Model of Current Threshold for Perception in Testing Electrical Safety Performance
被引:0
作者:
王晓飞
[1
,2
]
张朝晖
[1
]
李东
[2
]
刘国忠
[2
]
赵旭
[3
]
机构:
[1] School of Information Engineering, University of Science and Technology Beijing
[2] School of Electro-Optical Engineering, Beijing Information Science and Technology University
[3] Department of Neurology, The th Hospital of PLA
关键词:
electrical safety performance;
leakage current;
current threshold for perception;
current waveform;
electroencephalogram(EEG);
D O I:
暂无
中图分类号:
TM933.1 [电流测量及仪表];
学科分类号:
080802 ;
摘要:
A generalized mathematical model of human body current threshold for perception was established and the current flowing through human body could be arbitrary cyclical waveforms.The relationship between human body current threshold for perception and current frequency, true root mean square(RMS) value and influence factor was described.A test system was established based on electroencephalogram(EEG) to study the relationship between human body current threshold for perception and current waveform, frequency and duty cycle so that the data could be obtained objectively and reliably.At least 850 groups of current threshold for perception and 16-lead EEGs were acquired.The theoretical analysis are verified by experimental data, and an amendment proposal on leakage current evaluation limits specified in International Electro-Technical Commission(IEC) standards is suggested.