Study of Preionization XeCl Excimer Laser and Ultraviolet Spectrum Characteristic

被引:0
|
作者
任韧 [1 ]
陈长乐 [2 ]
徐进 [3 ]
任大男 [4 ]
宋宙模 [2 ]
机构
[1] Department of Physics & Institue of Biomedical Engineering, Xi'an Jiaotong University, Xi'an 710049, China Department of Physics, Northwestern Poly-technical University, Xi'an 710072, China
[2] Department of Physics, Northwestern Poly-technical University, Xi'an 710072, China
[3] Department of Physics & Institue of Biomedical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
[4] Department of Mathematics, Northwest University, Xi'an 710069, China
基金
美国国家科学基金会;
关键词
UV spectroscopy; plasma; short duration; nanosecond discharge;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The pumped system of the XeC1 excimer laser has been designed and applied to analyze UV XeCl laser spectroscopy characteristics. Under the proportion of mixed gas of HCl:Xe:He=0.1%:1%:98.9%, excimer laser light was generated by stable glow discharge process. The laser spectrum, pulse duration, and laser power properties were obtained. The result shows that this XeCl excimer laser exhibits unique spectral properties, with two peaks between 307.7 nm and 308.5 nm at high pressure with a pumped power of 1.3959 MW/cm;. The transition relies on the strongest transitions between B-X and C-X. The maximum-intensity transition of spectroscopy is B to X energy levels. The laser parameters are as follows: minimal duration of 15.42 ns, a repetition rate from 0.5 Hz to 5 Hz, single pulse stable power of 400 mJ, and beam divergence angle of 3 mrad. The laser can be used to study UV spectroscopy, laser ablation sampling and sputtered pinnate form.
引用
收藏
页码:561 / 564
页数:4
相关论文
共 50 条
  • [21] THE XECL LASER SPECTRUM
    ADAMOVICH, VA
    BARANOV, VY
    LIKHANSKII, VV
    MALYUTA, DD
    NAPARTOVICH, AP
    STRELTSOV, AP
    KVANTOVAYA ELEKTRONIKA, 1986, 13 (11): : 2216 - 2220
  • [22] Preionization of XeF excimer laser by 248 nm laser beam
    Maulhardt, G.
    Schmidt, K.
    Bartuch, U.
    Vioel, W.
    LASER PHYSICS LETTERS, 2007, 4 (01) : 33 - 37
  • [23] MUTAGENICITY AND THE XECL EXCIMER LASER - A RELATIONSHIP OF CONSEQUENCE
    FELD, MS
    KRAMER, JR
    AMERICAN HEART JOURNAL, 1991, 122 (06) : 1803 - 1805
  • [24] OUTPUT CHARACTERISTICS OF AN EXCIMER LASER WITH DELAYED DOUBLE PREIONIZATION
    LUCHES, A
    NASSISI, V
    PERRONE, MR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (08): : 1015 - 1018
  • [25] MULTIPHOTON IONIZATION AND FRAGMENTATION STUDY OF ACETONE AT XeCl EXCIMER LASER RADIATION
    Liu Houxiang
    Li Shutao
    Han Jingcheng
    Guan Yifu
    Zhu Rong
    Wu Cunkai
    ACTA PHYSICO-CHIMICA SINICA, 1988, 4 (02) : 182 - 186
  • [26] L-BAND MICROWAVE PUMPED XECL LASER WITHOUT PREIONIZATION
    KLINGENBERG, HH
    GEKAT, F
    SPINDLER, G
    APPLIED OPTICS, 1990, 29 (09): : 1246 - 1248
  • [27] The Development and Progress of XeCl Excimer Laser System
    Zhang, Yongsheng
    Ma, Lianying
    Wang, Dahui
    Zhao, Xueqing
    Zhu, Yongxiang
    Hu, Yun
    Qian, Hang
    THIRD INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER, 2015, 9543
  • [28] AN EFFICIENT HIGH-PRESSURE XECL DISCHARGE LASER WITH UV PREIONIZATION
    CHALTAKOV, IV
    TOMOV, IV
    CHRISTOV, CG
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1986, 19 (12): : 1034 - 1037
  • [29] Transmyocardial laser revascularization using a XeCl excimer laser: Initial results of a randomized study
    Huikeshoven, M
    Beek, JF
    van der Sloot, JAP
    van der Meulen, J
    Tukkie, R
    LASERS IN SURGERY AND MEDICINE, 2002, : 51 - 51
  • [30] Theoretical and experimental investigations of the 1 kW XeCl laser with UV preionization
    Borisov, VM
    Khristoforov, OB
    Kirykhin, YB
    Vinokhodov, AY
    Demin, AI
    Demyanov, AV
    GAS AND CHEMICAL LASERS AND APPLICATIONS II, 1997, 2987 : 94 - 104