Image quality of cone beam CT on respiratory motion

被引:0
|
作者
ZHANG Ke1 LI Minghui1 DAI Jianrong1
机构
基金
中国国家自然科学基金;
关键词
Respiratory motion; Cone beam CT; Image quality;
D O I
10.13538/j.1001-8042/nst.22.111-117
中图分类号
TP391.41 [];
学科分类号
080203 ;
摘要
In this study,the influence of respiratory motion on Cone Beam CT (CBCT) image quality was investigated by a motion simulating platform,an image quality phantom,and a kV X-ray CBCT.A total of 21 motion states in the superior-inferior direction and the anterior-posterior direction,separately or together,was simulated by considering different respiration amplitudes,periods and hysteresis.The influence of motion on CBCT image quality was evaluated with the quality indexes of low contrast visibility,geometric accuracy,spatial resolution and uniformity of CT values.The results showed that the quality indexes were affected by the motion more prominently in AP direction than in SI direction,and the image quality was affected by the respiration amplitude more prominently than the respiration period and the hysteresis.The CBCT image quality and its characteristics influenced by the respiration motion,and may be exploited in finding solutions.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [31] Evaluation of MegaVoltage Cone Beam CT image quality with an unmodified Elekta Precise Linac and EPID: a feasibility study
    Tim Markwell
    Lakshal Perera
    Jamie Trapp
    Andrew Fielding
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 291 - 302
  • [32] Evaluating iterative algebraic algorithms in terms of convergence and image quality for cone beam CT
    Qiu, W.
    Pengpan, T.
    Smith, N. D.
    Soleimani, M.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 109 (03) : 313 - 322
  • [33] Clinical introduction of image lag correction for a cone beam CT system
    Stankovic, Uros
    Ploeger, Lennert S.
    Sonke, Jan-Jakob
    van Herk, Marcel
    MEDICAL PHYSICS, 2016, 43 (03) : 1057 - 1064
  • [34] Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon®
    Lassot-Buys, Marion
    Verstraet, Rodolfe
    Dabli, Djamel
    Moliner, Gilles
    Greffier, Joel
    DIAGNOSTICS, 2023, 13 (03)
  • [35] Respiratory signal generation for retrospective gating of cone-beam CT images
    Wiesner, Stefan
    Yaniv, Ziv
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [36] Image-Based Motion Compensation for High-Resolution Extremities Cone-Beam CT
    Sisniega, A.
    Stayman, J. W.
    Cao, Q.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [37] Deformable motion compensation for interventional cone-beam CT
    Capostagno, S.
    Sisniega, A.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C. R.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05)
  • [38] Image quality improvement in cone-beam CT using the super-resolution technique
    Oyama, Asuka
    Kumagai, Shinobu
    Arai, Norikazu
    Takata, Takeshi
    Saikawa, Yusuke
    Shiraishi, Kenshiro
    Kobayashi, Takenori
    Kotoku, Jun'ichi
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (04) : 501 - 510
  • [39] Low dose cone beam CT for paediatric image-guided radiotherapy: Image quality and practical recommendations
    Bryce-Atkinson, Abigail
    De Jong, Rianne
    Marchant, Tom
    Whitfield, Gillian
    Aznar, Marianne C.
    Bel, Arjan
    van Herk, Marcel
    RADIOTHERAPY AND ONCOLOGY, 2021, 163 : 68 - 75
  • [40] Task-driven image acquisition and reconstruction in cone-beam CT
    Gang, Grace J.
    Stayman, J. Webster
    Ehtiati, Tina
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08) : 3129 - 3150