIU, H
    LI, S
    HAN, J
    GUAN, Y
    WU, C
    CHEMICAL PHYSICS, 1987, 118 (02) : 285 - 287
  • [35] XECL EXCIMER LASER WITH A CONTINUOUSLY TUNABLE OUTPUT PULSEWIDTH
    DILAZZARO, P
    FLORA, F
    GERARDINO, A
    LETARDI, T
    OPTICS COMMUNICATIONS, 1993, 95 (4-6) : 336 - 344
  • [36] XeCl theoretical model for computer controlled excimer laser
    Pokora, L.
    Ujda, Z.
    OPTICA APPLICATA, 1992, 22 (3-4) : 145 - 154
  • [37] Effect of inductive-plasma UV preionization on the parameters of XeCl laser radiation
    A. I. Fedorov
    Technical Physics Letters, 2007, 33 : 678 - 681
  • [38] DETERMINATION OF THE MINIMUM X-RAY FLUX FOR EFFECTIVE PREIONIZATION OF AN XECL LASER
    TALLMAN, CR
    BIGIO, IJ
    APPLIED PHYSICS LETTERS, 1983, 42 (02) : 149 - 151
  • [39] Photoablation and microstructuring of polyestercarbonates and their blends with a XeCl excimer laser
    Kunz, T
    Stebani, J
    Ihlemann, J
    Wokaun, A
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 67 (03): : 347 - 352
  • [40] FOLDED LONG PULSE XeCl EXCIMER LASER.
    Cao, Hongru
    Chen, Yongrong
    Che, Mingyu
    Hu, Xuejin
    Guangxue Xuebao/Acta Optica Sinica, 1987, 7 (05): : 410 - 414