Image quality of cone beam CT on respiratory motion

被引:0
|
作者
ZHANG Ke1 LI Minghui1 DAI Jianrong1
机构
基金
中国国家自然科学基金;
关键词
Respiratory motion; Cone beam CT; Image quality;
D O I
10.13538/j.1001-8042/nst.22.111-117
中图分类号
TP391.41 [];
学科分类号
080203 ;
摘要
In this study,the influence of respiratory motion on Cone Beam CT (CBCT) image quality was investigated by a motion simulating platform,an image quality phantom,and a kV X-ray CBCT.A total of 21 motion states in the superior-inferior direction and the anterior-posterior direction,separately or together,was simulated by considering different respiration amplitudes,periods and hysteresis.The influence of motion on CBCT image quality was evaluated with the quality indexes of low contrast visibility,geometric accuracy,spatial resolution and uniformity of CT values.The results showed that the quality indexes were affected by the motion more prominently in AP direction than in SI direction,and the image quality was affected by the respiration amplitude more prominently than the respiration period and the hysteresis.The CBCT image quality and its characteristics influenced by the respiration motion,and may be exploited in finding solutions.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [41] Prediction of detectability of the mandibular canal by quantitative image quality evaluation using cone beam CT
    Takeshita, Yohei
    Shimizu, Mayumi
    Jasa, Gainer R.
    Weerawanich, Warangkana
    Okamura, Kazutoshi
    Yoshida, Shoko
    Tokumori, Kenji
    Asaumi, Junichi
    Yoshiura, Kazunori
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (04)
  • [42] Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities
    Lechuga, Lawrence
    Weidlich, Georg A.
    CUREUS, 2016, 8 (09):
  • [43] A Validation Framework for Head-Motion Artifacts in Dental Cone-Beam CT
    Ens, S.
    Bruder, R.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 658 - 661
  • [44] Image quality improvement in megavoltage cone beam CT using an imaging beam line and a sintered pixelated array system
    Breitbach, Elizabeth K.
    Maltz, Jonathan S.
    Gangadharan, Bijumon
    Bani-Hashemi, Ali
    Anderson, Carryn M.
    Bhatia, Sudershan K.
    Stiles, Jared
    Edwards, Drake S.
    Flynn, Ryan T.
    MEDICAL PHYSICS, 2011, 38 (11) : 5969 - 5979
  • [45] Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy
    Bian, Junguo
    Sharp, Gregory C.
    Park, Yang-Kyun
    Ouyang, Jinsong
    Bortfeld, Thomas
    El Fakhri, Georges
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09) : 3317 - 3346
  • [46] Effect of scattered radiation on image noise in cone beam CT
    Endo, M
    Tsunoo, T
    Nakamori, N
    Yoshida, K
    MEDICAL PHYSICS, 2001, 28 (04) : 469 - 474
  • [47] Development and validation of two phantoms for quality control in cone-beam CT
    Gomes Batista, Wilson Otto
    APPLIED RADIATION AND ISOTOPES, 2018, 138 : 29 - 34
  • [48] Deformable Image-Based Motion Compensation for Interventional Cone-Beam CT with a Learned Autofocus Metric
    Sisniega, A.
    Huang, H.
    Zbijewski, W.
    Stayman, J. W.
    Weiss, C. R.
    Ehtiati, T.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [49] A study on image quality provided by a kilovoltage cone-beam computed tomography
    Garayoa, Julia
    Castro, Pablo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 239 - 257
  • [50] The influence of respiratory motion on CT image volume definition
    Rodriguez-Romero, Ruth
    Castro-Tejero, Pablo
    MEDICAL PHYSICS, 2014, 41 (04)