Energy performance assessment on central air-conditioning system of commercial building: A case study in China

被引:1
作者
周璇 [1 ,2 ]
练斯甄 [1 ,2 ]
闫军威 [1 ,2 ]
康英姿 [1 ,2 ]
机构
[1] School of Mechanical & Automotive Engineering, South China University of Technology
[2] City Air-conditioning Energy Conservation and Control Project Technology Research Exploitation Center of Guangdong
关键词
energy performance assessment; thermal comfort; indoor air quality; central air-conditioning system; energy saving;
D O I
暂无
中图分类号
TU831 [空气调节];
学科分类号
080705 ;
摘要
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.
引用
收藏
页码:3168 / 3179
页数:12
相关论文
共 7 条
[1]  
Coupled simulation of BES-CFD and performance assessment of energy recovery ventilation system for office model[J]. T.Hayashi,K.Ito. Journal of Central South University. 2012(03)
[2]   广州公共建筑能耗调查及研究 [J].
周孝清 ;
刘芳 ;
陈伟青 ;
杨树荣 ;
丁云飞 .
建筑科学, 2007, (12) :76-80
[3]   长沙市公共建筑空调系统能耗现状与节能潜力分析 [J].
杨昌智 ;
吴晓艳 ;
李文菁 ;
戴小珍 .
暖通空调, 2005, (12) :39-43+109
[4]  
Co-optimisation of indoor environmental quality and energy consumption within urban office buildings[J] . Tran Ngoc Quang,Congrong He,Luke D. Knibbs,Richard de Dear,Lidia Morawska. Energy & Buildings . 2014
[5]  
Study on energy saving possibility of digital variable multiple air conditioning system in three office buildings in Shanghai[J] . Dongliang Zhang,Xu Zhang,Ning Cai. Energy & Buildings . 2014
[6]  
Energy performance assessment and a retrofit strategies in public school buildings in Rome[J] . L. de Santoli,F. Fraticelli,F. Fornari,C. Calice. Energy & Buildings . 2014
[7]  
Design standard for energy efficiency of public\sbuildings .2 DBJ 15-51—2007 .