Using computed tomography scans to develop an ex-vivo gastric model

被引:0
作者
Jerome A Henry
Gerard O’Sullivan
Abhay S Pandit
机构
[1] Department of Mechanical and Biomedical Engineering and National Centre for Biomedical Engineering Science National University of Ireland Galway Ireland
[2] Department of Mechanical and Biomedical Engineering and National Centre for Biomedical Engineering Science National University of Ireland Galway Ireland
[3] Department of Radiology University College Hospital Galway
[4] Section of Interventional Radiology
关键词
Gastric anthropometrical data; Rapid prototyping; Ex-vivo gastric model; Computed tomography;
D O I
暂无
中图分类号
R816.5 [腹部及消化系];
学科分类号
1001 ; 100105 ; 100207 ; 100602 ;
摘要
The objective of this research was to use abdominal computed tomography (CT) scans to non-invasively quantify anthropometrical data of the human stomach and to concomitantly create an anatomically correct and distensible ex-vivo gastric model. Thirty-three abdominal CT scans of human subjects were obtained and were imported into reconstruction software to generate 3D models of the stomachs. Anthropometrical data such as gastric wall thickness, gastric surface area and gastric volume were subsequently quantified. A representative 3D computer model was exported into a selective laser sintering (SLS) rapid prototyping machine to create an anatomically correct solid gastric model. Subsequently, a replica wax template of the SLS model was created. A negative mould was offset around the wax template such that the offset distance was equivalent to that of the gastric wall thickness. A silicone with similar mechanical properties to the human stomach was poured into the offset. The lost wax manufacturing technique was employed to create a hollow distensible stomach model. 3D computer gastric models were generated from the CT scans. A hollow distensible silicone ex-vivo gastric model with similar compliance to that of the human stomach was created. The anthropometrical data indicated that there is no significant relationship between BMI and gastric surface area or gastric volume. There were inter- and intra-group differences between groups with respect to gastric wall thickness. This study demonstrates that abdominal CT scans can be used to both non-invasively determine gastric anthropometrical data as well as create realistic ex-vivo stomach models.
引用
收藏
页码:1372 / 1377
页数:6
相关论文
共 1 条
  • [1] Use of water or air as oral contrast media for computed tomographic study of the gastric wall: Comparison of the two techniques[J] . Konstantinos J. Gossios,Epameinondas V. Tsianos,Lefkothea L. Demou,Christos K. Tatsis,Vasilios P. Papakostas,Constantine N. Masalas,Markos Ch. Merkouropoulos,Demetrios S. Kontogiannis.Gastrointestinal Radiology . 1991 (1)