Endoscopic retrograde cholangiopancreatography (ERCP) is an important tool for the diagnosis and treatment of the hepatobiliary system. The use of fluoroscopy to aid ERCP places both the patient and the endoscopy staff at risk of radiation-induced injury. Radiation dose to patients during ERCP depends on many factors, and the endoscopist cannot control some variables, such as patient size, procedure type, or fluoroscopic equipment used. Previous reports have demonstrated a linear relationship between radiation dose and fluoroscopy duration. When fluoroscopy is used to assist ERCP, the shortest fluoroscopy time possible is recommended. Pulsed fluoroscopy and monitoring the length of fluoroscopy have been suggested for an overall reduction in both radiation exposure and fluoroscopy times. Fluoroscopy time is shorter when ERCP is performed by an endoscopist who has many years experience of performing ERCP and carried out a large number of ERCPs in the preceding year. In general, radiation exposure is greater during therapeutic ERCP than during diagnostic ERCP. Factors associated with prolonged fluoroscopy have been delineated recently, but these have not been validated.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 12 条
[1]  
Minimizing occupational hazards in endoscopy: personal protective equipment, radiation safety, and ergonomics[J] . Marcos C. Pedrosa,Francis A. Farraye,Amandeep K. Shergill,Subhas Banerjee,David Desilets,David L. Diehl,Vivek Kaul,Richard S. Kwon,Petar Mamula,Sarah A. Rodriguez,Shyam Varadarajulu,Louis-Michel Wong Kee Song,William M. Tierney.Gastrointestinal Endoscopy . 2010 (2)
[2]  
Prospective analysis of fluoroscopy duration during ERCP: critical determinants[J] . Edward Kim,Mark McLoughlin,Eric C. Lam,Jack Amar,Michael Byrne,Jennifer Telford,Rob Enns.Gastrointestinal Endoscopy . 2010 (1)
[3]  
Therapeutic ERCP and pregnancy: is the radiation risk for the conceptus trivial?[J] . Eleni T. Samara,John Stratakis,Jean M. Enele Melono,Ioannis A. Mouzas,Konstantinos Perisinakis,John Damilakis.Gastrointestinal Endoscopy . 2009 (4)
[4]   Comparison of safety and efficacy of ERCP performed with the patient in supine and prone positions [J].
Ferreira, Lincoln E. V. V. C. ;
Baron, Todd H. .
GASTROINTESTINAL ENDOSCOPY, 2008, 67 (07) :1037-1043
[5]  
Time-limited fluoroscopy to reduce radiation exposure during ERCP: a prospective randomized trial <ce:link locator="fx1"/>[J] . Lance T. Uradomo,Eric M. Goldberg,Peter E. Darwin.Gastrointestinal Endoscopy . 2007 (1)
[6]   Is the supine position as safe and effective as the prone position for endoscopic retrograde cholangiopancreatography? - A prospective randomized study [J].
Terruzzi, V ;
Radaelli, F ;
Meucci, G ;
Minoli, G .
ENDOSCOPY, 2005, 37 (12) :1211-1214
[7]   Effect of physician training on fluoroscopy time during ERCP [J].
Uradomo, Lance T. ;
Lustberg, Mark E. ;
Darwin, Peter E. .
DIGESTIVE DISEASES AND SCIENCES, 2006, 51 (05) :909-914
[8]   Practical radiation safety and protection for the endoscopist during ERCP [J].
Campbell, N ;
Sparrow, K ;
Fortier, M ;
Ponich, T .
GASTROINTESTINAL ENDOSCOPY, 2002, 55 (04) :552-557
[9]   Phantom study to determine radiation exposure to medical personnel involved in ERCP fluoroscopy and its reduction through equipment and behavior modifications [J].
Johlin, FC ;
Pelsang, RE ;
Greenleaf, M .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (04) :893-897
[10]   Radiation doses to patients during ERCP [J].
Larkin, CJ ;
Workman, A ;
Wright, RER ;
Tham, TCK .
GASTROINTESTINAL ENDOSCOPY, 2001, 53 (02) :161-164