Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair

被引:2
|
作者
Yang Xiao
Chen Yue-Xin
Zhang Bo
Jiang Yu-Xin
Liu Chang-Wei
Zhao Rui-Na
Wu Qiong
Zhang Da-Ming
机构
[1] Peking Union Medical College Hospital
[2] China
[3] Department of Ultrasound
[4] Chinese Academy of Medical Sciences and Peking Union Medical College
[5] Department of Radiology
[6] Department of Vascular Surgery
[7] Beijing 100730
关键词
Abdominal Aortic Aneurysm; Color Doppler Flow Imaging; Contrast-enhanced Ultrasound; Endoleak; Endovascular Aneurysm Repair;
D O I
暂无
中图分类号
R445.1 [超声波诊断]; R543.16 [];
学科分类号
1002 ; 100201 ; 100207 ;
摘要
Background: Endovascular aneurysm repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms. Postoperative endoleak is the most common complication of EVAR. Computed tomography angiography (CTA), which is routine for follow-up, has side effects (e.g., radiation) and also has a certain percentage of missed diagnosis. Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA. To investigate the advantages of CEUS, we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak.Methods: Post-EVAR patients, who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014. All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination. Size, location, microbubble dispersion, and hemodynamic characteristics of leaks were recorded. Comparison between the diagnosis of CEUS and CDFI was conducted using Fisher’s exact test and clinical outcomes of all patients were followed up.Results: Sixteen patients were enrolled, and 12 (75%) had endoleaks with verified types by CEUS. Among 12 cases of endoleaks were positive by CEUS, 10 were CDFI-positive, and the four CEUS-negative cases were all negative by CDFI. The diagnostic values of CEUS and CDFI were statistically different (P = 0.008). Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results. One patient with type III endoleak had open surgery when endovascular repair failed.Conclusions: CEUS is a new, safe, and effective means for detection of endoleaks post-EVAR. This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category.
引用
收藏
页码:2491 / 2497
页数:7
相关论文
共 50 条
  • [31] Endoleaks after endovascular repair of abdominal aortic aneurysm: value of CEUS
    R. Iezzi
    A. R. Cotroneo
    R. Basilico
    A. Simeone
    M. L. Storto
    L. Bonomo
    Abdominal Imaging, 2010, 35 : 106 - 114
  • [32] Associated gastroduodenal artery aneurysm aortic aneurysm: the diagnostic contribution of contrast-enhanced ultrasound in correlation with computed tomography angiography
    Radu Badea
    Liliana Chiorean
    Olimpia Chira
    Cosmin Caraiani
    Journal of Medical Ultrasonics, 2014, 41 : 217 - 221
  • [33] Associated gastroduodenal artery aneurysm aortic aneurysm: the diagnostic contribution of contrast-enhanced ultrasound in correlation with computed tomography angiography
    Badea, Radu
    Chiorean, Liliana
    Chira, Olimpia
    Caraiani, Cosmin
    JOURNAL OF MEDICAL ULTRASONICS, 2014, 41 (02) : 217 - 221
  • [34] Dynamic Volumetric Computed Tomography Angiography Is a Preferred Method for Unclassified Endoleaks by Conventional Computed Tomography Angiography After Endovascular Aortic Repair
    Hou, Kai
    Zhu, Ting
    Zhang, Wei
    Zeng, Mengsu
    Guo, Daqiao
    Fu, Weiguo
    Si, Yi
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (08):
  • [35] Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm
    Choi, Sun Young
    Won, Jong Yun
    Lee, Do Yun
    Choi, Donghoon
    Shim, Won-Heum
    Lee, Kwang-Hun
    KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (01) : 107 - 114
  • [36] Follow up of endovascular abdominal aortic aneurysm repair with contrast ultrasound
    Deklunder, G.
    Sediri, I.
    Donati, T.
    Boivin, V.
    Gautier, C.
    Haulon, S.
    JOURNAL DE RADIOLOGIE, 2009, 90 (01): : 141 - 147
  • [37] The usefulness of contrast-enhanced subtraction magnetic resonance imaging for detecting endoleaks after endovascular aortic repair with prophylactic intraoperative sac embolization
    Kamisako, Atsufumi
    Nakai, Motoki
    Saguchi, Toru
    Tanaka, Taro
    Okada, Yukinori
    Ishida, Masanori
    Saito, Kazuhiro
    ACTA RADIOLOGICA, 2024, 65 (10) : 1205 - 1210
  • [38] Single-centre Prospective Comparison Between Contrast-Enhanced Ultrasound and Computed Tomography Angiography after EVAR
    Perini, P.
    Sediri, I.
    Midulla, M.
    Delsart, P.
    Mouton, S.
    Gautier, C.
    Pruvo, J-P.
    Haulon, S.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 (06) : 797 - 802
  • [39] Endovascular treatment of endoleaks after endovascular abdominal aortic aneurysm repair: personal experience
    Pozzi Mucelli, F.
    Doddi, M.
    Bruni, S.
    Adovasio, R.
    Pancrazio, F.
    Cova, M.
    RADIOLOGIA MEDICA, 2007, 112 (03): : 409 - 419
  • [40] Effect of endoleaks on changes in aortoiliac volume after endovascular repair for abdominal aortic aneurysm
    Meinel, Felix G.
    Haack, Mareike
    Weidenhagen, Rolf
    Hellbach, Katharina
    Rottenkolber, Marietta
    Armbruster, Marco
    Jerkku, Thomas
    Thierfelder, Kolja M.
    Pluma, Jessica L. V.
    Koeppelb, Thomas A.
    Rubind, Geoffrey D.
    Sommera, Wieland H.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 64 (02) : 135 - 147