Anodic voltammetric determination of gemifloxacin using screen-printed carbon electrode

被引:0
|
作者
Abd-Elgawad Radi [1 ]
Amira Khafagy [1 ]
Amira El-shobaky [1 ]
Hatem El-mezayen [2 ]
机构
[1] Department of Chemistry,Faculty of Science,Dumyat University
[2] Department of Chemistry,Faculty of Science,Helwan University
关键词
Screen-printed carbon electrode; Voltammetry; Gemifloxacin; Pharmaceutical analysis;
D O I
暂无
中图分类号
R917 [药物分析];
学科分类号
100704 ;
摘要
The electrochemical oxidation behavior and voltammetric assay of gemifloxacin were investigated using differential-pulse and cyclic voltammetry on a screen-printed carbon electrode.The effects of pH,scan rates,and concentration of the drug on the anodic peak current were studied.Voltammograms of gemifloxacin in Tris-HCl buffer(pH 7.0) exhibited a well-defined single oxidation peak.A differential-pulse voltammetric procedure for the quantitation of gemifloxacin has been developed and suitably validated with respect to linearity,limits of detection and quantification,accuracy,precision,specificity,and robustness.The calibration was linear from 0.5 to 10.0 μM,and the limits of detection and quantification were 0.15 and 5.0 μM.Recoveries ranging from 96.26% to 103.64% were obtained.The method was successfully applied to the determination of gemifloxacin in pharmaceutical tablets without any pre-treatment.Excipients present in the tablets did not interfere in the assay.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [31] Porous screen-printed carbon electrode
    Niu, Xiangheng
    Chen, Chen
    Zhao, Hongli
    Tang, Jie
    Li, Yuxiu
    Lan, Minbo
    ELECTROCHEMISTRY COMMUNICATIONS, 2012, 22 : 170 - 173
  • [32] Anodic stripping voltammetry with a heated mercury film on a screen-printed carbon electrode
    Jasinski, M
    Gründler, P
    Flechsig, GU
    Wang, J
    ELECTROANALYSIS, 2001, 13 (01) : 34 - 36
  • [33] Voltammetric Determination of Active Pharmaceutical Ingredients Using Screen-Printed Electrodes
    Clares, Paula
    Perez-Rafols, Clara
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    CHEMOSENSORS, 2022, 10 (03)
  • [34] Ex-situ Antimony Screen-printed Carbon Electrode for Voltammetric Determination of Ni(II)-ions in Wastewater
    Barcelo, Cristian
    Serrano, Nuria
    Arino, Cristina
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    ELECTROANALYSIS, 2016, 28 (03) : 640 - 644
  • [35] Electrochemically activated multi-walled carbon nanotubes modified screen-printed electrode for voltammetric determination of sulfentrazone
    Silva, Raquel de Oliveira
    da Silva, Erica Amorim
    Fiorucci, Antonio Rogerio
    Ferreira, Valdir Souza
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 835 : 220 - 226
  • [36] Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples
    Honeychurch, Kevin C.
    SENSORS, 2022, 22 (12)
  • [37] Simultaneous Voltammetric Determination of Acetaminophen and Caffeine at a Graphite and Polyurethane Screen-Printed Composite Electrode
    Saciloto, Thalita R.
    Cervini, Priscila
    Cavalheiro, Eder T. G.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (09) : 1461 - 1468
  • [38] Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
    Puy-Llovera, Jaume
    Perez-Rafols, Clara
    Serrano, Nutiria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    TALANTA, 2017, 175 : 501 - 506
  • [39] Determination of Copper(II) Through Anodic Stripping Voltammetry in Tartrate Buffer Using an Antimony Film Screen-printed Carbon Electrode
    Bobrowski, Andrzej
    Maczuga, Mariola
    Krolicka, Agnieszka
    Konstanteli, Evangelia
    Sakellaropoulou, Chrysavgi
    Economou, Anastasios
    ANALYTICAL LETTERS, 2017, 50 (18) : 2920 - 2936
  • [40] Screen-Printed Voltammetric Biosensors for the Determination of Copper in Wine
    Norocel, Liliana
    Gutt, Gheorghe
    SENSORS, 2019, 19 (21)