Determination of VOCs in groundwater at an industrial contamination site using a homemade low-density polyethylene passive difusion sampler

被引:1
作者
Xu Ma
Zhiqiang Tan
Long Pang
Jingfu Liu
机构
[1] StateKeyLaboratoryofEnvironmentalChemistryandEcotoxicology,ResearchCenterforEco-EnvironmentalSciencesChineseAcademyofSciences
关键词
equilibration time; ground water; passive sampling; polyethylene difusion bag; volatile organic compounds;
D O I
暂无
中图分类号
X832 [水质监测];
学科分类号
0804 ; 082803 ;
摘要
A home-made inexpensive passive difusion bag(PDB)sampler,prepared by filling deionized water in low-density polyethylene(LDPE)tubes,was evaluated for volatile organic compounds(VOC)sampling in groundwater at industrial contamination sites.Impacts of environmentally relevant conditions on the sampling equilibration time and partitioning of VOCs between the sampler and the water sample were investigated.Sample salinity,agitation and temperature can influence the equilibration time,but generally sampling equilibration was obtained in 14 days under real field sampling of VOCs in groundwater.Both laboratory study and field testing in a contaminated site showed that the VOC concentrations in the developed sampler were equal to those in the water samples at equilibrium.Coupled with a purge and trap concentrator-gas chromatograph-mass spectrometer(P&T-GC-MS),the developed PDB sampler provided a low-cost sampling device for routine monitoring of VOCs in groundwater in wells,with LODs in the range of2.9–10μg/L.The proposed PDB was applied to determine VOCs in groundwater at an industrial contamination site,and the present results agreed well with those determined using conventional pump-and-sample monitoring.All the studied 13 VOCs were tested in the four wells in the industrial contamination sites,with their concentrations in the range of 12–73660μg/L.In addition,while benzene and toluene were heavily contaminated up to a maximum concentration of 74000μg/L and 6000μg/L,respectively,1,2,3-trichlorobenzene and bromobenzene had relatively low contamination levels(below 25μg/L).
引用
收藏
页码:2338 / 2343
页数:6
相关论文
共 5 条
[1]   Passive Samplers for Monitoring VOCs in Groundwater and the Prospects Related to Mass Flux Measurements [J].
Verreydt, Goedele ;
Bronders, Jan ;
Van Keer, Ilse ;
Diels, Ludo ;
Vanderauwera, Paul .
GROUND WATER MONITORING AND REMEDIATION, 2010, 30 (02) :114-126
[2]  
Laboratory Comparison of Polyethylene and Dialysis Membrane Diffusion Samplers[J] . Theodore A.Ehlke,Thomas E.Imbrigiotta,Jeffrey M.Dale.Ground Water Monitoring & Remediation . 2007 (1)
[3]  
Diffusion Samplers as an Inexpensive Approach to Monitoring VOCs in Ground Water[J] . Don A.Vroblesky,W. ThomasHyde.Ground Water Monitoring & Remediation . 2007 (3)
[4]  
Passive diffusion ground water samplers at a site with heterogeneous hydrostratigraphy: Pilot study results[J] . CraigE. Divine,LauraL. Madsen,ScottD. Andrews,Theresa Santangelo‐Dreiling.Ground Water Monitoring & Remediation . 2005 (1)
[5]  
Equilibration times, compound selectivity, and stability of diffusion samplers for collection of ground-water VOC concentrations[J] . Don A Vroblesky,Ted R Campbell.Advances in Environmental Research . 2001 (1)