An integrated microfluidic chip-mass spectrometry system for rapid antimicrobial resistance analysis of bacteria producing β-lactamases

被引:1
|
作者
Zhaochen Su [1 ]
Wanting Hu [1 ]
Lizhen Ye [1 ]
Dan Gao [1 ]
Jin-Ming Lin [2 ]
机构
[1] State Key Laboratory of Chemical Oncogenomics, Key Laboratory of Chemical Biology, Tsinghua Shenzhen International Graduate School, Tsinghua University
[2] Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology (Ministry of Education), Tsinghua University
关键词
D O I
暂无
中图分类号
R446.5 [微生物学检验]; TH843 [质谱仪];
学科分类号
摘要
Bacteria producing β-lactamases have become a major issue in the global public health field. To restrain the development of drug resistance and reduce the abuse of antibiotics, it is very important to rapidly identify bacteria producing β-lactamases and put forward a reasonable treatment plan. Here, an integrated microfluidic chip-mass spectrometry system was proposed for rapid screening of β-lactamaseproducing bacteria and optimization of β-lactamase inhibitor dosing concentration. The concentration gradient generator followed by an array of bacterial culture chambers, as well as micro-solid-phase extraction columns was designed for sample pretreatment before mass analysis. By using the combination system, the process of the hydrolysis of antibiotics by β-lactamase-producing bacteria could be analyzed. To validate the feasibility, four antibiotics and two antibiotic inhibitors were investigated using three strains including negative control, SHV-1 and TEM-1 strains. SHV-1 and TEM-1 strains were successfully distinguished as the β-lactamase producing strains. And the acquired optimal concentrations ofβ-lactamase inhibitors were in accordance with the results by that obtained from the traditional microdilution broth method. The total analysis time only needed around 2 h, which was faster than conventional methods that require a few days. The technique presented herein provides an easy and rapid protocol forβ-lactamase resistance related studies, which is important for the inhibition of antimicrobial resistance development and the reduction of antibiotics abuse.
引用
收藏
页码:354 / 357
页数:4
相关论文
共 50 条
  • [31] Towards a modular microfluidic system for proteome analysis by mass spectrometry
    Figeys, D
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 457 - 462
  • [32] P10 Rapid capture of uropathogenic bacteria and on-chip determination of antimicrobial resistance
    Dsouza, Andrea
    Hand, Rachel
    Constantinidou, Chrystala
    Arvanitis, Theodoros N.
    Haddleton, David M.
    Charmet, Jerome
    JAC-ANTIMICROBIAL RESISTANCE, 2022, 4
  • [33] Fabrication of a polystyrene microfluidic chip coupled to electrospray ionization mass spectrometry for protein analysis
    Hu, Xianqiao
    Dong, Yuanyuan
    He, Qiaohong
    Chen, Hengwu
    Zhu, Zhiwei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 : 96 - 103
  • [34] A multifunctional microfluidic droplet-array chip for analysis by electrospray ionization mass spectrometry
    Su, Yuan
    Zhu, Ying
    Fang, Qun
    LAB ON A CHIP, 2013, 13 (10) : 1876 - 1882
  • [35] AN INTEGRATED MICROFLUIDIC SYSTEM FOR RAPID ISOLATION AND DETECTION OF LIVE BACTERIA IN PERIPROSTHETIC JOINT INFECTIONS
    Chang, Wen-Hsin
    Wang, Chih-Hung
    Yang, Sung-Yi
    Lin, Yi-Cheng
    Wu, Jiunn-Jong
    Lee, Mel S.
    Lee, Gwo-Bin
    2014 IEEE 27TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2014, : 5 - 8
  • [36] Analysis of intact bacteria using rapid evaporative ionisation mass spectrometry
    Strittmatter, Nicole
    Jones, Emrys A.
    Veselkov, Kirill A.
    Rebec, Monica
    Bundy, Jacob G.
    Takats, Zoltan
    CHEMICAL COMMUNICATIONS, 2013, 49 (55) : 6188 - 6190
  • [37] Engineering an integrated system with a high pressure polymeric microfluidic chip coupled to liquid chromatography-mass spectrometry (LC-MS) for the analysis of abused drugs
    Chen, Pin-Chuan
    Zhang, Wei-Zhe
    Chen, Wei-Ru
    Jair, Yung-Cheng
    Wu, Yi-Hsin
    Liu, Yi-Hsin
    Chen, Pei-Zhen
    Chen, Lian-Yu
    Chen, Pai-Shan
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 350
  • [38] Machine Learning Assisted MALDI Mass Spectrometry for Rapid Antimicrobial Resistance Prediction in Clinicals
    Gao, Weibo
    Li, Hang
    Yang, Jingxian
    Zhang, Jinming
    Fu, Rongxin
    Peng, Jiaxi
    Hu, Yechen
    Liu, Yitong
    Wang, Yingshi
    Li, Shuang
    Zhang, Shuailong
    ANALYTICAL CHEMISTRY, 2024, 96 (33) : 13398 - 13409
  • [39] On-line multi-residue analysis of fluoroquinolones and amantadine based on an integrated microfluidic chip coupled to triple quadrupole mass spectrometry
    Tang, Minmin
    Zhao, Yaju
    Chen, Jing
    Xu, Danke
    ANALYTICAL METHODS, 2020, 12 (44) : 5322 - 5331
  • [40] Analysis of recombinant adenoviruses using an integrated microfluidic chip-based system
    McCaman, MT
    Murakami, P
    Pungor, E
    Hahnenberger, KM
    Hancock, WS
    ANALYTICAL BIOCHEMISTRY, 2001, 291 (02) : 262 - 268