Measurement Error of Refractive Index for Spectacle Lens

被引:0
|
作者
叶佳意 [1 ,2 ]
蒋伟忠 [1 ,2 ]
唐玲玲 [1 ]
机构
[1] Research Institute ,Donghua University
[2] College of Materials Science and Engineering,Donghua University
关键词
spectacles lens; refractive index; measurement error; V prism refractometer;
D O I
10.19884/j.1672-5220.2017.04.023
中图分类号
TS959.6 [眼镜及其制造];
学科分类号
0822 ;
摘要
As an important optical constant of optical properties for spectacle lens,the refractive index measurement is studied using V prism refractometer. In the experiment,according to various factors inducing measurement error,the experimental results are analyzed,which include right angle deviation,contact liquid,curvature,and focusing accuracy. The study results show that focusing accuracy is the most important factor of influence for measurement,consists of contact liquid wettability,sample shape,and effective width of light transmission. In addition,the refractive index measurement is less affected by angle deviation of sample and the refractive index deviation of contact liquid. On the basis of the experimental data analysis,it is possible to relax the deviation of right angle of the sample to 1’ or 2’.
引用
收藏
页码:613 / 616
页数:4
相关论文
共 50 条
  • [41] Refractometer with broad refractive index measurement range
    Wan, Jing
    Lu, Yu
    Lu, Zhian
    Dou, Weiqi
    Wang, Cheng
    Jiang, Guirong
    SIXTH INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONIC ENGINEERING (ICOPEN 2018), 2018, 10827
  • [42] Measurement of refractive index of photopolymer for holographic gratings
    Watanabe, Eriko
    Mizuno, Jun
    Fujikawa, Chiemi
    Kodate, Kashiko
    PRACTICAL HOLOGRAPHY XXI: MATERIALS AND APPLICATIONS, 2007, 6488
  • [43] Measurement of refractive index of luminescent photoelastic coating
    Hua Shi-Qun
    Luo Yin
    ACTA PHYSICA SINICA, 2013, 62 (05)
  • [44] Surface Roughness and Refractive Index Changes in Contact Lens Induced by Lens Care Systems
    Lira, Madalena
    Franco, Sandra
    Benito Vazquez-Dorrio, Jose
    Real Oliveira, M. Elisabete C. D.
    Costa, Manuel F. M.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (03): : 140 - 147
  • [45] Changes in the refractive index of lens fibre membranes during maturation - impact on lens transparency
    Michael, R
    van Marle, J
    Vrensen, GFJM
    van den Berg, TJTP
    EXPERIMENTAL EYE RESEARCH, 2003, 77 (01) : 93 - 99
  • [46] Equivalent Refractive Index of the Human Lens upon Accommodative Response
    Hermans, Erik A.
    Dubbelman, Michiel
    Van der Heijde, Rob
    Heethaar, Rob M.
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (12) : 1179 - 1184
  • [47] The assessment of automated measures of hydrogel contact lens refractive index
    Nichols, JJ
    Berntsen, DA
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (06) : 517 - 525
  • [48] Analysis of method of determination of refractive index and Abbe number of lens
    Smejkal, Michal
    Smejkal, Filip
    Miks, Antonin
    Novak, Jiri
    Novak, Pavel
    Pokorny, Petr
    OPTICAL FABRICATION, TESTING, AND METROLOGY VI, 2018, 10692
  • [49] Interference measurement of refractive index in blanks for gradient-index optics
    Gerasimova, LA
    OPTICAL ENGINEERING, 1996, 35 (12) : 3562 - 3567
  • [50] Measurement of the refractive index of a transparent film using interferometry
    Lee, H. J.
    Han, S-H
    An, S. Y.
    Song, W.
    Shin, O.
    Kim, S-B
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION XI, 2019, 11056