Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair

被引:2
|
作者
Yang Xiao
Chen Yue-Xin
Zhang Bo
Jiang Yu-Xin
Liu Chang-Wei
Zhao Rui-Na
Wu Qiong
Zhang Da-Ming
机构
[1] Peking Union Medical College Hospital
[2] China
[3] Department of Ultrasound
[4] Chinese Academy of Medical Sciences and Peking Union Medical College
[5] Department of Radiology
[6] Department of Vascular Surgery
[7] Beijing 100730
关键词
Abdominal Aortic Aneurysm; Color Doppler Flow Imaging; Contrast-enhanced Ultrasound; Endoleak; Endovascular Aneurysm Repair;
D O I
暂无
中图分类号
R445.1 [超声波诊断]; R543.16 [];
学科分类号
1002 ; 100201 ; 100207 ;
摘要
Background: Endovascular aneurysm repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms. Postoperative endoleak is the most common complication of EVAR. Computed tomography angiography (CTA), which is routine for follow-up, has side effects (e.g., radiation) and also has a certain percentage of missed diagnosis. Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA. To investigate the advantages of CEUS, we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak.Methods: Post-EVAR patients, who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014. All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination. Size, location, microbubble dispersion, and hemodynamic characteristics of leaks were recorded. Comparison between the diagnosis of CEUS and CDFI was conducted using Fisher’s exact test and clinical outcomes of all patients were followed up.Results: Sixteen patients were enrolled, and 12 (75%) had endoleaks with verified types by CEUS. Among 12 cases of endoleaks were positive by CEUS, 10 were CDFI-positive, and the four CEUS-negative cases were all negative by CDFI. The diagnostic values of CEUS and CDFI were statistically different (P = 0.008). Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results. One patient with type III endoleak had open surgery when endovascular repair failed.Conclusions: CEUS is a new, safe, and effective means for detection of endoleaks post-EVAR. This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category.
引用
收藏
页码:2491 / 2497
页数:7
相关论文
共 50 条
  • [41] Endovascular treatment of endoleaks after endovascular abdominal aortic aneurysm repair: Personal experience
    Pozzi Mucelli F.
    Doddi M.
    Bruni S.
    Adovasio R.
    Pancrazio F.
    Cova M.
    La radiologia medica, 2007, 112 (3) : 409 - 419
  • [42] Cost-effectiveness of contrast-enhanced ultrasound for the detection of endovascular aneurysm repair-related endoleaks requiring treatment
    Froelich, Matthias F.
    Kunz, Wolfgang G.
    Kim, Su Hwan
    Sommer, Wieland H.
    Clevert, Dirk-Andre
    Ruebenthaler, Johannes
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (01) : 232 - +
  • [43] Treatment of endoleaks after endovascular abdominal aorta aneurysm repair
    Duman, Enes
    Cifci, Egemen
    Yildirim, Erkan
    Boyvat, Fatih
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 24 (03): : 569 - 572
  • [44] Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair
    Iezzi, Roberto
    Basilico, Raffaella
    Giancristofaro, Daniela
    Pascali, Danilo
    Cotroneo, Antonio Raffaele
    Storto, Maria Luigia
    JOURNAL OF VASCULAR SURGERY, 2009, 49 (03) : 552 - 560
  • [45] Contrast-Enhanced ultrasound in endovascular aneurysm repair follow-up: Our experience
    Busoni, Cristina
    Frigerio, Dalmazio
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 7 (03) : 237 - 240
  • [46] Intraoperative contrast-enhanced ultrasound examination for endoleak detection after complex and infrarenal endovascular aortic repair
    Keschenau, Paula R.
    Alkassam, Hussam
    Kotelis, Drosos
    Jacobs, Michael J.
    Kalder, Johannes
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (04) : 1200 - 1206
  • [47] Clinical significance of endoleaks characterized by computed tomography during aortography performed immediately after endovascular abdominal aortic aneurysm repair: prediction of persistent endoleak
    Nakai, Motoki
    Sato, Hirotatsu
    Sato, Morio
    Tanba, Yuko
    Noda, Yasutaka
    Ikoma, Akira
    Sanda, Hiroki
    Nakata, Kohei
    Minamiguchi, Hiroki
    Kawai, Nobuyuki
    Sonomura, Tetsuo
    Kishi, Kazushi
    Nishimura, Yosiharu
    Okamura, Yoshitaka
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (01) : 16 - 23
  • [48] Clinical significance of endoleaks characterized by computed tomography during aortography performed immediately after endovascular abdominal aortic aneurysm repair: prediction of persistent endoleak
    Motoki Nakai
    Hirotatsu Sato
    Morio Sato
    Yuko Tanba
    Yasutaka Noda
    Akira Ikoma
    Hiroki Sanda
    Kohei Nakata
    Hiroki Minamiguchi
    Nobuyuki Kawai
    Tetsuo Sonomura
    Kazushi Kishi
    Yosiharu Nishimura
    Yoshitaka Okamura
    Japanese Journal of Radiology, 2013, 31 : 16 - 23
  • [49] Endoleaks After Endovascular Abdominal Aortic Aneurysm Repair: Management Strategies According to CT Findings
    Bashir, Mustafa R.
    Ferral, Hector
    Jacobs, Chad
    McCarthy, Walter
    Goldin, Marshall
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : W178 - W186
  • [50] Comparison of contrast-enhanced ultrasound and compression elastography in the follow-up after endovascular aortic aneurysm repair
    Guertler, V. M.
    Rjosk-Dendorfer, D.
    Reiser, M.
    Clevert, D. A.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2014, 57 (02) : 175 - 183