An X-ray imaging device based on a GEM detector with delay-line readout

被引:1
|
作者
周意 [1 ]
李澄 [1 ]
孙勇杰 [1 ]
邵明 [1 ]
机构
[1] Department of Modern Physics, University of Science and Technology of China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TL816.1 [];
学科分类号
摘要
An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the top and 250 μm width on the bottom, is designed and tested. The localization information is derived from the propagation time of the induced signals on the readout strips. This device has a good spatial resolution of 150 μm and works stably at an intensity of 105 Hz/mm2 with 8 keV X-rays.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 50 条
  • [1] An X-ray imaging device based on a GEM detector with delay-line readout
    Zhou Yi
    Li Cheng
    Sun Yong-Jie
    Shao Ming
    CHINESE PHYSICS C, 2010, 34 (01) : 78 - 82
  • [2] Study of delay-line readout for GEM detector
    Zhou, Yi
    Li, Cheng
    Sun, Yongjie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 71 - 76
  • [3] Two-dimensional GEM imaging detector with delay-line readout
    Guedes, GP
    Breskin, A
    Chechik, R
    Vartsky, D
    Bar, D
    Barbosa, AF
    Marinho, PRB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03): : 473 - 483
  • [4] A prototype of X-ray imaging device based on the GEM detector
    Li, C
    Yi, SYJZ
    An, SL
    Xu, ZZ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (01): : 68 - 71
  • [5] Research on the delay-line readout for GEM detectors
    Zhou Yi
    Li Cheng
    CHINESE PHYSICS C, 2008, 32 : 232 - 234
  • [6] A HIGH-COUNT RATE AREA DETECTOR WITH MULTIPLE DELAY-LINE READOUT FOR X-RAY CRYSTALLOGRAPHY
    KOIKE, M
    HASEGAWA, K
    MOCHIKI, K
    OGAWA, T
    HASHIZUME, H
    IITAKA, Y
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C411 - C411
  • [7] A MICROSTRIP DETECTOR WITH DELAY-LINE READOUT
    BARBOSA, AF
    RIEKEL, C
    WATTECAMPS, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 667 - 669
  • [8] X-ray imaging demonstration of glass GEM detector with dynamic time-over-threshold-based readout
    Mitsuya, Y.
    Fujiwara, T.
    Takahashi, H.
    Uesakaa, M.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [9] Fabrication and Signal Readout of the Si-based Delay-line Radiation Detector
    Jeong, Manhee
    Ramadoss, Subhashree
    Hammig, Mark D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1666 - +
  • [10] FPGA implementation of a delay-line readout system for a particle detector
    Seferiadis, G
    Pouchet, M
    Gough, MP