Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair

被引:2
|
作者
Yang Xiao
Chen Yue-Xin
Zhang Bo
Jiang Yu-Xin
Liu Chang-Wei
Zhao Rui-Na
Wu Qiong
Zhang Da-Ming
机构
[1] Peking Union Medical College Hospital
[2] China
[3] Department of Ultrasound
[4] Chinese Academy of Medical Sciences and Peking Union Medical College
[5] Department of Radiology
[6] Department of Vascular Surgery
[7] Beijing 100730
关键词
Abdominal Aortic Aneurysm; Color Doppler Flow Imaging; Contrast-enhanced Ultrasound; Endoleak; Endovascular Aneurysm Repair;
D O I
暂无
中图分类号
R445.1 [超声波诊断]; R543.16 [];
学科分类号
1002 ; 100201 ; 100207 ;
摘要
Background: Endovascular aneurysm repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms. Postoperative endoleak is the most common complication of EVAR. Computed tomography angiography (CTA), which is routine for follow-up, has side effects (e.g., radiation) and also has a certain percentage of missed diagnosis. Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA. To investigate the advantages of CEUS, we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak.Methods: Post-EVAR patients, who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014. All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination. Size, location, microbubble dispersion, and hemodynamic characteristics of leaks were recorded. Comparison between the diagnosis of CEUS and CDFI was conducted using Fisher’s exact test and clinical outcomes of all patients were followed up.Results: Sixteen patients were enrolled, and 12 (75%) had endoleaks with verified types by CEUS. Among 12 cases of endoleaks were positive by CEUS, 10 were CDFI-positive, and the four CEUS-negative cases were all negative by CDFI. The diagnostic values of CEUS and CDFI were statistically different (P = 0.008). Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results. One patient with type III endoleak had open surgery when endovascular repair failed.Conclusions: CEUS is a new, safe, and effective means for detection of endoleaks post-EVAR. This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category.
引用
收藏
页码:2491 / 2497
页数:7
相关论文
共 50 条
  • [21] ARTIFACTS IN CONTRAST-ENHANCED ULTRASOUND DURING FOLLOW-UP AFTER ENDOVASCULAR AORTIC REPAIR: IMPACT ON ENDOLEAK DETECTION IN COMPARISON WITH COMPUTED TOMOGRAPHY ANGIOGRAPHY
    Frenzel, Felix
    Kubale, Reinhard
    Massmann, Alexander
    Raczeck, Paul
    Jagoda, Philippe
    Schlueter, Christian
    Stroeder, Jonas
    Buecker, Arno
    Minko, Peter
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03) : 488 - 498
  • [22] Role of multidetector CT angiography and contrast-enhanced ultrasound in redefining follow-up protocols after endovascular abdominal aortic aneurysm repair
    Motta, R.
    Rubaltelli, L.
    Vezzaro, R.
    Vida, V.
    Marchesi, P.
    Stramare, R.
    Zanon, A.
    Battistel, M.
    Sommavilla, M.
    Miotto, D.
    RADIOLOGIA MEDICA, 2012, 117 (06): : 1079 - 1092
  • [23] Role of multidetector CT angiography and contrast-enhanced ultrasound in redefining follow-up protocols after endovascular abdominal aortic aneurysm repair
    Motta, R.
    Rubaltelli, L.
    Vezzaro, R.
    Vida, V.
    Marchesi, P.
    Stramare, R.
    Zanon, A.
    Battistel, M.
    Sommavilla, M.
    Miotto, D.
    RADIOLOGIA MEDICA, 2012, 117 (06): : 1079 - 1092
  • [24] Contrast Enhancement Boost Technique at Aortic Computed Tomography Angiography: Added Value for the Evaluation of Type II Endoleaks After Endovascular Aortic Aneurysm Repair
    Iizuka, Hitoshi
    Yokota, Yasuhiro
    Kidoh, Masafumi
    Oda, Seitaro
    Ikeda, Osamu
    Tamura, Yoshitaka
    Funama, Yoshinori
    Sakabe, Daisuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    Utsunomiya, Daisuke
    ACADEMIC RADIOLOGY, 2019, 26 (11) : 1435 - 1440
  • [25] Is Abdominal Aortic Aneurysm Behavior after Endovascular Repair Associated with Aneurysm Wall Density on Computed Tomography Angiography?
    Skrebunas, Arminas
    Lengvenis, Givi
    Builyte, Inga Urte
    Zulpaite, Ruta
    Bliudzius, Rytis
    Purlys, Petras
    Baltrunas, Tomas
    Misonis, Nerijus
    Mataciunas, Mindaugas
    Marinskis, Germanas
    Vajauskas, Donatas
    MEDICINA-LITHUANIA, 2019, 55 (08):
  • [26] Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS). A pictorial comparison with CTA
    Clevert, D. -A.
    Minaifar, N.
    Kopp, R.
    Stickel, M.
    Meimarakis, G.
    Sommer, W.
    Reiser, M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 41 (03) : 151 - 168
  • [27] Analysis of Outcomes After Endovascular Abdominal Aortic Aneurysm Repair in Patients With Abnormal Findings on the First Postoperative Computed Tomography Angiography
    Geraedts, Anna C. M.
    Mulay, Sana
    van Dieren, Susan
    Koelemay, Mark J. W.
    Balm, Ron
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (06) : 878 - 887
  • [28] Aneurysm Wall Enhancement Detected by Contrast Computed Tomography Scan Is Associated With Aneurysm Shrinkage After Endovascular Aneurysm Repair for Abdominal Aortic Aneurysm
    Ito, Eisaku
    Toya, Naoki
    Fukushima, Soichiro
    Murakami, Yuri
    Akiba, Tadashi
    Ohki, Takao
    CIRCULATION JOURNAL, 2018, 82 (02) : 340 - 345
  • [29] Endovascular aneurysm repair follow-up by unenhanced and contrast-enhanced duplex ultrasound
    Sarlon, G.
    Lapierre, F.
    Sarlon, E.
    Bartoli, M. -A.
    Magnan, P. E.
    Branchereau, A.
    JOURNAL DES MALADIES VASCULAIRES, 2009, 34 (01) : 34 - 43
  • [30] Contrast-enhanced ultrasound detects type II endoleaks during follow-up for endovascular aneurysm repair
    Johnsen, Lydia
    Hisdal, Jonny
    Jonung, Torbjorn
    Braaten, Audun
    Pedersen, Gustav
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (06) : 1952 - 1959