Fabrication of the beam splitters for soft X-ray laser application

被引:0
|
作者
WANG Zhanshan1
2. National Synchrotron Radiation Laboratory
3. Institute of High Energy Physics
机构
关键词
soft X-ray; beam splitter; multilayer; interference;
D O I
暂无
中图分类号
TN249 [激光的应用];
学科分类号
摘要
The soft X-ray interferometry is completed by the Mach-Zehnder interferometer using a soft X-ray laser, and it is also an important method to measure the electron densities of a laser-produced plasma near the critical surface. It is apparently demonstrated in this paper that the incident angle of each optical element in the soft X-ray Mach- Zehnder interferometer should be near normal incidence based on the polarized characteristics of the soft X-ray mul-tilayers, and the product of reflectivity and transmission of the beam splitter should be taken as a standard of design according to the structure of the soft X-ray Mach-Zehnder interferometer. The beam splitters used in the soft X-ray interferometry at 13.9 nm are fabricated using the ion beam sputtering. The figure error of the beam splitter has reached the nanometer magnitude, in which the product of reflectiv-ity and transmission of the beam splitter is more than 1.6%.
引用
收藏
页码:1930 / 1933
页数:4
相关论文
共 50 条
  • [1] Fabrication of the beam splitters for soft X-ray laser application
    Wang, ZS
    Wu, YG
    Tang, WX
    Qin, SJ
    Chen, LY
    Xu, XD
    Hong, YL
    Fu, SJ
    Zhu, J
    Cui, MQ
    CHINESE SCIENCE BULLETIN, 2003, 48 (18): : 1930 - 1933
  • [2] Soft X-ray multilayer beam splitters
    Haga, T
    Tinone, MCK
    Shimada, M
    Ohkubo, T
    Ozawa, A
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 690 - 692
  • [3] Soft X-ray multilayer beam splitters
    Haga, Tsuneyuki
    Tinone, Marcia C. K.
    Shimada, Masaru
    Ohkubo, Takashi
    Ozawa, Akira
    Journal of Synchrotron Radiation, 1998, 5 (03): : 690 - 692
  • [4] Fabrication of soft X-ray beam splitters for use in the wavelength region around 13 nm
    Takenaka, H
    Ichimaru, S
    Haga, T
    Ohchi, T
    Ito, H
    Muramatsu, Y
    Guilikson, EM
    Perera, RCC
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 251 - 254
  • [5] Soft x-ray multilayer beamsplitter for x-ray laser application
    Tang, H
    Yi, K
    Fan, Z
    Gu, Y
    Wang, S
    X-RAY LASERS 1998, 1999, 159 : 613 - 614
  • [6] Generation and application of the soft X-ray laser beam based on capillary discharge
    Frolov, Oleksandr
    Kolacek, Karel
    Straus, Jaroslav
    Schmidt, Jiri
    Prukner, Vaclav
    Shukurov, Andrey
    15TH INTERNATIONAL CONGRESS ON PLASMA PHYSICS (ICPP2010) & 13TH LATIN AMERICAN WORKSHOP ON PLASMA PHYSICS (LAWPP2010), 2014, 511
  • [7] Bessel spatial profile of a soft x-ray laser beam
    Tissandier, F.
    Sebban, S.
    Ribiere, M.
    Gautier, J.
    Zeitoun, Ph.
    Lambert, G.
    Goddet, J. -Ph.
    Burgy, F.
    Valentin, C.
    Rousse, A.
    Nejdl, J.
    Mocek, T.
    Maynard, G.
    APPLIED PHYSICS LETTERS, 2010, 97 (23)
  • [8] Absolute calibration of a soft X-ray spectrograph for X-ray laser research using white beam
    Fujikawa, C
    Kawachi, T
    Ando, K
    Yamaguchi, N
    Hara, T
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 756 - 758
  • [9] Formation of sub-μm x-ray beam from tabletop soft x-ray laser
    Ohchi, T
    Yamaguchi, N
    Fujikawa, C
    Hara, T
    X-RAY LASERS 1998, 1999, 159 : 683 - 686
  • [10] Fabrication of an X-Ray Mirror Used in a Soft X-Ray Microscope
    Chon, K. S.
    Namba, Y.
    Yoon, K. H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1644 - +