Experimental investigation of a pulse line ion accelerator in Lanzhou

被引:0
作者
申晓康 [1 ]
曹树春 [1 ]
张子民 [1 ]
景漪 [1 ]
冯玉成 [1 ]
王辉 [1 ]
赵红卫 [1 ]
赵全堂 [1 ,2 ]
刘铭 [1 ]
李中平 [1 ]
机构
[1] Institute of Modern Physics, Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
基金
中国国家自然科学基金;
关键词
PLIA; accelerator; beam experiment;
D O I
暂无
中图分类号
TL507 [加速器的运行和维修];
学科分类号
082701 ;
摘要
In order to put the Pulse Line Ion Accelerator(PLIA) concept to its practical application, a small experimental platform was built. It was found that the actual axial electric field is smaller than the theoretical calculation, so the accelerated ions will enter into the deceleration zone before leaving the helix, which will seriously affect the acceleration process. Based on the improved parameters, the He+with 24 keV is accelerated to 55 keV,and the proof-of-principle experiment is completed on this platform.
引用
收藏
页码:93 / 95
页数:3
相关论文
共 2 条
  • [1] Electric field simulation and measurement of a pulse line ion accelerator
    申晓康
    张子民
    曹树春
    赵红卫
    王博
    沈晓丽
    赵全堂
    刘铭
    景漪
    [J]. 中国物理C, 2012, (07) : 661 - 665
  • [2] The test pulse line ion accelerator in Lanzhou
    申晓康
    曹树春
    张子民
    赵红卫
    赵全堂
    刘铭
    景漪
    李中平
    万明
    王斌
    杨春名
    肖荣庆
    张应发
    李继安
    [J]. 中国物理C, 2012, (03) : 241 - 246