摘要
This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 13 条
[1]   螺旋管式相变蓄热过程的数值模拟与系统优化 [J].
朱家玲 ;
李慧 ;
张伟 .
天津大学学报, 2012, 45 (10) :875-880
[2]   太阳能-地源热泵系统的交替运行特性(英文) [J].
杨卫波 ;
陈振乾 ;
施明恒 .
Journal of Southeast University(English Edition), 2010, 26 (02) :327-332
[3]   Long term operation of a solar assisted ground coupled heat pump system for space heating and domestic hot water [J].
Chen Xi ;
Lu Lin ;
Yang Hongxing .
ENERGY AND BUILDINGS, 2011, 43 (08) :1835-1844
[4]   Experimental studies on a ground coupled heat pump with solar thermal collectors for space heating [J].
Chen Xi ;
Yang Hongxing ;
Lu Lin ;
Wang Jinggang ;
Liu Wei .
ENERGY, 2011, 36 (08) :5292-5300
[5]   Energy analysis of a solar-ground source heat pump system with vertical closed-loop for heating applications [J].
Bakirci, Kadir ;
Ozyurt, Omer ;
Comakli, Kemal ;
Comakli, Omer .
ENERGY, 2011, 36 (05) :3224-3232
[6]  
A new model and analytical solutions for borehole and pile ground heat exchangers[J] . Yi Man,Hongxing Yang,Nairen Diao,Junhong Liu,Zhaohong Fang. International Journal of Heat and Mass Transfer . 2010 (13)
[7]   Experimental study of a solar-assisted ground-coupled heat pump system with solar seasonal thermal storage in severe cold areas [J].
Wang, Xiao ;
Zheng, Maoyu ;
Zhang, Wenyong ;
Zhang, Shu ;
Yang, Tao .
ENERGY AND BUILDINGS, 2010, 42 (11) :2104-2110
[8]  
Thermal performance of borehole heat exchanger under groundwater flow: A case study from Baoding[J] . Huajun Wang,Chengying Qi,Hongpu Du,Jihao Gu. Energy & Buildings . 2009 (12)
[9]  
Finite line-source model for borehole heat exchangers: effect of vertical temperature variations[J] . Tatyana V. Bandos,álvaro Montero,Esther Fernández,Juan Luis G. Santander,José María Isidro,Jezabel Pérez,Pedro J. Fernández de Córdoba,Javier F. Urchueguía. Geothermics . 2009 (2)
[10]   Fast fluid and ground temperature computation for geothermal ground-loop heat exchanger systems [J].
Marcotte, Denis ;
Pasquier, Philippe .
GEOTHERMICS, 2008, 37 (06) :651-665